Fluctuation of an ion beam extracted from an AC filament driven Bernas-type ion source

被引:1
|
作者
Miyamoto, N. [1 ]
Okajima, Y. [1 ]
Wada, M. [1 ]
机构
[1] Doshisha Univ, Grad Sch Sci & Engn, Kyoto 6100321, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2014年 / 85卷 / 02期
关键词
D O I
10.1063/1.4830356
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Argon ion beam fluctuation from an AC filament driven Bernas-type ion source is observed. The ion beam was measured by an 8 measurement elements beam profile monitor. The amplitude of the beam current fluctuation stayed in the same level from 100 Hz to 1 kHz of the filament heating frequency. The beam current fluctuation frequency measured by the beam profile monitor was equal to the frequency of the AC filament operation. The fluctuation amplitudes of the beam current by AC operation were less than 7% and were in the same level of the DC operation. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Ion beam extracted from a 14GHz ECRIS of CAPRICE type
    Spaedtke, P.
    Lang, R.
    Maeder, J.
    Rossbach, J.
    Tinschert, K.
    Stetson, J.
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2007, 31 : 192 - 195
  • [42] CHARACTERISTICS OF THE NEGATIVE-ION BEAM EXTRACTED FROM AN LBL MULTICUSP VOLUME SOURCE
    DEBIAK, TW
    SOLENSTEN, L
    SREDNIAWSKI, JJ
    NG, YC
    HEUER, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (01): : 392 - 394
  • [43] Spatiotemporal oscillation of an ion beam extracted from a potential-oscillating plasma source
    Takahashi, Kazunori
    Imagi, Tsuyoshi
    Ishitomi, Masashi
    Nagaoka, Kenichi
    Haba, Yasuaki
    Nakano, Haruhisa
    Ando, Akira
    Kisaki, Masashi
    Tsumori, Katsuyoshi
    Ikeda, Katsunori
    NEW JOURNAL OF PHYSICS, 2019, 21 (09):
  • [44] Effect of plasma density on high current beam extracted from a MEVVA ion source
    Xiang, W.
    Spaedtke, P.
    2007 IEEE PULSED POWER CONFERENCE, VOLS 1-4, 2007, : 79 - +
  • [45] Study on the energy distribution of ion beams extracted from the sputter-type negative-ion source
    Ishikawa, J
    Tsuji, H
    Takatori, T
    Gotoh, Y
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS / PRODUCTION AND APPLICATION OF LIGHT NEGATIVE IONS, 1996, (380): : 241 - 251
  • [46] Plasma Electrode Structure Suitable for H- Extraction form Bernas Type Ion Source
    Ishikawa, M.
    Oura, K.
    Miyamoto, N.
    Wada, M.
    SIXTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2018), 2018, 2052
  • [47] LONG LIFE PLASMA FILAMENT TYPE ION-SOURCE
    FUKUI, R
    TAKAGI, K
    TSUGUEDA, T
    TSUBOI, H
    KIKUCHI, R
    YABE, E
    TAKAYAMA, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 37-8 : 140 - 142
  • [48] A study of VUV emission and the extracted electron-ion ratio in hydrogen and deuterium plasmas of a filament-driven H-/D- ion source
    Komppula, J.
    Tarvainen, O.
    Kalvas, T.
    Koivisto, H.
    Myllyperkio, P.
    Toivanen, V
    PHYSICS OF PLASMAS, 2019, 26 (07)
  • [49] Characteristics of ion beams extracted from a compact powdery sample ion source
    Wada, M
    Kasuya, T
    Sasao, M
    Kawano, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 719 - 721
  • [50] Measurement of excess energies of ion beams extracted from a microwave ion source
    Sakudo, N
    Hayashi, K
    Yokota, J
    Kawasaki, A
    Ikenaga, N
    Sakaguchi, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 136 : 793 - 797