A fast and sensitive immunoassay of avian influenza virus based on label-free quantum dot probe and lateral flow test strip

被引:82
|
作者
Li, Xuepu [1 ]
Lu, Donglian [1 ]
Sheng, Zonghai [1 ]
Chen, Kun [1 ]
Guo, Xuebo [2 ]
Jin, Meilin [2 ]
Han, Heyou [1 ]
机构
[1] Huazhong Normal Univ, Coll Sci, State Key Lab Agr Microbiol, Wuhan 430070, Peoples R China
[2] Huazhong Agr Univ, State Key Lab Agr Microbiol, Unit Anim Infect Dis, Wuhan 430070, Peoples R China
基金
中国国家自然科学基金;
关键词
Quantum dots; Fluorescence immunoassay; Signal amplification; Avian influenza virus; Lateral flow test strip; LINKED-IMMUNOSORBENT-ASSAY; ELECTROCHEMICAL IMMUNOSENSOR; IMMUNOCHROMATOGRAPHIC STRIP; RAPID DETECTION; H5; ELISA; ANTIBODIES; BIOSENSOR; DIAGNOSIS; H7;
D O I
10.1016/j.talanta.2012.08.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel fluorescence immunoassay method for fast and ultrasensitive detection of avian influenza virus (AIV) was developed. The immunoassay method which integrated lateral flow test strip technique with fluorescence immunoassay used the label-free and high luminescent quantum dots (QDs) as signal output. By the sandwich immunoreaction performed on lateral flow test strip, the gold nanoparticle (NP) labels were captured in the test zone and further dissolved to release a large number of gold ions as a signal transduction bridge that was detected by the QDs-based fluorescence quenching method. Under the optimal conditions, the relative fluorescence intensity of QDs was linear over the range of 0.27-12 ng mL(-1) AIV, and the limit of detection was estimated to be 0.09 ng mL(-1) which was 100-fold greater than enzyme-linked immunosorbent assay (ELISA). The sensitive and specific response was also coupled with high reproducibility in the proposed method. A series of six parallel measurements produced reproducible fluorescent signals with a relative standard deviation of 4.7%. The proposed method can be used to directly detect clinical sample without any pretreatment, and showed high efficiency (90.0%), sensitivity (100.0%) and specificity (88.2%) compared with virus isolation (gold method). The new method shows great promise for rapid, sensitive, and quantitative detection of AIV in-field or point-of-care diagnosis. Crown Copyright (C) 2012 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [21] Quantum dot-based lateral flow immunoassay for detection of chloramphenicol in milk
    Berlina, Anna N.
    Taranova, Nadezhda A.
    Zherdev, Anatoly V.
    Vengerov, Yuri Y.
    Dzantiev, Boris B.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (14) : 4997 - 5000
  • [22] Quantum Dot-Based Lateral Flow Test Strips for Highly Sensitive Detection of the Tetanus Antibody
    Wang, Junyan
    Meng, Hong-Min
    Chen, Juan
    Liu, Juanzu
    Zhang, Lin
    Qu, Lingbo
    Li, Zhaohui
    Lin, Yuehe
    ACS OMEGA, 2019, 4 (04): : 6789 - 6795
  • [23] Detection of avian influenza virus utilizing fluorescent nanodiamonds for lateral flow immunoassay enhanced by magnetic modulation
    Angela, Stefanny
    Hsiao, Wesley Wei-Wen
    Fadhilah, Gianna
    Le, Trong-Nghia
    Chiang, Wei-Hung
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2025, 169
  • [24] Carbon nanotag based visual detection of influenza A virus by a lateral flow immunoassay
    Natpapas Wiriyachaiporn
    Hathainan Sirikett
    Weerakanya Maneeprakorn
    Tararaj Dharakul
    Microchimica Acta, 2017, 184 : 1827 - 1835
  • [25] Carbon nanotag based visual detection of influenza A virus by a lateral flow immunoassay
    Wiriyachaiporn, Natpapas
    Sirikett, Hathainan
    Maneeprakorn, Weerakanya
    Dharakul, Tararaj
    MICROCHIMICA ACTA, 2017, 184 (06) : 1827 - 1835
  • [26] Biomimetic Nanopillar-Based Biosensor for Label-Free Detection of Influenza A Virus
    Wang Sik Lee
    Junhyoung Ahn
    Sanghee Jung
    Jaejong Lee
    Taejoon Kang
    Jinyoung Jeong
    BioChip Journal, 2021, 15 : 260 - 267
  • [27] Green fluorescent carbon quantum dots as a label-free probe for rapid and sensitive detection of hematin
    Liang, Jia Yu
    Han, Lei
    Liu, Shi Gang
    Ju, Yan Jun
    Gao, Xin
    Li, Nian Bing
    Luo, Hong Qun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 212 : 167 - 172
  • [28] Biomimetic Nanopillar-Based Biosensor for Label-Free Detection of Influenza A Virus
    Lee, Wang Sik
    Ahn, Junhyoung
    Jung, Sanghee
    Lee, Jaejong
    Kang, Taejoon
    Jeong, Jinyoung
    BIOCHIP JOURNAL, 2021, 15 (03) : 260 - 267
  • [29] Label-free silicon quantum dots as fluorescent probe for selective and sensitive detection of copper ions
    Zhao, Jiangna
    Deng, Jianhui
    Yi, Yinhui
    Li, Haitai
    Zhang, Youyu
    Yao, Shouzhuo
    TALANTA, 2014, 125 : 372 - 377
  • [30] Fluorescent lateral flow immunoassay for highly sensitive detection of eight anticoagulant rodenticides based on cadmium-free quantum dot-encapsulated nanospheres
    Li, Hongfang
    Dong, Baolei
    Dou, Leina
    Yu, Wenbo
    Yu, Xuezhi
    Wen, Kai
    Ke, Yuebin
    Shen, Jianzhong
    Wang, Zhanhui
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 324