Accuracy of dental digitizers

被引:0
|
作者
Vlaar, Simon T.
van der Zel, Jef M.
机构
[1] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Computerized Dent, NL-1066 EA Amsterdam, Netherlands
[2] Free Univ Amsterdam, NL-1066 EA Amsterdam, Netherlands
关键词
dental CAD/CAM; surface digitization device; laser-triangulation scanning; dental imaging; scanning accuracy;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The need for proper validation and verification methodology for CAD/CAM systems is imminent. CAD/CAM systems consisting of an optical impression system, design software and a fabrication machine have to perform to a certain level, whereby manufacturers need to prove the effectiveness of the system as a whole. However, especially when dental surface digitization devices are used as open, stand-alone applications in dental outsourcing, a reliable standard test for comparison is necessary. Purpose: This study evaluates a proposed test method to be used to quantify "digitizing quality" with respect to accuracy and reproducibility of two dental surface digitization devices. Comparability of the characteristics should be ensured. Method: Two laser light section scanners: DentaScope 11 and D200 were evaluated by means of the 'Sphere Test', that involves repeated measurements of a precision ball (radius: 6mm) according to a pre-defined protocol. The surface information was received as unmatched, overlapping point clouds and statistically processed with a newly developed software package. The standard deviation of all points as well as a measure for undercutting the equator were determined. Results: The standard deviation for the radius for D and S were 7.7 ( +/- 0.8) and 13.9 ( +/- 1.0) mu m respectively. The equator undercut elevations were -2.01 degrees and -0.25 degrees for scanner D and S respectively. Conclusion: Scanner D had a significantly higher accuracy than S (p<0.05), corresponding with the smaller pixel distance of the sensor. Both devices show adequate accuracy and reproducibility and have an adequate ability to detect the equator. The test is also suitable for calibration purposes.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 50 条
  • [41] Measurement of Absolute Phase Error of Digitizers
    Crotti, G.
    Delle Femine, A.
    Gallo, D.
    Giordano, D.
    Landi, C.
    Luiso, M.
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [42] DIGITIZERS ACQUIRE MORE ELECTRONICS - AND CAPABILITY
    YENCHARIS, L
    ELECTRONIC DESIGN, 1981, 29 (10) : 119 - 119
  • [43] Digitizers improve scanning acoustic microscopy
    Gregor, P
    Tate, G
    EE-EVALUATION ENGINEERING, 2005, 44 (01): : 16 - +
  • [44] Accuracy of digital surgical guides for dental implants
    Myoung-Ju Kim
    Jun Young Jeong
    Jaeyoung Ryu
    Seunggon Jung
    Hong-Ju Park
    Hee-Kyun Oh
    Min-Suk Kook
    Maxillofacial Plastic and Reconstructive Surgery, 44
  • [45] Firing temperature accuracy of four dental furnaces
    Haag, Per
    Ciber, Edina
    Derand, Tore
    SWEDISH DENTAL JOURNAL, 2011, 35 (01) : 25 - 31
  • [46] The Localization Accuracy of Electrically Evoked Dental Sensations
    Ab Ashaibi, Nuha
    Mason, Andrew Graham
    Hector, Mark Prichard
    Maillou, Pauline
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2025, 11 (01):
  • [47] A SURVEY OF THE ACCURACY OF REFERENCES IN 10 DENTAL JOURNALS
    NUCKLES, DB
    POPE, NN
    ADAMS, JD
    OPERATIVE DENTISTRY, 1993, 18 (01) : 28 - 32
  • [48] MECHANICAL AIDS FOR OBTAINING ACCURACY IN DENTAL ROENTGENOLOGY
    MCCORMACK, DW
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1950, 40 (02): : 144 - 153
  • [49] Compact Distributed Digitizers With Metrological Precision
    Houtzager, Ernest
    Hornecker, R.
    Rietveld, G.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (06) : 1653 - 1658
  • [50] Systematic distortions in magnetic position digitizers
    Dept. of Biomed. Eng. and Physics, Univ. of Vienna General Hospital, Vienna, Austria
    不详
    不详
    Med. Phys., 11 (2242-2248):