Biomechanical Evaluation of Bioabsorbable Versus Metallic Screws for Posterior Cruciate Ligament Inlay Graft Fixation A Comparative Study

被引:16
|
作者
Gupta, Aman [2 ]
Lattermann, Christian [3 ]
Busam, Matthew [4 ]
Riff, Andrew [5 ]
Bach, Bernard R., Jr. [1 ]
Wang, Vincent M.
机构
[1] Rush Univ, Div Sports Med, Med Ctr, Dept Orthopaed Surg, Chicago, IL 60612 USA
[2] Univ Illinois, Dept Bioengn, Chicago, IL USA
[3] Univ Kentucky, Coll Med, Dept Orthopaed Surg, Lexington, KY USA
[4] Cincinnati Sports Med Res & Educ Fdn, Cincinnati, OH USA
[5] Georgetown Med Sch, Washington, DC USA
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2009年 / 37卷 / 04期
关键词
knee; posterior cruciate ligament; inlay; reconstruction; tendon graft; TENDON-BONE GRAFT; TIBIAL INLAY; INTERFERENCE SCREWS; TRANSTIBIAL TECHNIQUES; ANKLE FRACTURES; SINGLE-BUNDLE; FOLLOW-UP; RECONSTRUCTION; STRENGTH; FAILURE;
D O I
10.1177/0363546508328106
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although a tibial inlay technique for posterior cruciate ligament reconstruction is advantageous, metallic screw fixation of the bone block is required. This may pose problems for future surgery (eg, osteotomies, total knee replacement). Hypothesis: There is no significant difference in the biomechanical integrity of bone block fixation using stainless steel versus bioabsorbable screw fixation of the tibial inlay graft in posterior cruciate ligament reconstruction. Study Design: Controlled laboratory study. Methods: Fourteen human cadaveric knees were randomized to receive either stainless steel or bioabsorbable screw fixation of a bone-patellar tendon-bone graft. Cyclic tensile testing of each construct was performed, followed by a load-to-failure test. Digital video digitization was used to optically determine tendon graft deformation. Results: Cyclic creep deformation showed no significant difference between the 2 groups (P = .8). The failure load S stainless steel, 461 +/- 231 N; bioabsorbable, 638 +/- 492 N; P = .7) and linear stiffness S stainless steel, 116 +/- 22 N/mm, bioabsorbable, 106 +/- 44 N/mm; P = .6) also showed no significant difference between the 2 groups. Optically measured graft deformation was not significant for distal (P = .7) and midsubstance (P = .8) regions, while proximal deformation was significantly higher for bioabsorbable fixation (P = .02). All samples failed at the tibial insertion site with the tibial bone block fracturing at the screws. Conclusion: Bioabsorbable screw fixation using a tibial inlay technique does not compromise the strength and stiffness characteristics afforded by metallic fixation. From a biomechanical perspective, bioabsorbable screws are a viable alternative to metal in the context of tibial inlay reconstruction. Clinical Relevance: Use of bioabsorbable fixation can potentially eliminate future hardware problems after posterior cruciate ligament reconstruction using a tibial inlay technique.
引用
收藏
页码:748 / 753
页数:6
相关论文
共 50 条
  • [1] Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction
    Debieux, Pedro
    Franciozi, Carlos E. S.
    Lenza, Mario
    Tamaoki, Marcel Jun
    Magnussen, Robert A.
    Faloppa, Flavio
    Belloti, Joao Carlos
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (07):
  • [2] Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction
    McGuire, DA
    Barber, FA
    Elrod, BF
    Paulos, LE
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1999, 15 (05): : 463 - 473
  • [3] Does thread shape affect the fixation strength of the bioabsorbable interference screws for anterior cruciate ligament reconstructions? A biomechanical study
    Garces, Gerardo L.
    Martel, Oscar
    Yanez, Alejandro
    Cuadrado, Alberto
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [4] Does thread shape affect the fixation strength of the bioabsorbable interference screws for anterior cruciate ligament reconstructions? A biomechanical study
    Gerardo L. Garcés
    Oscar Martel
    Alejandro Yánez
    Alberto Cuadrado
    BMC Musculoskeletal Disorders, 20
  • [5] Metallic or bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction?
    Papalia, Rocco
    Vasta, Sebastiano
    D'Adamio, Stefano
    Giacalone, Antonino
    Maffulli, Nicola
    Denaro, Vincenzo
    BRITISH MEDICAL BULLETIN, 2014, 109 (01) : 19 - 29
  • [6] Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws
    Tecklenburg, Katja
    Burkart, Peter
    Hoser, Christian
    Rieger, Michael
    Fink, Christian
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (09): : 993 - 999
  • [7] Initial fixation strength of bioabsorbable and titanium interference screws in anterior cruciate ligament reconstruction -: Biomechanical evaluation by single cycle and cyclic loading
    Kousa, P
    Järvinen, TLN
    Kannus, P
    Järvinen, M
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2001, 29 (04): : 420 - 425
  • [8] Biomechanical comparison of tibial inlay versus transtibial techniques for posterior cruciate ligament reconstruction - Analysis of knee kinematics and graft in situ forces
    Margheritini, F
    Mauro, CS
    Rihn, JA
    Stabile, KJ
    Woo, SLY
    Harner, CD
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (03): : 587 - 593
  • [9] Biomechanical evaluation of different anterior cruciate ligament fixation techniques for hamstring graft
    Monaco, E.
    Labianca, L.
    Speranza, A.
    Agro, A. M.
    Camillieri, G.
    D'Arrigo, C.
    Ferretti, A.
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2010, 15 (01) : 125 - 131
  • [10] Biomechanical comparison of tibial inlay and tibial tunnel techniques for reconstruction of the posterior cruciate ligament - Analysis of graft forces
    Oakes, DA
    Markolf, KL
    McWilliams, J
    Young, CR
    McAllister, DR
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (06): : 938 - 944