Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI

被引:16
|
作者
Park, JB
Santos, JM
Hargreaves, BA
Nayak, KS
Sommer, G
Hu, BS
Nishimura, DG
机构
[1] Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
[2] Univ So Calif, Dept Elect Engn, Los Angeles, CA 90089 USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Palo Alto Med Fdn, Palo Alto, CA USA
关键词
renal; vascular; flow; fast imaging; phase-contrast; spiral;
D O I
10.1002/jmri.20325
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To verify the potential of ungated spiral phase-contrast (USPC), which has been shown to provide accurate and reproducible time-averaged measurements of pulsatile flow, for rapid measurement of renal artery blood flow (RABF) in vivo. Materials and Methods: The RABF rates of 11 normal human subjects and one patient with renal failure were measured with USPC within six seconds. Results: Rapid USPC scans produced reproducible RABF measurements (SD <= 9%) that agreed with the normal RABF rates known from the literature. The RABF rates of the patient with renal failure were substantially less (< 50-65%) than the normal RABF rates. Conclusion: The results demonstrate that it is now possible to obtain rapid and consistent RABF measurements within six seconds with USPC.
引用
收藏
页码:590 / 595
页数:6
相关论文
共 50 条
  • [1] Rapid measurement of time-averaged blood flow using ungated spiral phase-contrast
    Park, JB
    Olcott, EW
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) : 322 - 328
  • [2] Rapid Flow Quantification in Iliac Arteries with Spiral Phase-Contrast MRI
    Negahdar, M. J.
    Kadbi, Mo
    Kotys, Melanie
    Alshaher, Motaz
    Fischer, Stefan
    Amini, Amir A.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2804 - 2808
  • [3] Rapid cardiac-output measurement with ungated spiral phase contrast
    Park, Jong B.
    Hu, Bob S.
    Conolly, Steven M.
    Nayak, Krishna S.
    Nishimura, Dwight G.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (02) : 432 - 438
  • [4] COMPARISON OF CEREBRAL-ARTERY BLOOD-FLOW MEASUREMENTS WITH GATED CINE AND UNGATED PHASE-CONTRAST TECHNIQUES
    ENZMANN, DR
    MARKS, MP
    PELC, NJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05): : 705 - 712
  • [5] Cine Phase-Contrast Magnetic Resonance Imaging for the Measurement of Renal Blood Flow
    Prowle, John R.
    Molan, Maurice P.
    Hornsey, Emma
    Bellomo, Rinaldo
    CARDIORENAL SYNDROMES IN CRITICAL CARE, 2010, 165 : 329 - 336
  • [6] Comparison of Cartesian, UTE radial, and Spiral Phase-Contrast MRI in Measurement of Blood Flow in Extracranial Carotid Arteries: Normal Subjects
    Negahdar, M. J.
    Kadbi, M. O.
    Tavakoli, Vahid
    Heidenreich, Jens
    Amini, Amir A.
    MEDICAL IMAGING 2013: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2013, 8672
  • [7] PHASE-CONTRAST MRI ASSESSMENT OF PEDAL BLOOD-FLOW
    DEBATIN, JF
    DALMAN, R
    HERFKENS, RJ
    HARRIS, EJ
    PELC, NJ
    EUROPEAN RADIOLOGY, 1995, 5 (01) : 36 - 42
  • [8] Noninvasive analysis of renal artery blood flow dynamics with MR cine phase-contrast flow measurements
    Schoenberg, SO
    Just, A
    Bock, M
    Knopp, MV
    Persson, PB
    Kirchheim, HR
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 272 (05): : H2477 - H2484
  • [9] Effect of age on cerebral blood flow: Measurement with ungated two-dimensional phase-contrast MR angiography in 250 adults
    Buijs, PC
    Krabbe-Hartkamp, MJ
    Bakker, CJG
    de Lange, EE
    Ramos, LMP
    Breteler, MMB
    Mali, WPTM
    RADIOLOGY, 1998, 209 (03) : 667 - 674
  • [10] Assessment of Flow and Hemodynamics in the Carotid Artery Using a Reduced TE 4D Flow Spiral Phase-Contrast MRI
    Kadbi, Mo
    Negandar, Mj
    Traughber, Melanie
    Martin, Peter
    Amini, Amir A.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 1100 - 1103