TESTS FOR EVALUATING LASER FILM DIGITIZERS

被引:26
|
作者
MEEDER, RJJ
JAFFRAY, DA
MUNRO, P
机构
[1] UNIV WESTERN ONTARIO, DEPT MED BIOPHYS, LONDON, ON N6A 4L6, CANADA
[2] UNIV WESTERN ONTARIO, DEPT ONCOL, LONDON, ON N6A 4L6, CANADA
关键词
LASER FILM DIGITIZER; PORTAL IMAGING; FILM DIGITIZATION; FILM DENSITOMETRY; FILM DOSIMETRY; RADIATION THERAPY;
D O I
10.1118/1.597550
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A number of tests to evaluate the image transfer characteristics of laser film digitizers have been developed and these tests have been used to evaluate the performance of a Konica KFDR-S laser film digitizer. These tests were designed to be simple in nature and to use materials readily available in clinical departments. The tests examined (i) the geometric accuracy of the laser film digitizer; (ii) the linearity of the digitizer’s characteristic curve; (iii) the temporal/spatial response of the digitizer to abrupt changes in optical density; and (iv) the noise added by the digitizer to the digitized images. The tests were easy to use and could be performed in a short period of time. Results of the tests for the Konica laser film digitizer revealed several problems including minor geometric inaccuracies, structural noise added by a shading correction circuit in the digitizer, and spread of the laser beam before reaching the film plane, possibly caused by the f-theta lens of the digitizer. The light spread made the optical density of small, high density structures measured by the digitizer dependent upon the optical density of the surrounding regions. Therefore, under some circumstances, film digitization with the Konica laser film digitizer could lead to erroneous results. In addition, our measurements suggest that these problems are not unique to the Konica digitizer. Thus, the testing of laser film digitizers is recommended, especially if the digitizer is to be used for quantitative measurements. © 1995, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:635 / 642
页数:8
相关论文
共 50 条
  • [1] Film digitizers and laser printers
    Seibert, JA
    PRACTICAL DIGITAL IMAGING AND PACS, 1999, (25): : 107 - 133
  • [2] Quantitative optical densitometry with scanning-laser film digitizers
    Dempsey, JF
    Low, DA
    Kirov, AS
    Williamson, JF
    MEDICAL PHYSICS, 1999, 26 (08) : 1721 - 1731
  • [3] Quantitative optical densitometry with scanning-laser film digitizers
    Radiation Oncology Center, Mallinckrodt Institute of Radiology, Washington Univ. School of Medicine, St. Louis, MO 63110, United States
    Med. Phys., 8 (1721-1731):
  • [4] Quantitative assessment of physical characteristics of laser and CCD film digitizers in PACS applications
    Kang, W
    Han, D
    Jang, B
    Kim, J
    Yang, K
    Jung, H
    Yoo, S
    Kim, H
    MEDICAL PHYSICS, 2005, 32 (06) : 1915 - 1916
  • [5] LUMINANCE RANGE COMPRESSION FOR VIDEO FILM DIGITIZERS
    BEDNAREK, DR
    RUDIN, S
    WONG, R
    MEDICAL PHYSICS, 1991, 18 (02) : 198 - 205
  • [6] EVALUATING THE RELIABILITY OF ANGLE DIGITIZERS WITH ANALYSIS OF METROLOGIC MALFUNCTIONS
    DOMRACHEV, VG
    ISAEV, VM
    MEASUREMENT TECHNIQUES USSR, 1990, 33 (09): : 860 - 864
  • [7] Measurement methods for assessing the performance of radiographic film digitizers
    Hangiandreou, NJ
    OConnor, TJ
    Groth, DS
    RADIOLOGY, 1996, 201 : 799 - 799
  • [8] The use of film digitizers to assist radiology image management
    Honeyman, JC
    Frost, MM
    Staab, EV
    PACS DESIGN AND EVALUATION: ENGINEERING AND CLINICAL ISSUES - MEDICAL IMAGING 1996, 1996, 2711 : 224 - 231
  • [9] A TEST PATTERN FOR QUALITY-CONTROL OF LASER SCANNER AND CHARGE-COUPLED-DEVICE FILM DIGITIZERS
    HALPERN, EJ
    JOURNAL OF DIGITAL IMAGING, 1995, 8 (01) : 3 - 9
  • [10] CCD vs. laser: A comparative study of two types of x-ray film digitizers
    Gitlin, JN
    Drinkard, M
    MEDICAL IMAGING 1999 - PACS DESIGN AND EVALUATION: ENGINEERING AND CLINICAL ISSUES, 1999, 3662 : 438 - 443