Comparison of two software in gated myocardial perfusion single photon emission tomography, for the measurement of left ventricular volumes and ejection fraction, in patients with and without perfusion defects

被引:1
|
作者
Kakhki, Vahid Reza Dabbagh [1 ]
Zakavi, Seyed Rasoul [1 ]
Sadeghi, Ramin [1 ]
机构
[1] Mashhad Univ Med Sci, Dept Nucl Med, Imam Reza Hosp, Mashhad, Iran
来源
HELLENIC JOURNAL OF NUCLEAR MEDICINE | 2007年 / 10卷 / 01期
关键词
gated SPET; left ventricular volume; ejection fraction; perfusion defects; summed rest score;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Emory cardiac toolbox (ECTb) and quantitative gated single photon emission tomography - SPET (QGS) software are the two most often used techniques for automatic calculation of left ventricular volumes (LVV) and ejection fraction (LVEF). Few studies have shown that these software are not interchangeable, however the effect of perfusion defects on performance of these software has not been widely studied. The aim of this study was to compare the performance of QGS and ECTb for the calculation of LVEF, end-systolic volume (ESV) and end-diastolic volume (EDV) in patients with normal and abnormal myocardial perfusion. One hundred and forty-four consecutive patients with suspected coronary artery disease underwent a two-day protocol with dipyridamole stress/rest gated technetium-99m-methoxy isobutyl isonitrile (Tc-99m-sestamibi) myocardial perfusion SPET (GSPET) (8 gates/cardiac cycles). Rest GSPET scintiscan findings were analyzed using QGS and ECTb. Correlation between the results of QGS and ECTb was greater than 90%. In patients with no perfusion defects, EDV and LVEF using ECTb, were significantly higher than using QGS (P<0.001), whereas no significant difference was noticed in ESV (P=0.741). In patients with perfusion defects, also ECTb yielded significantly higher values for EDV, ESV and LVEF than QGS (P<0.001). In tomograms of patients with perfusion defects, mean differences of EDV and ESV between the two software, were significantly higher than in tomograms of patients without defects (P<0.001), while for LVEF this difference was not significant (P=0.093). Patients were classified into three subgroups based on the summed rest score (SRS); G1: patients with SRS:53 (n=109), G2: patients with 4 <= SRS <= 8 (n=13) and G3: patients with SRS >= 9 (n=22). One-way ANOVA showed that the mean differences of EDV and ESV values between ECTb and QGS between the subgroups were significant (P<0.001 for both parameters), while no significant difference was noticed between the subgroups, as for the mean difference of LVEF, calculated by the two software (P=0.07). By increasing SRS, the EDV and ESV values were overestimated to a higher level by the ECTb as compared to the QGS software. Linear regression analysis showed that the difference in LVV values, between the two software increased, when SRS also increased (P<0.001). In conclusion, correlation between QGS and ECTb, software was very good both in patients with and without perfusion defects. In patients with perfusion defects, calculated LVEF, ESV and EDV values are higher using ECTb compared to the QGS software. However, the more extensive the perfusion defect was, the greater the difference of LVV between these two software. For the follow up of patients, we suggest the use of a single software either QGS or ECTb, for serial measurements of LV function.
引用
收藏
页码:19 / 23
页数:5
相关论文
共 50 条
  • [41] Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular volumes and ejection fraction in patients with idiopathic dilated cardiomyopathy
    Petri Sipola
    Keijo Peuhkurinen
    Esko Vanninen
    The International Journal of Cardiovascular Imaging, 2011, 27 : 629 - 634
  • [42] Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular volumes and ejection fraction in patients with idiopathic dilated cardiomyopathy
    Sipola, Petri
    Peuhkurinen, Keijo
    Vanninen, Esko
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (04): : 629 - 634
  • [43] Factors affecting the measurement of left ventricular ejection fraction in myocardial perfusion imaging
    Lavender, Frances M.
    Meades, Richard T.
    Al-Nahhas, Adil
    Nijran, Kuldip S.
    NUCLEAR MEDICINE COMMUNICATIONS, 2009, 30 (05) : 350 - 355
  • [44] Myocardial stunning-induced left ventricular dyssynchrony on gated single-photon emission computed tomography myocardial perfusion imaging
    Jiang, Zhixin
    Tang, Haipeng
    Shi, Jianzhou
    Zhou, Yanli
    Wang, Cheng
    Li, Dianfu
    Shan, Qijun
    Zhou, Weihua
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (08) : 725 - 731
  • [45] Left ventricular ejection fraction and volumes on rest gated 201TI perfusion SPECT:: Comparison with two-dimensional echocardiography
    Patel, CD
    Nadig, MR
    Kurien, S
    Barai, S
    Narang, R
    Malhotra, A
    NUCLEAR MEDICINE COMMUNICATIONS, 2006, 27 (05) : 425 - 429
  • [46] Impact of ischemia on left ventricular dyssynchrony by phase analysis of gated single photon emission computed tomography myocardial perfusion imaging
    AlJaroudi, Wael
    Koneru, Jayanth
    Heo, Jaekyeong
    Iskandrian, Ami E.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (01) : 36 - 42
  • [47] Impact of Ischemia on Left Ventricular Dyssynchrony by Phase Analysis of Gated Single Photon Emission Computed Tomography Myocardial Perfusion Imaging
    Aljaroudi, Wael
    Koneru, Jayanth
    Heo, Jaekyeong
    Iskandrian, Ami E.
    CIRCULATION, 2010, 122 (21)
  • [48] Impact of ischemia on left ventricular dyssynchrony by phase analysis of gated single photon emission computed tomography myocardial perfusion imaging
    Wael AlJaroudi
    Jayanth Koneru
    Jaekyeong Heo
    Ami E. Iskandrian
    Journal of Nuclear Cardiology, 2011, 18 : 36 - 42
  • [49] Determination of left ventricular volumes and ejection fraction: A comparison between gated SPECT myocardial perfusion scintigraphy and quantitative 3D-echocardiography.
    Cittanti, C
    Mele, D
    Colamussi, P
    Giganti, M
    Dafermou, A
    Uccelli, L
    Alboni, P
    Piffanelli, A
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 172P - 172P
  • [50] Prone Versus Supine Myocardial Gated Spect (GSPECT) In The Evaluation of Ventricular Volumes, Ejection Fraction And Myocardial Perfusion
    Amer, H. A. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S306 - S306