A fast and sensitive immunoassay of avian influenza virus based on label-free quantum dot probe and lateral flow test strip

被引:82
|
作者
Li, Xuepu [1 ]
Lu, Donglian [1 ]
Sheng, Zonghai [1 ]
Chen, Kun [1 ]
Guo, Xuebo [2 ]
Jin, Meilin [2 ]
Han, Heyou [1 ]
机构
[1] Huazhong Normal Univ, Coll Sci, State Key Lab Agr Microbiol, Wuhan 430070, Peoples R China
[2] Huazhong Agr Univ, State Key Lab Agr Microbiol, Unit Anim Infect Dis, Wuhan 430070, Peoples R China
基金
中国国家自然科学基金;
关键词
Quantum dots; Fluorescence immunoassay; Signal amplification; Avian influenza virus; Lateral flow test strip; LINKED-IMMUNOSORBENT-ASSAY; ELECTROCHEMICAL IMMUNOSENSOR; IMMUNOCHROMATOGRAPHIC STRIP; RAPID DETECTION; H5; ELISA; ANTIBODIES; BIOSENSOR; DIAGNOSIS; H7;
D O I
10.1016/j.talanta.2012.08.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel fluorescence immunoassay method for fast and ultrasensitive detection of avian influenza virus (AIV) was developed. The immunoassay method which integrated lateral flow test strip technique with fluorescence immunoassay used the label-free and high luminescent quantum dots (QDs) as signal output. By the sandwich immunoreaction performed on lateral flow test strip, the gold nanoparticle (NP) labels were captured in the test zone and further dissolved to release a large number of gold ions as a signal transduction bridge that was detected by the QDs-based fluorescence quenching method. Under the optimal conditions, the relative fluorescence intensity of QDs was linear over the range of 0.27-12 ng mL(-1) AIV, and the limit of detection was estimated to be 0.09 ng mL(-1) which was 100-fold greater than enzyme-linked immunosorbent assay (ELISA). The sensitive and specific response was also coupled with high reproducibility in the proposed method. A series of six parallel measurements produced reproducible fluorescent signals with a relative standard deviation of 4.7%. The proposed method can be used to directly detect clinical sample without any pretreatment, and showed high efficiency (90.0%), sensitivity (100.0%) and specificity (88.2%) compared with virus isolation (gold method). The new method shows great promise for rapid, sensitive, and quantitative detection of AIV in-field or point-of-care diagnosis. Crown Copyright (C) 2012 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [1] A fast and simple label-free immunoassay based on a smartphone
    Giavazzi, Fabio
    Salina, Matteo
    Ceccarello, Erica
    Ilacqua, Andrea
    Damin, Francesco
    Sola, Laura
    Chiari, Marcella
    Chini, Bice
    Cerbino, Roberto
    Bellini, Tommaso
    Buscaglia, Marco
    BIOSENSORS & BIOELECTRONICS, 2014, 58 : 395 - 402
  • [2] A one-piece lateral flow impedimetric test strip for label-free clenbuterol detection
    Shi, ZhuanZhuan
    Tian, YunLi
    Wu, XiaoShuai
    Li, ChangMing
    Yu, Ling
    ANALYTICAL METHODS, 2015, 7 (12) : 4957 - 4964
  • [3] A sensitive lateral flow test strip based on silica nanoparticle/CdTe quantum dot composite reporter probes
    Bai, Yalong
    Tian, Chunyuan
    Wei, Xinlin
    Wang, Yuanfeng
    Wang, Dapeng
    Shi, Xianming
    RSC ADVANCES, 2012, 2 (05): : 1778 - 1781
  • [4] Label-free microcantilever-based immunosensors for highly sensitive determination of avian influenza virus H9
    Dan Xu
    Lin Liu
    Jun Guan
    Jianyun Xu
    Ting Wang
    Aijian Qin
    Xiaoya Hu
    Chengyin Wang
    Microchimica Acta, 2014, 181 : 403 - 410
  • [5] Label-free microcantilever-based immunosensors for highly sensitive determination of avian influenza virus H9
    Xu, Dan
    Liu, Lin
    Guan, Jun
    Xu, Jianyun
    Wang, Ting
    Qin, Aijian
    Hu, Xiaoya
    Wang, Chengyin
    MICROCHIMICA ACTA, 2014, 181 (3-4) : 403 - 410
  • [6] VS2 quantum dot label-free fluorescent probe for sensitive and selective detection of ALP
    Ma, Xiaohan
    Du, Cuicui
    Shang, Mengxiang
    Song, Wenbo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (05) : 1417 - 1426
  • [7] VS2 quantum dot label-free fluorescent probe for sensitive and selective detection of ALP
    Xiaohan Ma
    Cuicui Du
    Mengxiang Shang
    Wenbo Song
    Analytical and Bioanalytical Chemistry, 2018, 410 : 1417 - 1426
  • [8] A General Strategy for Label-Free Sensitive DNA Detection Based on Quantum Dot Doping
    He, Xuewen
    Ma, Nan
    ANALYTICAL CHEMISTRY, 2014, 86 (07) : 3676 - 3681
  • [9] A New Quantum Dot-Based Lateral Flow Immunoassay for the Rapid Detection of Influenza Viruses
    Soo-Kyung Kim
    Heungsup Sung
    Sang-Hyun Hwang
    Mi-Na Kim
    BioChip Journal, 2022, 16 : 175 - 182
  • [10] A New Quantum Dot-Based Lateral Flow Immunoassay for the Rapid Detection of Influenza Viruses
    Kim, Soo-Kyung
    Sung, Heungsup
    Hwang, Sang-Hyun
    Kim, Mi-Na
    BIOCHIP JOURNAL, 2022, 16 (02) : 175 - 182