Carotid artery flow as determined by real-time phase-contrast flow MRI and neurovascular ultrasound: A comparative study of healthy subjects

被引:9
|
作者
Maier, Ilko L. [1 ]
Hofer, Sabine [2 ]
Joseph, Arun A. [2 ,3 ]
Merboldt, K. Dietmar [2 ]
Tan, Zhengguo [2 ]
Schregel, Katharina [4 ,5 ]
Knauth, Michael [4 ]
Baehr, Mathias [1 ]
Psychogios, Marios-Nikos [4 ]
Liman, Jan [1 ]
Frahm, Jens [2 ,3 ]
机构
[1] Univ Med Ctr Gottingen, Dept Neurol, Robert Koch Str 40, D-37075 Gottingen, Germany
[2] Max Planck Inst Biophys Chem, Biomed NMR Forsch GmbH, Gottingen, Germany
[3] German Ctr Cardiovasc Res DZHK, Partner Site Gottingen, Gottingen, Germany
[4] Univ Med Ctr Gottingen, Dept Neuroradiol, Gottingen, Germany
[5] Harvard Med Sch, Brigham & Womens Hosp, Dept Radiol, Boston, MA USA
关键词
Carotid artery; Doppler sonography; Duplex sonography; Neurovascular ultrasound; Real-time flow MRI; Velocity profiles; QUANTIFICATION; RECONSTRUCTION; HEMODYNAMICS; BIFURCATION; POPULATION; RESOLUTION; VESSELS; MODEL;
D O I
10.1016/j.ejrad.2018.07.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The assessment of carotid artery flow by neurovascular ultrasound (nvUS) can be complemented by real-time phase-contrast (RT-PC) flow MRI which apart from quantitative flow parameters offers velocity distributions across the entire vessel lumen. Materials and methods: The feasibility and diagnostic potential of RT-PC flow MRI was evaluated in 20 healthy volunteers in comparison to conventional nvUS. RT-PC flow MRI at 40 ms temporal resolution and 0.8 mm in-plane resolution resulted in velocity maps with low phase noise and high spatiotemporal accuracy by exploiting respective advances of a recent nonlinear inverse model-based reconstruction. Peak-systolic velocities (PSV), end-diastolic velocities (EDV), flow volumes and comprehensive velocity profiles were determined in the common, internal and external carotid artery on both sides. Results: Flow characteristics such as pulsatility and individual abnormalities shown on nvUS could be reproduced and visualized in detail by RT-PC flow MRI. PSV to EDV differences revealed good agreement between both techniques, mean PSV and EDV were significantly lower and flow volumes were higher for MRI. Conclusion: Our findings suggest that RT-PC flow MRI adds to clinical diagnostics, e.g. by alterations of dynamic velocity distributions in patients with carotid stenosis. Lower PSV and EDV values than for nvUS mainly reflect the longer MRI acquisition time which attenuates short peak velocities, while higher flow volumes benefit from a proper assessment of the true vessel lumen.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 50 条
  • [31] Quantification of blood flow velocity of the internal carotid artery: a comparison between phase- Contrast MRI and Doppler Ultrasound
    Safavi, Tahere Sadat
    Fatouraee, Nasser
    Soleimani, Effat
    [J]. 2017 24TH NATIONAL AND 2ND INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2017, : 95 - 98
  • [32] Improved cardiovascular flow quantification with time-resolved volumetric phase-contrast MRI
    Albert Hsiao
    Marcus T. Alley
    Payam Massaband
    Robert J. Herfkens
    Frandics P. Chan
    Shreyas S. Vasanawala
    [J]. Pediatric Radiology, 2011, 41 : 711 - 720
  • [33] Real-time phase-contrast flow cardiovascular magnetic resonance with low-rank modeling and parallel imaging
    Sun, Aiqi
    Zhao, Bo
    Li, Yunduo
    He, Qiong
    Li, Rui
    Yuan, Chun
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [34] Real-time phase-contrast flow cardiovascular magnetic resonance with low-rank modeling and parallel imaging
    Aiqi Sun
    Bo Zhao
    Yunduo Li
    Qiong He
    Rui Li
    Chun Yuan
    [J]. Journal of Cardiovascular Magnetic Resonance, 19
  • [35] Real-time laser speckle contrast imaging for intraoperative neurovascular blood flow assessment: animal experimental study
    Konovalov, Anton
    Grebenev, Fyodor
    Stavtsev, Dmitry
    Kozlov, Igor
    Gadjiagaev, Vadim
    Piavchenko, Gennadii
    Telyshev, Dmitry
    Gerasimenko, Alexander Yu.
    Meglinski, Igor
    Zalogin, Savely
    Artemyev, Anton
    Golodnev, Grigorii
    Shumeiko, Tatiana
    Eliava, Shalva
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01)
  • [36] Real-time laser speckle contrast imaging for intraoperative neurovascular blood flow assessment: animal experimental study
    Anton Konovalov
    Fyodor Grebenev
    Dmitry Stavtsev
    Igor Kozlov
    Vadim Gadjiagaev
    Gennadii Piavchenko
    Dmitry Telyshev
    Alexander Yu. Gerasimenko
    Igor Meglinski
    Savely Zalogin
    Anton Artemyev
    Grigorii Golodnev
    Tatiana Shumeiko
    Shalva Eliava
    [J]. Scientific Reports, 14
  • [37] Common Carotid Artery Volume Flow: A Comparison Study between Ultrasound Vector Flow Imaging and Phase Contrast Magnetic Resonance Imaging
    Brandt, Andreas Hjelm
    Olesen, Jacob Bjerring
    Moshavegh, Ramin
    Jensen, Jorgen Arendt
    Nielsen, Michael Bachmann
    Hansen, Kristoffer Lindskov
    [J]. NEUROLOGY INTERNATIONAL, 2021, 13 (03) : 269 - 278
  • [38] Use of real-time phase-contrast MRI to quantify the effect of spontaneous breathing on the cerebral arteries
    Liu, Pan
    Fall, Sidy
    Baledent, Olivier
    [J]. NEUROIMAGE, 2022, 258
  • [39] Blood flow quantification in adults by phase-contrast MRI combined with SENSE -: a validation study
    Beerbaum, P
    Körperich, H
    Gieseke, J
    Barth, P
    Peuster, M
    Meyer, H
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (02) : 361 - 369
  • [40] Real-time phase-contrast MRI of cardiovascular blood flow using undersampled radial fast low-angle shot and nonlinear inverse reconstruction
    Joseph, Arun A.
    Merboldt, Klaus-Dietmar
    Voit, Dirk
    Zhang, Shuo
    Uecker, Martin
    Lotz, Joachim
    Frahm, Jens
    [J]. NMR IN BIOMEDICINE, 2012, 25 (07) : 917 - 924