Development of a quantum dot-based lateral flow immunoassay with high reaction consistency to total aflatoxins in botanical materials

被引:17
|
作者
Wu, Yuxiang [1 ]
Yu, Binger [2 ]
Cui, Ping [1 ]
Yu, Tao [1 ]
Shi, Guoqing [2 ]
Shen, Zhiqiang [1 ]
机构
[1] Shandong Lvdu Biotechnol Co Ltd, Binzhou 256600, Shandong, Peoples R China
[2] Univ Sci & Technol Beijing, Sch Chem & Biol Engn, Beijing 100083, Peoples R China
基金
国家重点研发计划;
关键词
Total aflatoxins; Botanical materials; Lateral flow immunoassay; Quantum dot; IMMUNOCHROMATOGRAPHIC ASSAY; QUANTITATIVE DETECTION; LIQUID-CHROMATOGRAPHY; MONOCLONAL-ANTIBODY; SENSITIVE DETECTION; RAPID DETECTION; B-1; MAIZE; M1; B2;
D O I
10.1007/s00216-020-03123-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Total aflatoxins (AFTs) are an important safety indicator for botanical materials, but at present, rapid detection technology for AFTs is seldom reported. In this study, the monoclonal antibody with similar reactivity to total aflatoxins was produced, and the quantum dot-based lateral flow immunoassay (QD-LFIA) coupled with a portable device was developed to rapidly determine AFT residues in botanical materials. The half maximal inhibitory concentrations (IC50) of the QD-LFIA for AFB1, AFB2, AFG1, AFG2, AFM1, and AFM2 were 10.57, 12.64, 11.34, 12.67, 10.13, and 12.75 mu g kg(-1), respectively, which show high reaction consistency to total aflatoxins. For different botanical materials, the sample was simply extracted with methanol-water and diluted with PBS, and the sample solution was directly loaded onto the QD-LFIA strip for determination. To overcome interference from the matrix effects, specific standard curves were established for each kind of botanical material. The detection limit of AFTs in 6 different botanical materials was 0.95 similar to 2.03 mu g kg(-1) with a linear range of 2 similar to 120 mu g kg(-1). The spiked recoveries of AFTs in botanical materials of different species and localities of growth were 75 similar to 105% with a coefficient of variation below 15%. The test results of the actual samples are consistent with the Chinese national standard test method. This study provides an easy-to-use method to rapidly determine AFTs in different botanical materials.
引用
收藏
页码:1629 / 1637
页数:9
相关论文
共 44 条
  • [31] Quantum-dot-based sandwich lateral flow immunoassay for the rapid detection of shrimp major allergen tropomyosin
    Li, Ranran
    Zhang, Yaoyang
    Zhao, Jinlong
    Wang, Yaqing
    Wang, Hao
    Zhang, Ziye
    Lin, Hong
    Li, Zhenxing
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2022, 114
  • [32] Recent Advances in Quantum Dot-Based Lateral Flow Immunoassays for the Rapid, Point-of-Care Diagnosis of COVID-19
    Mousavi, Seyyed Mojtaba
    Kalashgrani, Masoomeh Yari
    Gholami, Ahmad
    Omidifar, Navid
    Binazadeh, Mojtaba
    Chiang, Wei-Hung
    BIOSENSORS-BASEL, 2023, 13 (08):
  • [33] Development of a rapid and sensitive quantum dot nanobead-based double-antigen sandwich lateral flow immunoassay and its clinical performance for the detection of SARS-CoV-2 total antibodies
    Zhou, Yaofeng
    Chen, Yuan
    Liu, Wenjuan
    Fang, Hao
    Li, Xiangmin
    Hou, Li
    Liu, Yuanjie
    Lai, Weihua
    Huang, Xiaolin
    Xiong, Yonghua
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 343
  • [34] Development of a smartphone-based quantum dot lateral flow immunoassay strip for ultrasensitive detection of anti-SARS-CoV-2 IgG and neutralizing antibodies
    Li, Jinfeng
    Liu, Bochao
    Tang, Xi
    Wu, Ze
    Lu, Jinhui
    Liang, Chaolan
    Hou, Shuiping
    Zhang, Ling
    Li, Tingting
    Zhao, Wei
    Fu, Yongshui
    Ke, Yuebin
    Li, Chengyao
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2022, 121 : 58 - 65
  • [35] Ultrasensitive point-of-care multiplex diagnosis for influenza virus based robust quantum dot microsphere-lateral flow immunoassay
    Zhang, Yuning
    Lv, Yanbing
    Chen, Xinxin
    Ye, Yingli
    Yu, Shenping
    Li, Ning
    Yao, Hongtao
    Wang, Zhizeng
    Feng, Qitong
    Wu, Ruili
    Li, Lin Song
    BIOSENSORS & BIOELECTRONICS, 2025, 273
  • [36] A fast and sensitive immunoassay of avian influenza virus based on label-free quantum dot probe and lateral flow test strip
    Li, Xuepu
    Lu, Donglian
    Sheng, Zonghai
    Chen, Kun
    Guo, Xuebo
    Jin, Meilin
    Han, Heyou
    TALANTA, 2012, 100 : 1 - 6
  • [37] Development of nanobody-based flow-through dot ELISA and lateral-flow immunoassay for rapid detection of 3-phenoxybenzoic acid†
    Zhang, Can
    Wu, Xiaoxiao
    Li, Dongyang
    Hu, Jinnuo
    Wan, Debin
    Zhang, Zhen
    Hammock, Bruce D.
    ANALYTICAL METHODS, 2021, 13 (14) : 1757 - 1765
  • [38] Simultaneous detection of OTA and AFB1 in cereals based on bispecific monoclonal antibody using quantum dot nanobead lateral flow immunoassay
    Wu, Mengyun
    Xia, Jun
    Liu, Tingting
    Xue, Guangjian
    Fang, Xuechen
    Lai, Weihua
    Peng, Juan
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2023, 34 (01) : 48 - 66
  • [39] Using a quantum dot bead-based lateral flow immunoassay to broadly detect the adulteration of PDE-5 inhibitors in functional foods
    Song, Mingshu
    Wu, Qin
    Liu, Beibei
    Li, Pan
    Jiang, Lan
    Wang, Yulong
    Dong, Sa
    Xiong, Yonghua
    Hammock, Bruce D.
    Zhang, Cunzheng
    ANALYTICAL METHODS, 2022, 14 (26) : 2586 - 2595
  • [40] Dual-Fluorescent Quantum Dot Nanobead-Based Lateral Flow Immunoassay for Simultaneous Detection of C-Reactive Protein and Procalcitonin
    Tang, Xinyue
    Xia, Wenwen
    Han, Huanxing
    Wang, Yucheng
    Wang, Bolong
    Gao, Shouhong
    Zhang, Pengfei
    ACS APPLIED BIO MATERIALS, 2024, 7 (11): : 7659 - 7665