Accuracy of dental digitizers

被引:0
|
作者
Vlaar, Simon T.
van der Zel, Jef M.
机构
[1] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Computerized Dent, NL-1066 EA Amsterdam, Netherlands
[2] Free Univ Amsterdam, NL-1066 EA Amsterdam, Netherlands
关键词
dental CAD/CAM; surface digitization device; laser-triangulation scanning; dental imaging; scanning accuracy;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The need for proper validation and verification methodology for CAD/CAM systems is imminent. CAD/CAM systems consisting of an optical impression system, design software and a fabrication machine have to perform to a certain level, whereby manufacturers need to prove the effectiveness of the system as a whole. However, especially when dental surface digitization devices are used as open, stand-alone applications in dental outsourcing, a reliable standard test for comparison is necessary. Purpose: This study evaluates a proposed test method to be used to quantify "digitizing quality" with respect to accuracy and reproducibility of two dental surface digitization devices. Comparability of the characteristics should be ensured. Method: Two laser light section scanners: DentaScope 11 and D200 were evaluated by means of the 'Sphere Test', that involves repeated measurements of a precision ball (radius: 6mm) according to a pre-defined protocol. The surface information was received as unmatched, overlapping point clouds and statistically processed with a newly developed software package. The standard deviation of all points as well as a measure for undercutting the equator were determined. Results: The standard deviation for the radius for D and S were 7.7 ( +/- 0.8) and 13.9 ( +/- 1.0) mu m respectively. The equator undercut elevations were -2.01 degrees and -0.25 degrees for scanner D and S respectively. Conclusion: Scanner D had a significantly higher accuracy than S (p<0.05), corresponding with the smaller pixel distance of the sensor. Both devices show adequate accuracy and reproducibility and have an adequate ability to detect the equator. The test is also suitable for calibration purposes.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 50 条
  • [31] A study on the machining accuracy of dental digital method focusing on dental inlay
    Bae, Eun-Jeong
    Jeong, Il-Do
    Kim, Woong-Chul
    Kim, Ji-Hwan
    JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (04): : 321 - 327
  • [32] DIGITIZERS FOR DATA-ENTRY
    HEARN, ED
    BYTE, 1986, 11 (12): : 261 - 266
  • [33] Advanced transient waveform digitizers
    Kleinfelder, S
    PARTICLE ASTROPHYSICS INSTRUMENTATION, 2003, 4858 : 316 - 326
  • [34] FLOW DATA ACQUISITION WITH FAST DIGITIZERS
    VANDANTZIG, R
    TENKATE, PU
    KOK, E
    KWAKKEL, E
    PEEK, HZ
    STEIJGER, J
    VISSCHERS, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 263 (01): : 212 - 214
  • [35] THE USE OF AUTOMATIC DIGITIZERS IN GEODATA PROCESSING
    DORN, M
    COMPUTERS & GEOSCIENCES, 1983, 9 (03) : 345 - 350
  • [36] TESTS FOR EVALUATING LASER FILM DIGITIZERS
    MEEDER, RJJ
    JAFFRAY, DA
    MUNRO, P
    MEDICAL PHYSICS, 1995, 22 (05) : 635 - 642
  • [37] Pulse shape discrimination with fast digitizers
    Cester, D.
    Lunardon, M.
    Nebbia, G.
    Stevanato, L.
    Viesti, G.
    Petrucci, S.
    Tintori, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 748 : 33 - 38
  • [38] Accuracy of digital surgical guides for dental implants
    Kim, Myoung-Ju
    Jeong, Jun Young
    Ryu, Jaeyoung
    Jung, Seunggon
    Park, Hong-Ju
    Oh, Hee-Kyun
    Kook, Min-Suk
    MAXILLOFACIAL PLASTIC AND RECONSTRUCTIVE SURGERY, 2022, 44 (01)
  • [39] Systematic distortions in magnetic position digitizers
    Birkfellner, W
    Watzinger, F
    Wanschitz, F
    Enislidis, G
    Kollmann, C
    Rafolt, D
    Nowotny, R
    MEDICAL PHYSICS, 1998, 25 (11) : 2242 - 2248
  • [40] DISPLACEMENT DIGITIZERS BASED ON MULTICOMPONENT PHOTORESISTORS
    BOGDANOVICH, VB
    PALAMARCHUK, AL
    SVECHNIKOV, SV
    MEASUREMENT TECHNIQUES USSR, 1986, 29 (06): : 505 - 507