Development of a quantum dot-based lateral flow immunoassay with high reaction consistency to total aflatoxins in botanical materials

被引:17
|
作者
Wu, Yuxiang [1 ]
Yu, Binger [2 ]
Cui, Ping [1 ]
Yu, Tao [1 ]
Shi, Guoqing [2 ]
Shen, Zhiqiang [1 ]
机构
[1] Shandong Lvdu Biotechnol Co Ltd, Binzhou 256600, Shandong, Peoples R China
[2] Univ Sci & Technol Beijing, Sch Chem & Biol Engn, Beijing 100083, Peoples R China
基金
国家重点研发计划;
关键词
Total aflatoxins; Botanical materials; Lateral flow immunoassay; Quantum dot; IMMUNOCHROMATOGRAPHIC ASSAY; QUANTITATIVE DETECTION; LIQUID-CHROMATOGRAPHY; MONOCLONAL-ANTIBODY; SENSITIVE DETECTION; RAPID DETECTION; B-1; MAIZE; M1; B2;
D O I
10.1007/s00216-020-03123-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Total aflatoxins (AFTs) are an important safety indicator for botanical materials, but at present, rapid detection technology for AFTs is seldom reported. In this study, the monoclonal antibody with similar reactivity to total aflatoxins was produced, and the quantum dot-based lateral flow immunoassay (QD-LFIA) coupled with a portable device was developed to rapidly determine AFT residues in botanical materials. The half maximal inhibitory concentrations (IC50) of the QD-LFIA for AFB1, AFB2, AFG1, AFG2, AFM1, and AFM2 were 10.57, 12.64, 11.34, 12.67, 10.13, and 12.75 mu g kg(-1), respectively, which show high reaction consistency to total aflatoxins. For different botanical materials, the sample was simply extracted with methanol-water and diluted with PBS, and the sample solution was directly loaded onto the QD-LFIA strip for determination. To overcome interference from the matrix effects, specific standard curves were established for each kind of botanical material. The detection limit of AFTs in 6 different botanical materials was 0.95 similar to 2.03 mu g kg(-1) with a linear range of 2 similar to 120 mu g kg(-1). The spiked recoveries of AFTs in botanical materials of different species and localities of growth were 75 similar to 105% with a coefficient of variation below 15%. The test results of the actual samples are consistent with the Chinese national standard test method. This study provides an easy-to-use method to rapidly determine AFTs in different botanical materials.
引用
收藏
页码:1629 / 1637
页数:9
相关论文
共 44 条
  • [41] Development of CdTe/ZnSe Core/Shell Quantum Dots-based Lateral-Flow Immunoassay for Rapid Detection of Clenbuterol
    Hu Hua-Jun
    Fu Tao
    Zhang Ming-Zhou
    Hong Zhi
    Chen Zhong-Lun
    Liu Jun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (12) : 1727 - 1731
  • [42] Fluorescent lateral flow immunoassay for highly sensitive detection of eight anticoagulant rodenticides based on cadmium-free quantum dot-encapsulated nanospheres
    Li, Hongfang
    Dong, Baolei
    Dou, Leina
    Yu, Wenbo
    Yu, Xuezhi
    Wen, Kai
    Ke, Yuebin
    Shen, Jianzhong
    Wang, Zhanhui
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 324
  • [43] Sensitive and Simultaneous Detection of SARS-CoV-2-Specific IgM/IgG Using Lateral Flow Immunoassay Based on Dual-Mode Quantum Dot Nanobeads
    Wang, Chongwen
    Yang, Xingsheng
    Gu, Bing
    Liu, Haifeng
    Zhou, Zihui
    Shi, Luoluo
    Cheng, Xiaodan
    Wang, Shengqi
    ANALYTICAL CHEMISTRY, 2020, 92 (23) : 15542 - 15549
  • [44] Quantum Dot Nanobeads-Labelled Lateral Flow Immunoassay Strip for Rapid and Sensitive Detection of Salmonella Typhimurium Based on Strand Displacement Loop-Mediated Isothermal Amplification
    Shang, Yuting
    Cai, Shuzhen
    Ye, Qinghua
    Wu, Qingping
    Shao, Yanna
    Qu, Xiaoying
    Xiang, Xinran
    Zhou, Baoqing
    Ding, Yu
    Chen, Moutong
    Xue, Liang
    Zhu, Honghui
    Zhang, Jumei
    ENGINEERING, 2022, 19 : 62 - 70