Factors affecting accuracy of ventricular volume and ejection fraction measured by gated Tl-201 myocardial perfusion single photon emission computed tomography

被引:7
|
作者
Pai, Moonsun
Yang, You-Jung
Im, Ki Chun
Hong, Il Ki
Yun, Sung Cheol
Kang, Duk-Hyun
Song, Jae-Kwan
Moon, Dae Hyuk
机构
[1] Asan Med Ctr, Dept Nucl Med, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Dept Nucl Med, Seoul, South Korea
[3] Ewha Womans Univ, Div Nucl Med, Dept Radiol, Mokdong Hosp, Seoul, South Korea
[4] Asan Med Ctr, Div Epidemiol & Biostat, Seoul, South Korea
[5] Univ Ulsan, Coll Med, Div Cardiol, Asan Med Ctr, Seoul, South Korea
来源
关键词
left ventricular function; left ventricular ejection fraction; single photon emission-computed tomography; thallium-201;
D O I
10.1007/s10554-006-9098-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The electrocardiogram-gated single photon emission computed tomography (SPECT) measurement of left ventricular end-diastolic volume, end-systolic volume and ejection fraction may contain substantial errors. We evaluated whether patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. A total of 518 patients without perfusion defects on Tl-201 SPECT or coronary artery disease were studied. Left ventricular volume and ejection fraction were measured from echocardiography and adenosine stress/redistribution gated Tl-201 SPECT using commercially available software packages (QGS and 4D-MSPECT). We identified factors affecting the accuracy of gated SPECT via multiple linear regression analysis of the differences between echocardiography and gated SPECT. Gated SPECT analyzed with QGS underestimated end-diastolic and end-systolic volume, and overestimated ejection fraction, but 4D-MSPECT overestimated all those values (P < 0.001). Independent variables associated with increasing the difference in end-diastolic volume between echocardiography and gated SPECT were decreasing left ventricular end-diastolic wall thickness, decreasing body surface area, female sex and increasing end-diastolic volume (P < 0.001). Those for end-systolic volume were decreasing left ventricular end-systolic wall thickness, female sex, and decreasing end-systolic volume (P < 0.001). Increasing end-systolic wall thickness, male sex and decreasing age were independent determinants associated with an increased difference in ejection fraction (P < 0.001). Adenosine stress SPECT showed significantly higher end-diastolic and end-systolic volume values and a lower ejection fraction than did redistribution SPECT (P < 0.001). Patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. Modification of gated SPECT measurements by taking account of these factors would lead to reduce systemic errors.
引用
收藏
页码:671 / 681
页数:11
相关论文
共 50 条
  • [41] MORPHOLOGICAL ASSESSMENT OF LEFT-VENTRICULAR WALL AND VENTRICULAR ANEURYSM BY TL-201 MYOCARDIAL EMISSION COMPUTED-TOMOGRAPHY
    NAKATA, T
    TANAKA, S
    MURAKAMI, H
    UNO, K
    NOTO, T
    TSUDA, T
    KUBOTA, M
    MORITA, K
    IIMURA, O
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1988, 52 (07): : 589 - 596
  • [42] Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: Comparison of 4 software programs
    Nakajima, K
    Higuchi, T
    Taki, J
    Kawano, M
    Tonami, N
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (10) : 1571 - 1578
  • [43] Comparison of left ventricular ejection fraction by single photon computed tomographic myocardial perfusion imaging versus coronary computed tomography angiography
    Rajdev, Archana
    Aronow, Wilbert S.
    Lai, Hoang M.
    Ravipati, Gautham
    DeLuca, Albert J.
    Weiss, Melvin B.
    Belkin, Robert N.
    ARCHIVES OF MEDICAL SCIENCE, 2009, 5 (01) : 28 - 31
  • [44] Accuracy of left ventricular ejection fraction determined by gated myocardial perfusion SPECT with Tl-201 and Tc-99m sestamibi: Comparison with first-pass radionuclide angiography
    He Z.-X.
    Cwajg E.
    Preslar J.S.
    Mahmarian J.J.
    Verani M.S.
    Journal of Nuclear Cardiology, 1999, 6 (4) : 412 - 417
  • [45] Accuracy of left ventricular ejection fraction determined by gated myocardial perfusion SPECT with Tl-201 and Tc-99m sestamibi: Comparison with first-pass radionuclide angiography
    He, ZX
    Cwajg, E
    Preslar, JS
    Mahmarian, JJ
    Verani, MS
    JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (04) : 412 - 417
  • [46] ASSESSMENT OF SYSTOLIC THICKENING WITH TL-201 ECG-GATED SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY - A PARAMETER FOR LOCAL LEFT-VENTRICULAR FUNCTION
    MOCHIZUKI, T
    MURASE, K
    FUJIWARA, Y
    TANADA, S
    HAMAMOTO, K
    TAUXE, WN
    JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (08) : 1496 - 1500
  • [47] MYOCARDIAL PERFUSION DAMAGE AFTER MEDIASTINAL IRRADIATION FOR HODGKINS-DISEASE - A TL-201 SINGLE PHOTON-EMISSION TOMOGRAPHY STUDY
    MAUNOURY, C
    PIERGA, JY
    VALETTE, H
    TCHERNIA, G
    COSSET, JM
    DESGREZ, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1992, 19 (10): : 871 - 873
  • [48] QUANTIFICATION OF TL-201 MYOCARDIAL SINGLE PHOTON-EMISSION CT (SPECT)
    DOI, O
    MITSUDO, K
    FUJINO, T
    MATSUNAGA, K
    NISHIHARA, Y
    AWA, J
    GOTO, T
    HASE, T
    KIN, M
    KADOTA, K
    SAKAMOTO, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1986, 50 (08): : 777 - 777
  • [49] ALTERATIONS IN MYOCARDIAL TL-201 DISTRIBUTION IN PATIENTS WITH CHRONIC SYSTEMIC HYPERTENSION UNDERGOING SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    DEPUEY, EG
    GUERTLERKRAWCZYNSKA, E
    PERKINS, JV
    ROBBINS, WL
    WHELCHEL, JD
    CLEMENTS, SD
    AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (04): : 234 - 238
  • [50] DIAGNOSIS OF RIGHT VENTRICULAR PRESSURE OR VOLUME OVERLOAD BY TL-201 MYOCARDIAL PERFUSION SCAN
    KHAJA, F
    ALAM, M
    GOLDSTEIN, S
    ANBE, D
    MARKS, D
    JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 1978, 10 : 45 - 45