Biomechanical Evaluation of Bioabsorbable Versus Metallic Screws for Posterior Cruciate Ligament Inlay Graft Fixation A Comparative Study

被引:16
|
作者
Gupta, Aman [2 ]
Lattermann, Christian [3 ]
Busam, Matthew [4 ]
Riff, Andrew [5 ]
Bach, Bernard R., Jr. [1 ]
Wang, Vincent M.
机构
[1] Rush Univ, Div Sports Med, Med Ctr, Dept Orthopaed Surg, Chicago, IL 60612 USA
[2] Univ Illinois, Dept Bioengn, Chicago, IL USA
[3] Univ Kentucky, Coll Med, Dept Orthopaed Surg, Lexington, KY USA
[4] Cincinnati Sports Med Res & Educ Fdn, Cincinnati, OH USA
[5] Georgetown Med Sch, Washington, DC USA
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2009年 / 37卷 / 04期
关键词
knee; posterior cruciate ligament; inlay; reconstruction; tendon graft; TENDON-BONE GRAFT; TIBIAL INLAY; INTERFERENCE SCREWS; TRANSTIBIAL TECHNIQUES; ANKLE FRACTURES; SINGLE-BUNDLE; FOLLOW-UP; RECONSTRUCTION; STRENGTH; FAILURE;
D O I
10.1177/0363546508328106
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although a tibial inlay technique for posterior cruciate ligament reconstruction is advantageous, metallic screw fixation of the bone block is required. This may pose problems for future surgery (eg, osteotomies, total knee replacement). Hypothesis: There is no significant difference in the biomechanical integrity of bone block fixation using stainless steel versus bioabsorbable screw fixation of the tibial inlay graft in posterior cruciate ligament reconstruction. Study Design: Controlled laboratory study. Methods: Fourteen human cadaveric knees were randomized to receive either stainless steel or bioabsorbable screw fixation of a bone-patellar tendon-bone graft. Cyclic tensile testing of each construct was performed, followed by a load-to-failure test. Digital video digitization was used to optically determine tendon graft deformation. Results: Cyclic creep deformation showed no significant difference between the 2 groups (P = .8). The failure load S stainless steel, 461 +/- 231 N; bioabsorbable, 638 +/- 492 N; P = .7) and linear stiffness S stainless steel, 116 +/- 22 N/mm, bioabsorbable, 106 +/- 44 N/mm; P = .6) also showed no significant difference between the 2 groups. Optically measured graft deformation was not significant for distal (P = .7) and midsubstance (P = .8) regions, while proximal deformation was significantly higher for bioabsorbable fixation (P = .02). All samples failed at the tibial insertion site with the tibial bone block fracturing at the screws. Conclusion: Bioabsorbable screw fixation using a tibial inlay technique does not compromise the strength and stiffness characteristics afforded by metallic fixation. From a biomechanical perspective, bioabsorbable screws are a viable alternative to metal in the context of tibial inlay reconstruction. Clinical Relevance: Use of bioabsorbable fixation can potentially eliminate future hardware problems after posterior cruciate ligament reconstruction using a tibial inlay technique.
引用
收藏
页码:748 / 753
页数:6
相关论文
共 50 条
  • [41] BIOMECHANICAL PERFORMANCE OF METALLIC AND BIOABSORBABLE INTERFERENCE SCREW FOR TIBIAL GRAFT FIXATION IN ACL RECONSTRUCTION
    Ocampo More, Ari Digiacomo
    Almeida Pizzolatti, Andre Luiz
    Fancello, Eduardo
    de Mello Roesler, Carlos Rodrigo
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [42] Tibial Inlay Technique Using Hamstring Graft for Posterior Cruciate Ligament Reconstruction and Remnant Revision
    Laupattarakasem, Wiroon
    Boonard, Manusak
    Laupattarakasem, Pat
    Kosuwon, Weerachai
    ARTHROSCOPY TECHNIQUES, 2013, 2 (01): : E1 - E7
  • [43] The effect of femoral tunnel position on graft forces during inlay posterior cruciate ligament reconstruction
    Oakes, DA
    Markolf, KL
    McWilliams, J
    Young, CR
    McAllister, DR
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (05): : 667 - 672
  • [44] Comparative study of fixation mode in total knee arthroplasty with preservation of the posterior cruciate ligament
    Gicquel, P
    Kempf, JF
    Gastaud, F
    Schlemmer, B
    Bonnomet, F
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2000, 86 (03): : 240 - 249
  • [45] Bioabsorbable Versus Metallic Interference Screw Fixation in Anterior Cruciate Ligament Reconstruction: A Meta-Analysis of Randomized Controlled Trials
    Shen, Chao
    Jiang, Sheng-Dan
    Jiang, Lei-Sheng
    Dai, Li-Yang
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (05): : 705 - 713
  • [46] THE BIOMECHANICAL STUDY OF DIFFERENT POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION TECHNIQUES
    Guo, Na
    Qi, Yansong
    Yang, Biao
    Han, Zhonghao
    Hu, Lei
    Xu, Yongsheng
    Wang, Tianmiao
    Yu, Jiakuo
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2018, 18 (08)
  • [47] Femoral fixation of hamstring grafts in posterior cruciate ligament reconstruction: Biomechanical evaluation of different fixation techniques - Is there an acutle angle effect?
    Niedzwietzki, Patricia
    Zantop, Thore
    Weimann, Andre
    Herbort, Mirco
    Raschke, Michael J.
    Petersen, Wolf
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (05): : 780 - 786
  • [48] A biomechanical evaluation of transcondylar femoral fixation of anterior cruciate ligament grafts
    Camillieri, G
    McFarland, EG
    Jasper, LE
    Belkoff, SM
    Kim, TK
    Rauh, PB
    Mariani, PP
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (04): : 950 - 955
  • [49] Anterior cruciate ligament graft fixation first in anterior and posterior cruciate ligament reconstruction best restores knee kinematics
    Zheng, Libin
    Sabzevari, Soheil
    Marshall, Brandon
    Zhu, Junjun
    Linde, Monica A.
    Smolinski, Patrick
    Fu, Freddie H.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (04) : 1237 - 1244
  • [50] Onlay Reconstruction of the Posterior Cruciate Ligament: Biomechanical Comparison of Unicortical and Bicortical Tibial Fixation
    de Albuquerque, Joao Bourbon, II
    Pfeiffer, Ferris
    Stannard, James P.
    Cook, James L.
    Kfuri, Mauricio
    JOURNAL OF KNEE SURGERY, 2019, 32 (10) : 972 - 978