Comparison of two software in gated myocardial perfusion single photon emission tomography, for the measurement of left ventricular volumes and ejection fraction, in patients with and without perfusion defects

被引:1
|
作者
Kakhki, Vahid Reza Dabbagh [1 ]
Zakavi, Seyed Rasoul [1 ]
Sadeghi, Ramin [1 ]
机构
[1] Mashhad Univ Med Sci, Dept Nucl Med, Imam Reza Hosp, Mashhad, Iran
来源
HELLENIC JOURNAL OF NUCLEAR MEDICINE | 2007年 / 10卷 / 01期
关键词
gated SPET; left ventricular volume; ejection fraction; perfusion defects; summed rest score;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Emory cardiac toolbox (ECTb) and quantitative gated single photon emission tomography - SPET (QGS) software are the two most often used techniques for automatic calculation of left ventricular volumes (LVV) and ejection fraction (LVEF). Few studies have shown that these software are not interchangeable, however the effect of perfusion defects on performance of these software has not been widely studied. The aim of this study was to compare the performance of QGS and ECTb for the calculation of LVEF, end-systolic volume (ESV) and end-diastolic volume (EDV) in patients with normal and abnormal myocardial perfusion. One hundred and forty-four consecutive patients with suspected coronary artery disease underwent a two-day protocol with dipyridamole stress/rest gated technetium-99m-methoxy isobutyl isonitrile (Tc-99m-sestamibi) myocardial perfusion SPET (GSPET) (8 gates/cardiac cycles). Rest GSPET scintiscan findings were analyzed using QGS and ECTb. Correlation between the results of QGS and ECTb was greater than 90%. In patients with no perfusion defects, EDV and LVEF using ECTb, were significantly higher than using QGS (P<0.001), whereas no significant difference was noticed in ESV (P=0.741). In patients with perfusion defects, also ECTb yielded significantly higher values for EDV, ESV and LVEF than QGS (P<0.001). In tomograms of patients with perfusion defects, mean differences of EDV and ESV between the two software, were significantly higher than in tomograms of patients without defects (P<0.001), while for LVEF this difference was not significant (P=0.093). Patients were classified into three subgroups based on the summed rest score (SRS); G1: patients with SRS:53 (n=109), G2: patients with 4 <= SRS <= 8 (n=13) and G3: patients with SRS >= 9 (n=22). One-way ANOVA showed that the mean differences of EDV and ESV values between ECTb and QGS between the subgroups were significant (P<0.001 for both parameters), while no significant difference was noticed between the subgroups, as for the mean difference of LVEF, calculated by the two software (P=0.07). By increasing SRS, the EDV and ESV values were overestimated to a higher level by the ECTb as compared to the QGS software. Linear regression analysis showed that the difference in LVV values, between the two software increased, when SRS also increased (P<0.001). In conclusion, correlation between QGS and ECTb, software was very good both in patients with and without perfusion defects. In patients with perfusion defects, calculated LVEF, ESV and EDV values are higher using ECTb compared to the QGS software. However, the more extensive the perfusion defect was, the greater the difference of LVV between these two software. For the follow up of patients, we suggest the use of a single software either QGS or ECTb, for serial measurements of LV function.
引用
收藏
页码:19 / 23
页数:5
相关论文
共 50 条
  • [1] Reliability of left ventricular ejection fraction calculated with gated myocardial perfusion single photon emission computed tomography in patients with extensive perfusion defect
    Harisankar, Chidambaram Natrajan Balasubramanian
    Mittal, Bhagwant Rai
    Kamaleshwaran, Koramadai Karuppuswamy
    Parmar, Madan
    Bhattacharya, Anish
    Singh, Baljinder
    Mahajan, Rajiv
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (06) : 503 - 507
  • [2] Gated myocardial perfusion tomography versus gated blood pool tomography for the calculation of left ventricular volumes and ejection fraction
    Christian Vanhove
    Natasha Walgraeve
    Frank De Geeter
    Philippe R. Franken
    European Journal of Nuclear Medicine and Molecular Imaging, 2002, 29 : 735 - 741
  • [3] Gated myocardial perfusion tomography versus gated blood pool tomography for the calculation of left ventricular volumes and ejection fraction
    Vanhove, C
    Walgraeve, N
    De Geeter, F
    Franken, PR
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (06) : 735 - 741
  • [4] Comparison between three different gated myocardial perfusion software programs in measuring left ventricular ejection fraction and volumes
    Alexiou, S.
    Georgoulias, P.
    Valotassiou, V.
    Tsougos, I.
    Psimadas, D.
    Ziaka, A.
    Baniora, E.
    Ziangas, C.
    Lakiotis, V.
    Alexopoulos, D.
    Apostolopoulos, D.
    Vassilakos, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S549 - S549
  • [5] Accuracy of gated perfusion single-photon emission tomography for left ventricular ejection fraction assessment in the presence of large perfusion defects: Correlation with cardiac magnetic resonance
    Chen, K
    Tan, RS
    Keng, F
    Cheah, FK
    Tan, KP
    Tan, BS
    Lim, YL
    Chua, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 394A - 394A
  • [6] Left ventricular ejection fraction and volumes from gated single photon emission tomographic myocardial perfusion images: Comparison between two algorithms working in three-dimensional space
    Hendrik Everaert
    Axel Bossuyt
    Philippe R. Franken
    Journal of Nuclear Cardiology, 1997, 4 : 472 - 476
  • [7] Left ventricular ejection fraction and volumes from gated single photon emission tomographic myocardial perfusion images: Comparison between two algorithms working in three-dimensional space
    Everaert, H
    Bossuyt, A
    Franken, PR
    JOURNAL OF NUCLEAR CARDIOLOGY, 1997, 4 (06) : 472 - 476
  • [8] Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT
    Lum, DP
    Coel, MN
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (03) : 259 - 266
  • [9] Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography
    Sharir, T
    Germano, G
    Kavanagh, PB
    Lai, SH
    Cohen, I
    Lewin, HC
    Friedman, JD
    Zellweger, MJ
    Berman, DS
    CIRCULATION, 1999, 100 (10) : 1035 - 1042
  • [10] Gated myocardial perfusion single photon emission tomography (GSPECT) for the evaluation of left ventricular ejection fraction in CAD patients with previous myocardial infarction before and after PTCA.
    Giubbini, RM
    Terzi, AA
    Rossini, PL
    Magri, GC
    Milan, E
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 44P - 44P