Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction

被引:36
|
作者
Debieux, Pedro [1 ,2 ]
Franciozi, Carlos E. S. [1 ]
Lenza, Mario [2 ]
Tamaoki, Marcel Jun [1 ]
Magnussen, Robert A. [3 ]
Faloppa, Flavio [1 ]
Belloti, Joao Carlos [1 ]
机构
[1] Univ Fed Sao Paulo, Dept Orthopaed & Traumatol, Rua Borges Lagoa 783 5th Floor, BR-04038032 Sao Paulo, Brazil
[2] Hosp Israelita Albert Einstein, Orthopaed & Trauma Dept, Sao Paulo, Brazil
[3] Ohio State Univ, Med Ctr, Orthopaed Surg, Columbus, OH 43210 USA
关键词
RANDOMIZED CONTROLLED-TRIAL; TENDON GRAFT; HAMSTRING AUTOGRAFT; ABSORBABLE INTERFERENCE; INSERTION TORQUE; TITANIUM SCREWS; TIBIAL FIXATION; DOUBLE-BUNDLE; STRENGTH; KNEE;
D O I
10.1002/14651858.CD009772.pub2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Anterior cruciate ligament (ACL) tears are frequently treated with surgical reconstruction with grafts, frequently patella tendon or hamstrings. Interference screws are often used to secure the graft in bone tunnels in the femur and tibia. This review examines whether bioabsorbable interference screws give better results than metal interference screws when used for graft fixation in ACL reconstruction. Objectives To assess the effects (benefits and harms) of bioabsorbable versus metallic interference screws for graft fixation in ACL reconstruction. Search methods We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, CENTRAL (the Cochrane Library), MEDLINE, Embase, LILACS, trial registers and reference lists of articles. Date of search: January 2016. Selection criteria We included randomised controlled trials and quasi-randomised trials comparing bioabsorbable with metallic interferences screws in ACL reconstruction. The main outcomes sought were subjective-rated knee function, failure of treatment, and activity level. Data collection and analysis At least two review authors selected eligible trials, independently assessed risk of bias, and cross-checked data. Data were pooled whenever relevant and possible. Requests for further information were sent to the original study authors. Main results We included 12 trials (11 randomised and one quasi-randomised) involving a total of 944 participants, and reporting follow-up results for 774. Participants in the 12 trials underwent ACL reconstruction with either hamstring tendon grafts (five trials) or patellar tendon grafts (seven trials). Trials participants were randomly allocated to bioabsorbable or metallic interference screws for graft fixation in both femur and tibia (seven trials); femur only (three trials); tibia only (one trial); location was not reported in the remaining trial. A variety of materials was used for the bioabsorbable screws, Poly-L-lactic acid (PLLA) being the most common. The metallic screws, where reported, were titanium. All trials were at high risk of bias, which invariably included performance bias. Seven trials were at high risk of attrition bias and eight at high risk of reporting bias. The quasi-randomised trial was assessed as being at high risk for selection bias. Based on these study limitations and insufficiency of the available data, we judged the quality of evidence for all outcomes was very low. The majority of the available data for patient-reported knee function was presented as Lysholm scores (0 to 100; higher scores = better function). There was very low quality but consistent evidence of no clinically important differences between the two groups in Lysholm scores at 12 months follow-up (mean difference (MD) -0.08, 95% confidence interval (CI) -1.48 to 1.32; three trials, 168 participants); 24 months (MD 0.35, 95% CI -1.27 to 1.98; three trials, 113 participants) or five or more years follow-up (MD 1.23, 95% CI -2.00 to 4.47; two trials, 71 participants). This lack of between-group differences was also reported for Lysholm scores in several trials that did not provide sufficient data for pooling as well as for other self-reported knee function scores reported in several trials. Treatment failure was represented by the summed data for implant breakage during surgery and major postoperative complications (implant failure, graft rupture, symptomatic foreign body reactions, effusion and treated arthrofibrosis and related conditions) that were usually described in the trial reports as requiring further substantive treatment. There is very low-quality evidence of greater treatment failure in the bioabsorbable screw group (60/451 versus 29/434; risk ratio (RR) 1.94 favouring metallic screw fixation, 95% CI 1.29 to 2.93; 885 participants, 11 studies). In a population with an assumed risk (based on the median control group risk) of 56 participants per 1000 having treatment failure after metallic screw fixation, this equates to 53 more (95% CI 17 to 108 more) per 1000 participants having treatment failure after bioabsorbable screw fixation. All 16 intraoperative complications in the bioabsorbable screw group were implant breakages upon screw insertion. Treatment failure defined as postoperative complications only still favoured the metallic screw group but the 95% CI also included the potential for a greater risk of treatment failure after metallic screw fixation: 44/451 versus 29/434; RR 1.44, 95% CI 0.93 to 2.23. Based on the assumed risk of 56 participants per 1000 having postoperative treatment failure after metallic screw fixation, this equates to 25 more (95% CI 4 fewer and 69 more) per 1000 participants having this outcome after bioabsorbable screw fixation. There was very low-quality evidence of very similar activity levels in the two groups at 12 and 24 months follow-up measured via the Tegner score (0 to 10; higher scores = greater activity): 12 months (MD 0.08, 95% CI -0.39 to 0.55; 122 participants, two studies); 24 months (MD 0.01, 95% CI -0.54 to 0.57; 72 participants, two studies). Authors' conclusions There is very low-quality evidence of no difference in self-reported knee function and levels of activity between bioabsorbable and metallic interference screws for graft fixation in ACL reconstruction. There is very low-quality evidence that bioabsorbable screws may be associated with more overall treatment failures, including implant breakage during surgery. Further research does not appear to be a priority, but if undertaken, should also examine costs.
引用
收藏
页数:86
相关论文
共 50 条
  • [1] Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction
    McGuire, DA
    Barber, FA
    Elrod, BF
    Paulos, LE
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1999, 15 (05): : 463 - 473
  • [2] Metallic or bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction?
    Papalia, Rocco
    Vasta, Sebastiano
    D'Adamio, Stefano
    Giacalone, Antonino
    Maffulli, Nicola
    Denaro, Vincenzo
    BRITISH MEDICAL BULLETIN, 2014, 109 (01) : 19 - 29
  • [3] Comparison of bioabsorbable interference screws and posts for distal fixation in anterior cruciate ligament reconstruction
    Krzysztof Gawęda
    Jacek Walawski
    Robert Węgłowski
    Wojciech Krzyżanowski
    International Orthopaedics, 2009, 33 : 123 - 127
  • [4] Comparison of bioabsorbable interference screws and posts for distal fixation in anterior cruciate ligament reconstruction
    Gaweda, Krzysztof
    Walawski, Jacek
    Weglowski, Robert
    Krzyzanowski, Wojciech
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (01) : 123 - 127
  • [5] The Use of Bioabsorbable Interference Screws in Reconstruction of the Anterior Cruciate Ligament of the Knee
    Radulescu, Radu
    Badila, Adrian
    Manolescu, Robert
    Japie, Ioan
    Bolocan, Alexandra
    MATERIALE PLASTICE, 2014, 51 (01) : 101 - 103
  • [6] Bioabsorbable Versus Metallic Interference Screws in Anterior Cruciate Ligament Reconstruction: A Systematic Review of Overlapping Meta-analyses
    Mascarenhas, Randy
    Saltzman, Bryan M.
    Sayegh, Eli T.
    Verma, Nikhil N.
    Cole, Brian J.
    Bush-Joseph, Charles
    Bach, Bernard R., Jr.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2015, 31 (03): : 561 - 568
  • [7] Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws
    Tecklenburg, Katja
    Burkart, Peter
    Hoser, Christian
    Rieger, Michael
    Fink, Christian
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (09): : 993 - 999
  • [8] Comparison of resorption and remodeling of bioabsorbable interference screws in anterior cruciate ligament reconstruction
    Panagiotis G. Ntagiopoulos
    Guillaume Demey
    Thierry Tavernier
    David Dejour
    International Orthopaedics, 2015, 39 : 697 - 706
  • [9] Comparison of resorption and remodeling of bioabsorbable interference screws in anterior cruciate ligament reconstruction
    Ntagiopoulos, Panagiotis G.
    Demey, Guillaume
    Tavernier, Thierry
    Dejour, David
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (04) : 697 - 706
  • [10] Biomechanical Evaluation of Bioabsorbable Versus Metallic Screws for Posterior Cruciate Ligament Inlay Graft Fixation A Comparative Study
    Gupta, Aman
    Lattermann, Christian
    Busam, Matthew
    Riff, Andrew
    Bach, Bernard R., Jr.
    Wang, Vincent M.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (04): : 748 - 753