Plasma Electrode Structure Suitable for H- Extraction form Bernas Type Ion Source

被引:1
|
作者
Ishikawa, M. [1 ]
Oura, K. [1 ]
Miyamoto, N. [1 ]
Wada, M. [1 ]
机构
[1] Doshisha Univ, Grad Sch Sci & Engn, Kyoto 6100321, Japan
关键词
D O I
10.1063/1.5083778
中图分类号
O59 [应用物理学];
学科分类号
摘要
The plasma electrode stnicture of a Bernas type ion source was modified to increase negative hydrogen (H-) ion current. On the previous geometry the plasma electrodes was installed inside the ion source while the new geometry has the plasma electrode outside discharge chamber. The It ion beam current increased by positively biasing the plasma electrode to improve the ratio of the negative ion current and the extraction current to 2.4 times the original ratio for the electrode installed inside. The It ion beam current increased 1.2 times enhancement by tantalum (Ta) filament was also attempted. The Ta filament produce 20 % more H- ion current and reduced extraction current by 50 %. The overall improvement by plasma electrode structure and Ta filament made the it ion to extraction current ratio to double.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Plasma meniscus and extraction electrode studies of the ISIS H- ion source
    Lawrie, S. R.
    Faircloth, D. C.
    Letchford, A. P.
    Gabor, C.
    Pozimski, J. K.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02):
  • [2] Wave frequency dependence of H- ion production and extraction in a transformer coupled plasma H- ion source at SNU
    An, YoungHwa
    Cho, WonHwi
    Chung, Kyoung-Jae
    Lee, Kern
    Jang, SeungBin
    Lee, Seok-Geun
    Hwang, Y. S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [3] A new plasma H- ion source
    Litvinov, PA
    Savchenko, IS
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS / PRODUCTION AND APPLICATION OF LIGHT NEGATIVE IONS, 1996, (380): : 272 - 280
  • [4] Measurements of H- density and work function of a plasma electrode in a negative ion source
    Nishiura, M
    Sasao, M
    Wada, M
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS, 2002, 639 : 21 - 27
  • [5] DIRECT EXTRACTION H- ION-SOURCE
    ALLISON, PW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (02): : 175 - 175
  • [6] DIRECT EXTRACTION H- ION-SOURCE
    ALLISON, PW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (03) : 1594 - 1596
  • [7] H- ion beam extraction from a transformer coupled plasma source with triode extraction system
    Jeong, HS
    Kim, YJ
    Hong, IS
    Park, DH
    Hwang, YS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03):
  • [8] Studies on the extraction region of the type VI RF driven H- ion source
    McNeely, P
    Bandyopadhyay, M
    Franzen, P
    Heinemann, B
    Hu, C
    Kraus, W
    Riedl, R
    Speth, E
    Wilhelm, R
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS, 2002, 639 : 90 - 111
  • [9] Detailed beam and plasma measurements on the vessel for extraction and source plasma analyses (VESPA) Penning H- ion source
    Lawrie, S. R.
    Faircloth, D. C.
    Letchford, A. P.
    Whitehead, M. O.
    Wood, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [10] Influence of H- velocity on H- extraction probability from a negative ion source
    Matsumoto, Y.
    Nishiura, M.
    Shinto, K.
    Yamaoka, H.
    Sasao, M.
    Wada, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02):