W-shaped volume curve with gated myocardial perfusion single photon emission computed tomography

被引:5
|
作者
Kasai, T [1 ]
DePuey, EG [1 ]
Sponder, I [1 ]
机构
[1] Columbia Univ, Coll Phys & Surg, Div Nucl Med, Dept Radiol,St Lukes Roosevelt Hosp Ctr, New York, NY 10027 USA
关键词
gating errors; myocardial SPECT; left ventricular function; volume curve; time-activity curve;
D O I
10.1007/BF02986338
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Gating errors (GEs) with ECG gated myocardial SPECT (G-SPECT) may occur irrespective of the presence or absence of arrhythmias. We evaluated the impact of GEs on both reconstructed tomograms and left ventricular ejection fraction (LVEF) derived from G-SPECT, and searched for clues to identify these errors. Methods: We studied 2 GE patients, 10 normal subjects (NLs), and 10 atrial fibrillation patients. Stress technetium-99m sestamibi G-SPECT was performed. Left ventricular (LV) contraction was evaluated in the beating slices. LVEF was calculated with G-SPECT using QGS (Cedars-Sinai, Los Angels) and p-FAST (Sapporo Medical University, Japan), and compared with that obtained by echocardiography (ECHO). LV volume curves were created by QGS and p-FAST. ne heart rates (HRs) were calculated from the acquired images, and compared with their resting HRs. The mean count density of the myocardium was measured and time-activity curves were created. Results: In patients with GEs, bi-phasic LV contraction was demonstrated with fading-out towards end-diastole. G-SPECT underestimated LVEF compared to ECHO by 10% or more. The volume curves appeared "W-shaped." The HRs from the images were slower than the resting HRs. The count density decrement from frame #1 to #8 was larger than that of NLs. The time-activity curves were different in shape from those of NLs. Conclusions: G-SPECT underestimates LVEF in patients with GEs. These errors can be identified with a combination of visual inspection of beating slices, time-volume curves, and time-activity curves. Monitoring the HR is a clue for anticipating and avoiding these errors.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 50 条
  • [1] “W-shaped” volume curve with gated myocardial perfusion single photon emission computed tomography
    Tokuo Kasai
    E. Gordon DePuey
    Irwin Sponder
    Annals of Nuclear Medicine, 2005, 19 : 59 - 64
  • [2] Gated Myocardial Perfusion Single-Photon Emission Computed Tomography Imaging with Multifocal Collimator
    Takahashi, K.
    Takeuchi, T.
    Hosokai, Y.
    Odagiri, H.
    Usui, A.
    Saito, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S659 - S659
  • [3] Myocardial perfusion and function single photon emission computed tomography
    Christopher L. Hansen
    Richard A. Goldstein
    Daniel S. Berman
    Keith B. Churchwell
    C. David Cooke
    James R. Corbett
    S. James Cullom
    Seth T. Dahlberg
    James R. Galt
    Ravi K. Garg
    Gary V. Heller
    Mark C. Hyun
    Lynne L. Johnson
    Benjamin D. McCallister
    Raymond Taillefer
    Parker Ward
    John J. Mahmarian
    Journal of Nuclear Cardiology, 2006, 13 (6) : e97 - e120
  • [4] Myocardial perfusion and function: Single photon emission computed tomography
    Christopher L. Hansen
    Richard A. Goldstein
    Olakunle O. Akinboboye
    Daniel S. Berman
    Elias H. Botvinick
    Keith B. Churchwell
    C. David Cooke
    James R. Corbett
    S. James Cullom
    Seth T. Dahlberg
    Regina S. Druz
    Edward P. Ficaro
    James R. Galt
    Ravi K. Garg
    Guido Germano
    Gary V. Heller
    Milena J. Henzlova
    Mark C. Hyun
    Lynne L. Johnson
    April Mann
    Benjamin D. McCallister
    Robert A. Quaife
    Terrence D. Ruddy
    Senthil N. Sundaram
    Raymond Taillefer
    R. Parker Ward
    John J. Mahmarian
    Journal of Nuclear Cardiology, 2007, 14 (6) : e39 - e60
  • [5] Prognostic value of gated myocardial perfusion single photon emission computed tomography in women versus men
    Sharir, T
    Germano, G
    Friedman, JD
    Agafitei, D
    Cohen, I
    Miranda, RS
    Berman, DS
    CIRCULATION, 2000, 102 (18) : 544 - 544
  • [6] Usefulness of phase analysis on ECG gated single photon emission computed tomography myocardial perfusion imaging
    Kuronuma, Keiichiro
    Matsumoto, Naoya
    Van Kriekinge, Serge D.
    Slomka, Piotr J.
    Berman, Daniel S.
    JOURNAL OF CARDIOLOGY, 2023, 82 (02) : 87 - 92
  • [7] Influence of myocardial count on phase dyssynchrony analysis of gated myocardial perfusion single-photon emission computed tomography
    Kita, Akinobu
    Onoguchi, Masahisa
    Shibutani, Takayuki
    Sugimoto, Katsuya
    Kosaka, Nobuyuki
    Adachi, Toshiki
    Kimura, Hirohiko
    NUCLEAR MEDICINE COMMUNICATIONS, 2019, 40 (02) : 124 - 130
  • [8] Myocardial perfusion with single-photon emission computed tomography, multidetector computed tomography, or neither?
    Paolo Raggi
    G. B. John Mancini
    Journal of Nuclear Cardiology, 2017, 24 : 1722 - 1724
  • [9] Myocardial perfusion with single-photon emission computed tomography, multidetector computed tomography, or neither?
    Raggi, Paolo
    Mancini, G. B. John
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (05) : 1722 - 1724
  • [10] Technical aspects and errors of triggering and synchronization in gated single photon emission computed tomography myocardial perfusion imaging
    Qutbi, Mohsen
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2020, 35 (02): : 154 - 159