Carotid artery flow as determined by real-time phase-contrast flow MRI and neurovascular ultrasound: A comparative study of healthy subjects

被引:9
|
作者
Maier, Ilko L. [1 ]
Hofer, Sabine [2 ]
Joseph, Arun A. [2 ,3 ]
Merboldt, K. Dietmar [2 ]
Tan, Zhengguo [2 ]
Schregel, Katharina [4 ,5 ]
Knauth, Michael [4 ]
Baehr, Mathias [1 ]
Psychogios, Marios-Nikos [4 ]
Liman, Jan [1 ]
Frahm, Jens [2 ,3 ]
机构
[1] Univ Med Ctr Gottingen, Dept Neurol, Robert Koch Str 40, D-37075 Gottingen, Germany
[2] Max Planck Inst Biophys Chem, Biomed NMR Forsch GmbH, Gottingen, Germany
[3] German Ctr Cardiovasc Res DZHK, Partner Site Gottingen, Gottingen, Germany
[4] Univ Med Ctr Gottingen, Dept Neuroradiol, Gottingen, Germany
[5] Harvard Med Sch, Brigham & Womens Hosp, Dept Radiol, Boston, MA USA
关键词
Carotid artery; Doppler sonography; Duplex sonography; Neurovascular ultrasound; Real-time flow MRI; Velocity profiles; QUANTIFICATION; RECONSTRUCTION; HEMODYNAMICS; BIFURCATION; POPULATION; RESOLUTION; VESSELS; MODEL;
D O I
10.1016/j.ejrad.2018.07.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The assessment of carotid artery flow by neurovascular ultrasound (nvUS) can be complemented by real-time phase-contrast (RT-PC) flow MRI which apart from quantitative flow parameters offers velocity distributions across the entire vessel lumen. Materials and methods: The feasibility and diagnostic potential of RT-PC flow MRI was evaluated in 20 healthy volunteers in comparison to conventional nvUS. RT-PC flow MRI at 40 ms temporal resolution and 0.8 mm in-plane resolution resulted in velocity maps with low phase noise and high spatiotemporal accuracy by exploiting respective advances of a recent nonlinear inverse model-based reconstruction. Peak-systolic velocities (PSV), end-diastolic velocities (EDV), flow volumes and comprehensive velocity profiles were determined in the common, internal and external carotid artery on both sides. Results: Flow characteristics such as pulsatility and individual abnormalities shown on nvUS could be reproduced and visualized in detail by RT-PC flow MRI. PSV to EDV differences revealed good agreement between both techniques, mean PSV and EDV were significantly lower and flow volumes were higher for MRI. Conclusion: Our findings suggest that RT-PC flow MRI adds to clinical diagnostics, e.g. by alterations of dynamic velocity distributions in patients with carotid stenosis. Lower PSV and EDV values than for nvUS mainly reflect the longer MRI acquisition time which attenuates short peak velocities, while higher flow volumes benefit from a proper assessment of the true vessel lumen.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 50 条
  • [21] Real-time phase-contrast flow MRI of haemodynamic changes in the ascending aorta and superior vena cava during Mueller manoeuvre
    Fasshauer, M.
    Joseph, A. A.
    Kowallick, J. T.
    Unterberg-Buchwald, C.
    Merboldt, K. D.
    Voit, D.
    Steinmetz, M.
    Staab, W.
    Schaetz, S.
    Zhang, S.
    Frahm, J.
    Lotz, J.
    Sohns, J. M.
    [J]. CLINICAL RADIOLOGY, 2014, 69 (10) : 1066 - 1071
  • [22] Optimized analysis of blood flow and wall shear stress in the common carotid artery of rat model by phase-contrast MRI
    Peng, Shin-Lei
    Shih, Cheng-Ting
    Huang, Chiun-Wei
    Chiu, Shao-Chieh
    Shen, Wu-Chung
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [23] Optimized analysis of blood flow and wall shear stress in the common carotid artery of rat model by phase-contrast MRI
    Shin-Lei Peng
    Cheng-Ting Shih
    Chiun-Wei Huang
    Shao-Chieh Chiu
    Wu-Chung Shen
    [J]. Scientific Reports, 7
  • [24] Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI
    Park, JB
    Santos, JM
    Hargreaves, BA
    Nayak, KS
    Sommer, G
    Hu, BS
    Nishimura, DG
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (05) : 590 - 595
  • [25] Comparison of Cartesian, UTE radial, and Spiral Phase-Contrast MRI in Measurement of Blood Flow in Extracranial Carotid Arteries: Normal Subjects
    Negahdar, M. J.
    Kadbi, M. O.
    Tavakoli, Vahid
    Heidenreich, Jens
    Amini, Amir A.
    [J]. MEDICAL IMAGING 2013: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2013, 8672
  • [26] Perturbed spiral real-time phase-contrast MR with compressive sensing reconstruction for assessment of flow in children
    Kowalik, Grzegorz Tomasz
    Knight, Daniel
    Steeden, Jennifer Anne
    Muthurangu, Vivek
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (06) : 2077 - 2091
  • [27] Simultaneous Phase-Contrast MRI and PET for Noninvasive Quantification of Cerebral Blood Flow and Reactivity in Healthy Subjects and Patients With Cerebrovascular Disease
    Ishii, Yosuke
    Thamm, Thoralf
    Guo, Jia
    Khalighi, Mohammad Mehdi
    Wardak, Mirwais
    Holley, Dawn
    Gandhi, Harsh
    Park, Jun Hyung
    Shen, Bin
    Steinberg, Gary K.
    Chin, Frederick T.
    Zaharchuk, Greg
    Fan, Audrey Peiwen
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (01) : 183 - 194
  • [28] Velocity vector reconstruction for real-time phase-contrast MRI with radial Maxwell correction
    Kollmeier, Jost M.
    Kalentev, Oleksandr
    Klosowski, Jakob
    Voit, Dirk
    Frahm, Jens
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1863 - 1875
  • [29] Assessment of cerebral blood flow in neonates and infants: A phase-contrast MRI study
    Liu, Peiying
    Qi, Ying
    Lin, Zixuan
    Guo, Qiyong
    Wang, Xiaoming
    Lu, Hanzhang
    [J]. NEUROIMAGE, 2019, 185 : 926 - 933
  • [30] Improved cardiovascular flow quantification with time-resolved volumetric phase-contrast MRI
    Hsiao, Albert
    Alley, Marcus T.
    Massaband, Payam
    Herfkens, Robert J.
    Chan, Frandics P.
    Vasanawala, Shreyas S.
    [J]. PEDIATRIC RADIOLOGY, 2011, 41 (06) : 711 - 720