Factors affecting accuracy of ventricular volume and ejection fraction measured by gated Tl-201 myocardial perfusion single photon emission computed tomography

被引:7
|
作者
Pai, Moonsun
Yang, You-Jung
Im, Ki Chun
Hong, Il Ki
Yun, Sung Cheol
Kang, Duk-Hyun
Song, Jae-Kwan
Moon, Dae Hyuk
机构
[1] Asan Med Ctr, Dept Nucl Med, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Dept Nucl Med, Seoul, South Korea
[3] Ewha Womans Univ, Div Nucl Med, Dept Radiol, Mokdong Hosp, Seoul, South Korea
[4] Asan Med Ctr, Div Epidemiol & Biostat, Seoul, South Korea
[5] Univ Ulsan, Coll Med, Div Cardiol, Asan Med Ctr, Seoul, South Korea
来源
关键词
left ventricular function; left ventricular ejection fraction; single photon emission-computed tomography; thallium-201;
D O I
10.1007/s10554-006-9098-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The electrocardiogram-gated single photon emission computed tomography (SPECT) measurement of left ventricular end-diastolic volume, end-systolic volume and ejection fraction may contain substantial errors. We evaluated whether patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. A total of 518 patients without perfusion defects on Tl-201 SPECT or coronary artery disease were studied. Left ventricular volume and ejection fraction were measured from echocardiography and adenosine stress/redistribution gated Tl-201 SPECT using commercially available software packages (QGS and 4D-MSPECT). We identified factors affecting the accuracy of gated SPECT via multiple linear regression analysis of the differences between echocardiography and gated SPECT. Gated SPECT analyzed with QGS underestimated end-diastolic and end-systolic volume, and overestimated ejection fraction, but 4D-MSPECT overestimated all those values (P < 0.001). Independent variables associated with increasing the difference in end-diastolic volume between echocardiography and gated SPECT were decreasing left ventricular end-diastolic wall thickness, decreasing body surface area, female sex and increasing end-diastolic volume (P < 0.001). Those for end-systolic volume were decreasing left ventricular end-systolic wall thickness, female sex, and decreasing end-systolic volume (P < 0.001). Increasing end-systolic wall thickness, male sex and decreasing age were independent determinants associated with an increased difference in ejection fraction (P < 0.001). Adenosine stress SPECT showed significantly higher end-diastolic and end-systolic volume values and a lower ejection fraction than did redistribution SPECT (P < 0.001). Patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. Modification of gated SPECT measurements by taking account of these factors would lead to reduce systemic errors.
引用
收藏
页码:671 / 681
页数:11
相关论文
共 50 条
  • [21] “W-shaped” volume curve with gated myocardial perfusion single photon emission computed tomography
    Tokuo Kasai
    E. Gordon DePuey
    Irwin Sponder
    Annals of Nuclear Medicine, 2005, 19 : 59 - 64
  • [22] W-shaped volume curve with gated myocardial perfusion single photon emission computed tomography
    Kasai, T
    DePuey, EG
    Sponder, I
    ANNALS OF NUCLEAR MEDICINE, 2005, 19 (01) : 59 - 64
  • [23] Left Ventricular Ejection Fraction Assessment by Tl-201 Gated SPECT: A Comparison With Echocardiography
    Harpaz, David
    Asman, Arik
    Kuperstein, Rafael
    Boaz, Mona
    Chouraqui, Pierre
    CLINICAL CARDIOLOGY, 2010, 33 (03) : E56 - E62
  • [24] Clinical factors determining the variability of left ventricular ejection fraction measured with 201Tl myocardial gated SPECT.
    Daou, D
    Coaguila, C
    Helal, BO
    Carel, I
    Fourme, T
    Slama, M
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 178P - 178P
  • [25] Usefulness of endocoronary electrocardiogram in the detection of myocardial viability and comparison with single-photon emission computed tomography Tl-201
    Ferrari, E
    Vidal, R
    Migneco, O
    Thiry, M
    Baudouy, M
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (10): : 1279 - +
  • [26] Worsening of left ventricular ejection fraction induced by dipyridamole on Tl-201 gated myocardial perfusion imaging predicts significant coronary artery disease
    Hung G.-U.
    Lee K.-W.
    Chen C.-P.
    Yang K.-T.
    Lin W.-Y.
    Journal of Nuclear Cardiology, 2006, 13 (2) : 225 - 232
  • [27] ESTIMATED LEFT-VENTRICULAR EJECTION FRACTION IN REST TL-201 PERFUSION IMAGING
    GANDSMAN, EJ
    BOUGH, EW
    KORR, KS
    TYSON, IB
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) : P43 - P43
  • [28] MYOCARDIAL PERFUSION ABNORMALITIES IN PATIENTS WITH HYPERTROPHIC CARDIOMYOPATHY - ASSESSMENT WITH TL-201 EMISSION COMPUTED-TOMOGRAPHY
    OGARA, PT
    BONOW, RO
    MARON, BJ
    DAMSKE, BA
    VANLINGEN, A
    BACHARACH, SL
    LARSON, SM
    EPSTEIN, SE
    CIRCULATION, 1987, 76 (06) : 1214 - 1223
  • [29] Assessment of myocardial perfusion by intravenous administration of levovist:: A comparison with 201Tl single photon emission computed tomography
    Muro, T
    Teragaki, M
    Yamagishi, H
    Watanabe, H
    Ujino, K
    Hirata, K
    Otsuka, R
    Daimon, R
    Takeuchi, K
    Yoshikawa, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 426A - 426A
  • [30] Repeatability of left ventricular ejection fraction and volume measurement for 99mTc-tetrofosmin gated single photon emission computed tomography (SPECT)
    Thorley, PJ
    Smith, JM
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (04) : 345 - 349