Development of a quantum dot-based lateral flow immunoassay with high reaction consistency to total aflatoxins in botanical materials

被引:17
|
作者
Wu, Yuxiang [1 ]
Yu, Binger [2 ]
Cui, Ping [1 ]
Yu, Tao [1 ]
Shi, Guoqing [2 ]
Shen, Zhiqiang [1 ]
机构
[1] Shandong Lvdu Biotechnol Co Ltd, Binzhou 256600, Shandong, Peoples R China
[2] Univ Sci & Technol Beijing, Sch Chem & Biol Engn, Beijing 100083, Peoples R China
基金
国家重点研发计划;
关键词
Total aflatoxins; Botanical materials; Lateral flow immunoassay; Quantum dot; IMMUNOCHROMATOGRAPHIC ASSAY; QUANTITATIVE DETECTION; LIQUID-CHROMATOGRAPHY; MONOCLONAL-ANTIBODY; SENSITIVE DETECTION; RAPID DETECTION; B-1; MAIZE; M1; B2;
D O I
10.1007/s00216-020-03123-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Total aflatoxins (AFTs) are an important safety indicator for botanical materials, but at present, rapid detection technology for AFTs is seldom reported. In this study, the monoclonal antibody with similar reactivity to total aflatoxins was produced, and the quantum dot-based lateral flow immunoassay (QD-LFIA) coupled with a portable device was developed to rapidly determine AFT residues in botanical materials. The half maximal inhibitory concentrations (IC50) of the QD-LFIA for AFB1, AFB2, AFG1, AFG2, AFM1, and AFM2 were 10.57, 12.64, 11.34, 12.67, 10.13, and 12.75 mu g kg(-1), respectively, which show high reaction consistency to total aflatoxins. For different botanical materials, the sample was simply extracted with methanol-water and diluted with PBS, and the sample solution was directly loaded onto the QD-LFIA strip for determination. To overcome interference from the matrix effects, specific standard curves were established for each kind of botanical material. The detection limit of AFTs in 6 different botanical materials was 0.95 similar to 2.03 mu g kg(-1) with a linear range of 2 similar to 120 mu g kg(-1). The spiked recoveries of AFTs in botanical materials of different species and localities of growth were 75 similar to 105% with a coefficient of variation below 15%. The test results of the actual samples are consistent with the Chinese national standard test method. This study provides an easy-to-use method to rapidly determine AFTs in different botanical materials.
引用
收藏
页码:1629 / 1637
页数:9
相关论文
共 44 条
  • [1] Development of a quantum dot–based lateral flow immunoassay with high reaction consistency to total aflatoxins in botanical materials
    Yuxiang Wu
    Binger Yu
    Ping Cui
    Tao Yu
    Guoqing Shi
    Zhiqiang Shen
    Analytical and Bioanalytical Chemistry, 2021, 413 : 1629 - 1637
  • [2] Quantum dot-based lateral flow immunoassay for detection of chloramphenicol in milk
    Anna N. Berlina
    Nadezhda A. Taranova
    Anatoly V. Zherdev
    Yuri Y. Vengerov
    Boris B. Dzantiev
    Analytical and Bioanalytical Chemistry, 2013, 405 : 4997 - 5000
  • [3] Quantum dot-based lateral flow immunoassay for detection of chloramphenicol in milk
    Berlina, Anna N.
    Taranova, Nadezhda A.
    Zherdev, Anatoly V.
    Vengerov, Yuri Y.
    Dzantiev, Boris B.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (14) : 4997 - 5000
  • [4] Rapid lateral-flow immunoassay for the quantum dot-based detection of puerarin
    Qu, Huihua
    Zhang, Yue
    Qu, Baoping
    Kong, Hui
    Qin, Gaofeng
    Liu, Shuchen
    Cheng, Jinjun
    Wang, Qingguo
    Zhao, Yan
    BIOSENSORS & BIOELECTRONICS, 2016, 81 : 358 - 362
  • [5] A New Quantum Dot-Based Lateral Flow Immunoassay for the Rapid Detection of Influenza Viruses
    Kim, Soo-Kyung
    Sung, Heungsup
    Hwang, Sang-Hyun
    Kim, Mi-Na
    BIOCHIP JOURNAL, 2022, 16 (02) : 175 - 182
  • [6] A New Quantum Dot-Based Lateral Flow Immunoassay for the Rapid Detection of Influenza Viruses
    Soo-Kyung Kim
    Heungsup Sung
    Sang-Hyun Hwang
    Mi-Na Kim
    BioChip Journal, 2022, 16 : 175 - 182
  • [7] Development of Quantum Dot-Based Lateral Flow Immunoassay System for Rapid Quantitative Detection of Human Chorionic Gonadotropin
    Yang Qiu-Hua
    Wang Xin
    Yang Jiu-Min
    Li Xue
    Song Tao
    Gong Xiao-Qun
    Zhang Bing-Bo
    Chang Jin
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2014, 41 (05) : 497 - 507
  • [8] Development of carbon quantum dot-based lateral flow immunoassay for sensitive detection of aflatoxin M1 in milk
    Singh, Harpreet
    Singh, Shalini
    Bhardwaj, Sanjeev K.
    Kaur, Gurjeet
    Khatri, Madhu
    Deep, Akash
    Bhardwaj, Neha
    FOOD CHEMISTRY, 2022, 393
  • [9] Development of a high sensitivity quantum dot-based fluorescent quenching lateral flow assay for the detection of zearalenone
    Yuan Chen
    Qiangqiang Fu
    Jun Xie
    Hong Wang
    Yong Tang
    Analytical and Bioanalytical Chemistry, 2019, 411 : 2169 - 2175
  • [10] Development of a high sensitivity quantum dot-based fluorescent quenching lateral flow assay for the detection of zearalenone
    Chen, Yuan
    Fu, Qiangqiang
    Xie, Jun
    Wang, Hong
    Tang, Yong
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (10) : 2169 - 2175