Accuracy of dental digitizers

被引:0
|
作者
Vlaar, Simon T.
van der Zel, Jef M.
机构
[1] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Computerized Dent, NL-1066 EA Amsterdam, Netherlands
[2] Free Univ Amsterdam, NL-1066 EA Amsterdam, Netherlands
关键词
dental CAD/CAM; surface digitization device; laser-triangulation scanning; dental imaging; scanning accuracy;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The need for proper validation and verification methodology for CAD/CAM systems is imminent. CAD/CAM systems consisting of an optical impression system, design software and a fabrication machine have to perform to a certain level, whereby manufacturers need to prove the effectiveness of the system as a whole. However, especially when dental surface digitization devices are used as open, stand-alone applications in dental outsourcing, a reliable standard test for comparison is necessary. Purpose: This study evaluates a proposed test method to be used to quantify "digitizing quality" with respect to accuracy and reproducibility of two dental surface digitization devices. Comparability of the characteristics should be ensured. Method: Two laser light section scanners: DentaScope 11 and D200 were evaluated by means of the 'Sphere Test', that involves repeated measurements of a precision ball (radius: 6mm) according to a pre-defined protocol. The surface information was received as unmatched, overlapping point clouds and statistically processed with a newly developed software package. The standard deviation of all points as well as a measure for undercutting the equator were determined. Results: The standard deviation for the radius for D and S were 7.7 ( +/- 0.8) and 13.9 ( +/- 1.0) mu m respectively. The equator undercut elevations were -2.01 degrees and -0.25 degrees for scanner D and S respectively. Conclusion: Scanner D had a significantly higher accuracy than S (p<0.05), corresponding with the smaller pixel distance of the sensor. Both devices show adequate accuracy and reproducibility and have an adequate ability to detect the equator. The test is also suitable for calibration purposes.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 50 条
  • [21] CHARTING ACCURACY IN NAVY DENTAL RECORDS
    ALEXANDER, RE
    MILITARY MEDICINE, 1991, 156 (01) : 8 - 10
  • [22] TIME DEPENDENT ACCURACY OF DENTAL RADIOMETERS
    Marovic, Danijela
    Matic, Sanja
    Kelic, Katarina
    Klaric, Eva
    Rakic, Mario
    Tarle, Zrinka
    ACTA CLINICA CROATICA, 2013, 52 (02) : 173 - 180
  • [23] AUTOMATIC DIGITIZERS FOR CAD CAM
    STOVER, RN
    MACHINE DESIGN, 1984, 56 (10) : 87 - 91
  • [24] 2 APPLICATIONS OF OPTICAL DIGITIZERS
    LOCKSHIN, RA
    BIOSCIENCE, 1986, 36 (03) : 184 - 186
  • [25] OPTICAL-SCANNING DIGITIZERS
    NAGY, G
    COMPUTER, 1983, 16 (05) : 13 - 24
  • [26] OPTICAL FIBERS FOR SCANNING DIGITIZERS
    PFERD, W
    STOCKER, GC
    BELL SYSTEM TECHNICAL JOURNAL, 1981, 60 (04): : 523 - 534
  • [27] Dimensional accuracy of dental casting obtained in epoxy resin and dental stone
    Rodrigues, DM
    Ribeiro, RF
    Rodrigues, RCS
    Frizzas, DG
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1154 - 1154
  • [28] VIDEO IMAGE DIGITIZERS REVISITED
    MCDONALD, CJ
    M D COMPUTING, 1989, 6 (06): : 326 - 328
  • [29] Evaluation of Accuracy and Completeness of Electronic Dental Records in a Dental School Setting
    Meisha, Dalia E.
    OPEN DENTISTRY JOURNAL, 2019, 13 : 520 - 525
  • [30] Accuracy of an autonomous dental implant robotic system in dental implant surgery
    Wu, Yu
    Zou, Shiqi
    Lv, Pin
    Wang, Xiao
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 764 - 770