Fluctuation of an ion beam extracted from an AC filament driven Bernas-type ion source

被引:1
|
作者
Miyamoto, N. [1 ]
Okajima, Y. [1 ]
Wada, M. [1 ]
机构
[1] Doshisha Univ, Grad Sch Sci & Engn, Kyoto 6100321, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2014年 / 85卷 / 02期
关键词
D O I
10.1063/1.4830356
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Argon ion beam fluctuation from an AC filament driven Bernas-type ion source is observed. The ion beam was measured by an 8 measurement elements beam profile monitor. The amplitude of the beam current fluctuation stayed in the same level from 100 Hz to 1 kHz of the filament heating frequency. The beam current fluctuation frequency measured by the beam profile monitor was equal to the frequency of the AC filament operation. The fluctuation amplitudes of the beam current by AC operation were less than 7% and were in the same level of the DC operation. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Theoretical and experimental studies of the extracted MCI beam from an ECR ion source
    Sun, LT
    Cao, Y
    Zhao, HW
    Guo, XH
    Zhang, ZM
    Feng, YC
    Li, JY
    Ma, L
    Li, J
    Zhao, HY
    He, W
    Li, XX
    Hitz, D
    Girard, A
    Electron Cyclotron Resonance Ion Sources, 2005, 749 : 227 - 230
  • [32] POSSIBILITY OF USING A SOURCE OF BERNAS-NIER TYPE FOR NEGATIVE-ION PRODUCTION
    DENIMAL, J
    RICAUD, C
    NUCLEAR INSTRUMENTS & METHODS, 1973, 109 (02): : 409 - 409
  • [33] Contribution of atomic hydrogen flux on H- ion beam extracted from a negative hydrogen ion source
    Shimabukuro, Yuji
    Kuwahara, Daisuke
    Wada, Motoi
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2018, 2011
  • [34] Characteristics of extracted ion beam from a cesium-free negative ion source using sheet plasma
    Kaminaga, H.
    Takimoto, T.
    Tonegawa, A.
    Sato, K. N.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (11):
  • [35] Beam extraction from a laser-driven multicharged ion source
    Anderson, OA
    Logan, BG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 1106 - 1106
  • [36] Beam extraction from a laser-driven multicharged ion source
    Anderson, O.A.
    Logan, B. Grant
    Review of Scientific Instruments, 1998, 69 (2 pt 2):
  • [37] Nitriding with ion beam from Hall-type source
    Bacal, M
    Peyre, JP
    APPLIED SURFACE SCIENCE, 1999, 138 : 155 - 158
  • [38] Extracted Beam and Electrode Currents in the Inductively Driven Surface-Plasma Negative Hydrogen Ion Source
    Belchenko, Yu.
    Ivanov, A.
    Sanin, A.
    Sotnikov, O.
    FIFTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2016), 2017, 1869
  • [39] SOME PROPERTIES OF ION BEAM FROM A SOURCE OF DUOPLASMATRON TYPE
    SEPTIER, A
    PRANGERE, F
    ISMAIL, H
    GAUTHERI.G
    NUCLEAR INSTRUMENTS & METHODS, 1965, 38 (DEC): : 41 - &
  • [40] Increase of Boron Ion Beam Current Extracted from a Multi-Cusp Ion Source in an Ion Doping System with Mass Separation
    Inouchi, Yutaka
    Dohi, Shojiro
    Tanii, Masahiro
    Tatemichi, Junichi
    Konishi, Masashi
    Nukayama, Masaaki
    Nakao, Kazuhiro
    Orihira, Koichi
    Naito, Masao
    ION IMPLANTATION TECHNOLOGY 2008, 2008, 1066 : 316 - 319