Plasma Electrode Structure Suitable for H- Extraction form Bernas Type Ion Source

被引:1
|
作者
Ishikawa, M. [1 ]
Oura, K. [1 ]
Miyamoto, N. [1 ]
Wada, M. [1 ]
机构
[1] Doshisha Univ, Grad Sch Sci & Engn, Kyoto 6100321, Japan
关键词
D O I
10.1063/1.5083778
中图分类号
O59 [应用物理学];
学科分类号
摘要
The plasma electrode stnicture of a Bernas type ion source was modified to increase negative hydrogen (H-) ion current. On the previous geometry the plasma electrodes was installed inside the ion source while the new geometry has the plasma electrode outside discharge chamber. The It ion beam current increased by positively biasing the plasma electrode to improve the ratio of the negative ion current and the extraction current to 2.4 times the original ratio for the electrode installed inside. The It ion beam current increased 1.2 times enhancement by tantalum (Ta) filament was also attempted. The Ta filament produce 20 % more H- ion current and reduced extraction current by 50 %. The overall improvement by plasma electrode structure and Ta filament made the it ion to extraction current ratio to double.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Simulation of H- ion source extraction systems for the Spallation Neutron Source with Ion Beam Simulator
    Kalvas, T.
    Welton, R. F.
    Tarvainen, O.
    Han, B. X.
    Stockli, M. P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [22] CONTINUOUS OPERATED H- SURFACE PLASMA ION-SOURCE
    PIOSCZYK, B
    DAMMERTZ, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (05): : 840 - 846
  • [23] Compact surface plasma H- ion source with geometrical focusing
    Dudnikov, V.
    Dudnikova, G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [24] H- ion source using a localized virtual magnetic filter in the plasma electrode:: Type-I localized virtual magnetic filter
    Oka, Y
    Kaneko, O
    Tsumori, K
    Takeiri, Y
    Osakabe, M
    Kawamoto, T
    Asano, E
    Akiyama, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 693 - 695
  • [25] Enhancement of H-/D- volume production in a double plasma type negative ion source
    Fukumasa, O
    Nishimura, H
    Sakiyama, S
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS / PRODUCTION AND APPLICATION OF LIGHT NEGATIVE IONS, 1996, (380): : 288 - 299
  • [26] Response of H- ions to extraction field in a negative hydrogen ion source
    Geng, S.
    Tsumori, K.
    Nakano, H.
    Kisaki, M.
    Ikeda, K.
    Osakabe, M.
    Nagaoka, K.
    Takeiri, Y.
    Shibuya, M.
    FUSION ENGINEERING AND DESIGN, 2017, 123 : 481 - 484
  • [27] Negative Hydrogen Ion Beam Extraction from an AC Heated Cathode Driven Bernas-Type Ion Source
    Okano, Y.
    Miyamoto, N.
    Kasuya, T.
    Wada, M.
    FOURTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2014), 2015, 1655
  • [28] Optimization and numerical simulation for the extraction system of the H- multicusp ion source
    Hosseinzadeh, M.
    Afarideh, H.
    CHINESE PHYSICS C, 2014, 38 (05)
  • [29] A new extraction system for the Linac4 H- ion source
    Midttun, O.
    Kalvas, T.
    Kronberger, M.
    Lettry, J.
    Pereira, H.
    Schmitzer, C.
    Scrivens, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [30] Plasma electrode bias effect on the H- negative-ion density in an electron cyclotron resonance volume source
    Svarnas, Panagiotis
    Breton, Jacques
    Bacal, Marthe
    Faulkner, Ronan
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2007, 35 (04) : 1156 - 1162