Factors affecting accuracy of ventricular volume and ejection fraction measured by gated Tl-201 myocardial perfusion single photon emission computed tomography

被引:7
|
作者
Pai, Moonsun
Yang, You-Jung
Im, Ki Chun
Hong, Il Ki
Yun, Sung Cheol
Kang, Duk-Hyun
Song, Jae-Kwan
Moon, Dae Hyuk
机构
[1] Asan Med Ctr, Dept Nucl Med, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Dept Nucl Med, Seoul, South Korea
[3] Ewha Womans Univ, Div Nucl Med, Dept Radiol, Mokdong Hosp, Seoul, South Korea
[4] Asan Med Ctr, Div Epidemiol & Biostat, Seoul, South Korea
[5] Univ Ulsan, Coll Med, Div Cardiol, Asan Med Ctr, Seoul, South Korea
来源
关键词
left ventricular function; left ventricular ejection fraction; single photon emission-computed tomography; thallium-201;
D O I
10.1007/s10554-006-9098-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The electrocardiogram-gated single photon emission computed tomography (SPECT) measurement of left ventricular end-diastolic volume, end-systolic volume and ejection fraction may contain substantial errors. We evaluated whether patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. A total of 518 patients without perfusion defects on Tl-201 SPECT or coronary artery disease were studied. Left ventricular volume and ejection fraction were measured from echocardiography and adenosine stress/redistribution gated Tl-201 SPECT using commercially available software packages (QGS and 4D-MSPECT). We identified factors affecting the accuracy of gated SPECT via multiple linear regression analysis of the differences between echocardiography and gated SPECT. Gated SPECT analyzed with QGS underestimated end-diastolic and end-systolic volume, and overestimated ejection fraction, but 4D-MSPECT overestimated all those values (P < 0.001). Independent variables associated with increasing the difference in end-diastolic volume between echocardiography and gated SPECT were decreasing left ventricular end-diastolic wall thickness, decreasing body surface area, female sex and increasing end-diastolic volume (P < 0.001). Those for end-systolic volume were decreasing left ventricular end-systolic wall thickness, female sex, and decreasing end-systolic volume (P < 0.001). Increasing end-systolic wall thickness, male sex and decreasing age were independent determinants associated with an increased difference in ejection fraction (P < 0.001). Adenosine stress SPECT showed significantly higher end-diastolic and end-systolic volume values and a lower ejection fraction than did redistribution SPECT (P < 0.001). Patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. Modification of gated SPECT measurements by taking account of these factors would lead to reduce systemic errors.
引用
收藏
页码:671 / 681
页数:11
相关论文
共 50 条
  • [31] Validation of left ventricular (LV) volume and ejection fraction (EF) measurements with res TL-201 gated SPECT.
    Daou, D
    Colin, P
    Fourme, T
    Benada, A
    Pointurier, I
    Dinanian, S
    Helal, B
    Prigent, A
    Slama, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1067 - 1067
  • [32] Comparison of two software in gated myocardial perfusion single photon emission tomography, for the measurement of left ventricular volumes and ejection fraction, in patients with and without perfusion defects
    Kakhki, Vahid Reza Dabbagh
    Zakavi, Seyed Rasoul
    Sadeghi, Ramin
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2007, 10 (01): : 19 - 23
  • [33] Validation of left ventricular (LV) volume and ejection fraction (EF) measurements with rest Tl-201 gated SPECT.
    Daou, D
    Colin, P
    Fourme, T
    Helal, BO
    Benada, A
    Pointurier, I
    Saidi, L
    Dinanian, S
    Prigent, A
    Slama, M
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 163P - 164P
  • [34] Prognostic value of post-stress left ventricular volume and ejection fraction by gated myocardial perfusion single photon emission computed tomography in women: Gender related differences in normal limits and outcome
    Sharir, T
    Germano, G
    Kang, XP
    Cohen, I
    Friedman, JD
    Berman, DS
    CIRCULATION, 2002, 106 (19) : 523 - 523
  • [35] QUANTIFICATION OF MYOCARDIAL INFARCT SIZE BY TL-201 SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY - EXPERIMENTAL VALIDATION IN THE DOG
    PRIGENT, F
    MADDAHI, J
    GARCIA, EV
    SATOH, Y
    VANTRAIN, K
    BERMAN, DS
    CIRCULATION, 1986, 74 (04) : 852 - 861
  • [36] TL-201 SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IN THE EVALUATION OF LUNG AND MEDIASTINAL DISEASE
    NAMBA, R
    NARABAYASI, I
    SUEYOSI, K
    ADACHI, I
    UTSUNOMIYA, K
    SAIKA, Y
    NAKATA, Y
    TATSU, Y
    HOU, Y
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P221 - P221
  • [37] QUANTITATIVE-ANALYSIS OF TL-201 MYOCARDIAL EMISSION COMPUTED-TOMOGRAPHY
    OKADA, M
    KAWAI, N
    YAMAMOTO, S
    MATSUSHIMA, H
    KATO, R
    TANAHASHI, Y
    SOTOBATA, I
    OBATA, Y
    SAKUMA, S
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P86 - P86
  • [38] DIAGNOSTICS OF DILATED CARDIOMYOPATHY, USING TL-201 SINGLE-PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    HOFFMEISTER, HM
    MULLERSCHAUENBURG, W
    RIESNER, C
    HANKE, H
    KARSCH, KR
    FEINE, U
    SEIPEL, L
    ZEITSCHRIFT FUR KARDIOLOGIE, 1987, 76 : 16 - 16
  • [39] Correlation between stress and rest left ventricular ejection fraction in gated single photon emission computed tomography (SPECT) with the extent and severity of perfusion abnormalities
    Quinon, A. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S282 - S282
  • [40] Accuracy of gated perfusion single-photon emission tomography for left ventricular ejection fraction assessment in the presence of large perfusion defects: Correlation with cardiac magnetic resonance
    Chen, K
    Tan, RS
    Keng, F
    Cheah, FK
    Tan, KP
    Tan, BS
    Lim, YL
    Chua, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 394A - 394A