Carotid artery flow as determined by real-time phase-contrast flow MRI and neurovascular ultrasound: A comparative study of healthy subjects

被引:9
|
作者
Maier, Ilko L. [1 ]
Hofer, Sabine [2 ]
Joseph, Arun A. [2 ,3 ]
Merboldt, K. Dietmar [2 ]
Tan, Zhengguo [2 ]
Schregel, Katharina [4 ,5 ]
Knauth, Michael [4 ]
Baehr, Mathias [1 ]
Psychogios, Marios-Nikos [4 ]
Liman, Jan [1 ]
Frahm, Jens [2 ,3 ]
机构
[1] Univ Med Ctr Gottingen, Dept Neurol, Robert Koch Str 40, D-37075 Gottingen, Germany
[2] Max Planck Inst Biophys Chem, Biomed NMR Forsch GmbH, Gottingen, Germany
[3] German Ctr Cardiovasc Res DZHK, Partner Site Gottingen, Gottingen, Germany
[4] Univ Med Ctr Gottingen, Dept Neuroradiol, Gottingen, Germany
[5] Harvard Med Sch, Brigham & Womens Hosp, Dept Radiol, Boston, MA USA
关键词
Carotid artery; Doppler sonography; Duplex sonography; Neurovascular ultrasound; Real-time flow MRI; Velocity profiles; QUANTIFICATION; RECONSTRUCTION; HEMODYNAMICS; BIFURCATION; POPULATION; RESOLUTION; VESSELS; MODEL;
D O I
10.1016/j.ejrad.2018.07.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The assessment of carotid artery flow by neurovascular ultrasound (nvUS) can be complemented by real-time phase-contrast (RT-PC) flow MRI which apart from quantitative flow parameters offers velocity distributions across the entire vessel lumen. Materials and methods: The feasibility and diagnostic potential of RT-PC flow MRI was evaluated in 20 healthy volunteers in comparison to conventional nvUS. RT-PC flow MRI at 40 ms temporal resolution and 0.8 mm in-plane resolution resulted in velocity maps with low phase noise and high spatiotemporal accuracy by exploiting respective advances of a recent nonlinear inverse model-based reconstruction. Peak-systolic velocities (PSV), end-diastolic velocities (EDV), flow volumes and comprehensive velocity profiles were determined in the common, internal and external carotid artery on both sides. Results: Flow characteristics such as pulsatility and individual abnormalities shown on nvUS could be reproduced and visualized in detail by RT-PC flow MRI. PSV to EDV differences revealed good agreement between both techniques, mean PSV and EDV were significantly lower and flow volumes were higher for MRI. Conclusion: Our findings suggest that RT-PC flow MRI adds to clinical diagnostics, e.g. by alterations of dynamic velocity distributions in patients with carotid stenosis. Lower PSV and EDV values than for nvUS mainly reflect the longer MRI acquisition time which attenuates short peak velocities, while higher flow volumes benefit from a proper assessment of the true vessel lumen.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 50 条
  • [41] Real-time phase-contrast MRI of cardiovascular blood flow using undersampled radial fast low-angle shot and nonlinear inverse reconstruction
    Joseph, Arun A.
    Merboldt, Klaus-Dietmar
    Voit, Dirk
    Zhang, Shuo
    Uecker, Martin
    Lotz, Joachim
    Frahm, Jens
    NMR IN BIOMEDICINE, 2012, 25 (07) : 917 - 924
  • [42] A Spatiotemporal exploration and 3D modeling of blood flow in healthy carotid artery bifurcation from two modalities: Ultrasound-Doppler and phase contrast MRI
    Debbich, Arij
    Ben Abdallah, Asma
    Maatouk, Mezri
    Hmida, Badii
    Sigovan, Monica
    Clarysse, Patrick
    Bedoui, Mohamed Hedi
    COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 118 (118)
  • [43] Measurement of Tongue Tip Velocity from Real-Time MRI and Phase-Contrast Cine-MRI in Consonant Production
    Isaieva, Karyna
    Laprie, Yves
    Odille, Freddy
    Douros, Ioannis K.
    Felblinger, Jacques
    Vuissoz, Pierre-Andre
    JOURNAL OF IMAGING, 2020, 6 (05)
  • [44] Measurement of tongue tip velocity from real-time MRI and phase-contrast cine-MRI in consonant production
    Isaieva K.
    Laprie Y.
    Odille F.
    Douros I.K.
    Felblinger J.
    Vuissoz P.-A.
    Journal of Imaging, 2020, 6 (31)
  • [45] 4-D Intracardiac Ultrasound Vector Flow Imaging-Feasibility and Comparison to Phase-Contrast MRI
    Wigen, Morten Smedsrud
    Fadnes, Solveig
    Rodriguez-Molares, Alfonso
    Bjastad, Tore
    Eriksen, Marius
    Stensaeth, Knut Haakon
    Stoylen, Asbjorn
    Lovstakken, Lasse
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (12) : 2619 - 2629
  • [46] Cerebral venous flow physiology and impact of cerebral venous thrombosis: a phase-contrast MRI study
    Sankari, S. Stoquart-El
    Lehmann, P.
    Villette, A.
    Deramond, H.
    Meyer, M. -E.
    Baledent, O.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 : S634 - S634
  • [47] CONTRAST-FREE BLOOD FLOW VELOCITY PROFILE MEASUREMENT WITH ULTRASOUND IN REAL-TIME
    Koutsouridis, G. G.
    Bijnens, N.
    van Geldermalsen, S.
    Brands, P. J.
    van de Vosse, F. N.
    Rutten, M. C. M.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2011, PTS A AND B, 2011, : 1121 - 1122
  • [48] Multiple blood flow measurements before and after carotid artery stenting via phase-contrast magnetic resonance imaging: An observational study
    Tanaka, Hisashi
    Watanabe, Yoshiyuki
    Nakamura, Hajime
    Takahashi, Hiroto
    Arisawa, Atsuko
    Fujiwara, Takuya
    Matsuo, Chisato
    Tomiyama, Noriyuki
    PLOS ONE, 2018, 13 (04):
  • [49] QUANTITATIVE MEASUREMENT OF PORTAL BLOOD-FLOW BY MAGNETIC-RESONANCE PHASE-CONTRAST - COMPARATIVE-STUDY OF FLOW PHANTOM AND DOPPLER ULTRASOUND IN-VIVO
    TSUNODA, M
    KIMOTO, S
    HAMAZAKI, K
    TAKEDA, Y
    HIRAKI, Y
    ACTA MEDICA OKAYAMA, 1994, 48 (05) : 283 - 288
  • [50] EVALUATION OF CEREBRAL BLOOD-FLOW WITH PHASE-CONTRAST CINE MR IN PATIENTS WITH ATHEROSCLEROTIC CAROTID-ARTERY DISEASE
    MARKS, MP
    LIDDELL, RP
    PELC, NJ
    ENZMANN, DR
    RADIOLOGY, 1992, 185 : 181 - 182