Reliability of left ventricular ejection fraction calculated with gated myocardial perfusion single photon emission computed tomography in patients with extensive perfusion defect

被引:10
|
作者
Harisankar, Chidambaram Natrajan Balasubramanian [1 ]
Mittal, Bhagwant Rai [1 ]
Kamaleshwaran, Koramadai Karuppuswamy [1 ]
Parmar, Madan [1 ]
Bhattacharya, Anish [1 ]
Singh, Baljinder [1 ]
Mahajan, Rajiv [2 ]
机构
[1] Postgrad Inst Med Educ & Res, Dept Nucl Med, Chandigarh 160012, India
[2] Postgrad Inst Med Educ & Res, Dept Cardiol, Chandigarh 160012, India
关键词
echocardiography; ejection fraction; gated single photon emission computed tomography; radionuclide ventriculography; BLOOD-POOL TOMOGRAPHY; AUTOMATIC QUANTIFICATION; RADIONUCLIDE ANGIOGRAPHY; NORMAL LIMITS; SPECT; TL-201; VOLUMES; ACCURACY; ECHOCARDIOGRAPHY; IMAGES;
D O I
10.1097/MNM.0b013e328342b97e
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction Gated myocardial perfusion scintigraphy (g-MPS) provides functional information on the left ventricle (LV) apart from the perfusion status. Computer algorithm-based LV ejection fraction (EF) calculated from resting g-MPS has been found to be reliable in patients with normal perfusion. However, its role in patients with extensive perfusion defects is not clear. Aim To find the reliability of LVEF calculated from resting g-MPS in patients with extensive perfusion defects (>25% of LV myocardium) and to correlate this with echocardiography and multigated radionuclide ventriculography (RNV). Materials and methods Thirty patients with fixed perfusion defect of size greater than or equal to 25% of LV myocardium on rest g-M PS study were included. EF was calculated using three software packages: Emory Cardiac Toolbox, Myometrix, and quantitative gated single photon emission computed tomography (SPECT)/quantitative perfusion SPECT. The patients underwent RNV (gold standard) and echocardiography within a week of the g-M PS. Agreement among the EF values obtained by different methods was determined using Bland-Altman analysis. Correlation among the EF values was measured using Spearman's rank correlation. Results Thirty patients (23 male; seven female; mean age 51 years, range 32-70 years) were included prospectively. The average size of perfusion defect was 38% of the LV myocardium (range 25-56% of LV). The average ejection fraction values were 33% for Emory Cardiac Toolbox (range 11-50%), 310/0 for Myometrix (range 18-46%), and 33% for quantitative gated SPECT/quantitative perfusion SPECT (range 17-49%). The mean EF on echocardiography was 37% (range 22-60%), whereas that of RNV was 33% (range 10-50%). The data were normally distributed. There was statistically significant positive agreement between algorithm-based EF measurements to the gold standard RNV. Conclusion This study suggests that EF calculations, from g-MPS SPECT data using different software, have high agreement with the gold standard RNV even in patients with extensive perfusion defects. Nucl Med Commun 32:503-507 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:503 / 507
页数:5
相关论文
共 50 条
  • [1] Reliability of ejection fraction calculated with gated myocardial perfusion SPECT in patients with extensive perfusion defect
    Harisankar, C. N. B.
    Kamaleshwaran, K. K.
    Sarika, S.
    Parmar, M.
    Bhattacharya, A.
    Singh, B.
    Mittal, B. R.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S298 - S298
  • [2] Comparison of two software in gated myocardial perfusion single photon emission tomography, for the measurement of left ventricular volumes and ejection fraction, in patients with and without perfusion defects
    Kakhki, Vahid Reza Dabbagh
    Zakavi, Seyed Rasoul
    Sadeghi, Ramin
    [J]. HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2007, 10 (01): : 19 - 23
  • [3] Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography
    Sharir, T
    Germano, G
    Kavanagh, PB
    Lai, SH
    Cohen, I
    Lewin, HC
    Friedman, JD
    Zellweger, MJ
    Berman, DS
    [J]. CIRCULATION, 1999, 100 (10) : 1035 - 1042
  • [4] STRESS INDUCED LEFT VENTRICULAR EJECTION FRACTION AUGMENTATION DURING GATED SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY MYOCARDIAL PERFUSION IMAGING HAS NO SURVIVAL ADVANTAGE
    Mortoti, Selasie Samuel
    Opoku-Asare, Isaac
    Kassim, Thaslim
    Kokkinos, Peter
    Goheen, Erin
    Trachiotis, Gregory
    Churn, Rebecca
    Greenberg, Michael
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2011, 59 (03) : 626 - 626
  • [5] Effects of aortic tortuosity on left ventricular diastolic parameters derived from gated myocardial perfusion single photon emission computed tomography in patients with normal myocardial perfusion
    Satoshi Kurisu
    Kazuhiro Nitta
    Yoji Sumimoto
    Hiroki Ikenaga
    Ken Ishibashi
    Yukihiro Fukuda
    Yasuki Kihara
    [J]. Heart and Vessels, 2018, 33 : 651 - 656
  • [6] Aortic knob width reflects left ventricular diastolic function assessed by gated myocardial perfusion single photon emission computed tomography in patients with normal myocardial perfusion
    Kurisu, Satoshi
    Higaki, Tadanao
    Sumimoto, Yoji
    Ikenaga, Hiroki
    Watanabe, Noriaki
    Ishibashi, Ken
    Dohi, Yoshihiro
    Fukuda, Yukihiro
    Kihara, Yasuki
    [J]. ANNALS OF NUCLEAR MEDICINE, 2017, 31 (03) : 245 - 249
  • [7] Effects of aortic tortuosity on left ventricular diastolic parameters derived from gated myocardial perfusion single photon emission computed tomography in patients with normal myocardial perfusion
    Kurisu, Satoshi
    Nitta, Kazuhiro
    Sumimoto, Yoji
    Ikenaga, Hiroki
    Ishibashi, Ken
    Fukuda, Yukihiro
    Kihara, Yasuki
    [J]. HEART AND VESSELS, 2018, 33 (06) : 651 - 656
  • [8] Effect of the number of projections collected on quantitative perfusion and left ventricular ejection fraction measurements from gated myocardial perfusion single-photon emission computed tomographic images
    Germano, G
    Kavanagh, PB
    Berman, DS
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 1996, 3 (05) : 395 - 402
  • [9] Factors affecting accuracy of ventricular volume and ejection fraction measured by gated Tl-201 myocardial perfusion single photon emission computed tomography
    Pai, Moonsun
    Yang, You-Jung
    Im, Ki Chun
    Hong, Il Ki
    Yun, Sung Cheol
    Kang, Duk-Hyun
    Song, Jae-Kwan
    Moon, Dae Hyuk
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (05): : 671 - 681
  • [10] Correlation between stress and rest left ventricular ejection fraction in gated single photon emission computed tomography (SPECT) with the extent and severity of perfusion abnormalities
    Quinon, A. P.