Rapid lateral-flow immunoassay for the quantum dot-based detection of puerarin

被引:62
|
作者
Qu, Huihua [1 ]
Zhang, Yue [2 ]
Qu, Baoping [3 ]
Kong, Hui [3 ]
Qin, Gaofeng [3 ]
Liu, Shuchen [3 ]
Cheng, Jinjun [3 ]
Wang, Qingguo [3 ]
Zhao, Yan [3 ]
机构
[1] Beijing Univ Chinese Med, Ctr Sci Expt, Beijing, Peoples R China
[2] Beijing Univ Chinese Med, Sch Chinese Mat Med, Beijing, Peoples R China
[3] Beijing Univ Chinese Med, Sch Basic Med Sci, Beijing, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Lateral flow immunoassay; Monoclonal antibody; Puerarin; Quantum dot; STEP IMMUNOCHROMATOGRAPHIC ASSAY; C-REACTIVE PROTEIN; SENSITIVE DETECTION; TEST STRIP; ANTIBODY; CHLORPYRIFOS; BIOMARKER; EXPOSURE; VIRUS;
D O I
10.1016/j.bios.2016.03.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this study, a rapid (within 10 min) quantitative lateral-flow immunoassay using a quantum dots (QDs)-antibody probe was developed for the analysis of puerarin (PUE) in water and biological samples. The competitive immunoassay was based on anti-PUE monoclonal antibody conjugated with QDs (detection reagent). Secondary antibody was immobilized on one end of a nitrocellulose membrane (control line) and PUE-bovine serum albumin conjugate was immobilized on the other end (test line). In the quantitative experiment, the detection results were scanned using a membrane strip reader and a detection curve (regression equation: y= -0.11 ln(x)+ 0.979, R-2 = 0.9816) representing the averages of the scanned data was obtained. This curve was linear from 1 to 10 mu g/mL. The IC50 value was 75.58 ng/mL and the qualitative detection limit of PUE was 5.8 ng/mL. The recovery of PUE added to phosphate-buffered saline and biological samples was in the range of 97.38-116.56%. To our knowledge, this is the first report of the quantitative detection of a natural product by QDs-based immunochromatography, which represents a powerful tool for rapidly screening PUE in plant materials and other biological samples. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:358 / 362
页数:5
相关论文
共 50 条
  • [1] Quantum dot-based lateral-flow immunoassay for rapid detection of rhein using specific egg yolk antibodies
    Zhang, Yue
    Kong, Hui
    Liu, Xiaoman
    Cheng, Jinjun
    Zhang, Meiling
    Wang, Yongzhi
    Lu, Fang
    Qu, Huihua
    Zhao, Yan
    [J]. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2018, 46 (08) : 1685 - 1693
  • [2] A New Quantum Dot-Based Lateral Flow Immunoassay for the Rapid Detection of Influenza Viruses
    Soo-Kyung Kim
    Heungsup Sung
    Sang-Hyun Hwang
    Mi-Na Kim
    [J]. BioChip Journal, 2022, 16 : 175 - 182
  • [3] A New Quantum Dot-Based Lateral Flow Immunoassay for the Rapid Detection of Influenza Viruses
    Kim, Soo-Kyung
    Sung, Heungsup
    Hwang, Sang-Hyun
    Kim, Mi-Na
    [J]. BIOCHIP JOURNAL, 2022, 16 (02) : 175 - 182
  • [4] Quantum dot-based lateral flow immunoassay for detection of chloramphenicol in milk
    Anna N. Berlina
    Nadezhda A. Taranova
    Anatoly V. Zherdev
    Yuri Y. Vengerov
    Boris B. Dzantiev
    [J]. Analytical and Bioanalytical Chemistry, 2013, 405 : 4997 - 5000
  • [5] Quantum dot-based lateral flow immunoassay for detection of chloramphenicol in milk
    Berlina, Anna N.
    Taranova, Nadezhda A.
    Zherdev, Anatoly V.
    Vengerov, Yuri Y.
    Dzantiev, Boris B.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (14) : 4997 - 5000
  • [6] Development of Quantum Dot-Based Lateral Flow Immunoassay System for Rapid Quantitative Detection of Human Chorionic Gonadotropin
    Yang Qiu-Hua
    Wang Xin
    Yang Jiu-Min
    Li Xue
    Song Tao
    Gong Xiao-Qun
    Zhang Bing-Bo
    Chang Jin
    [J]. PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2014, 41 (05) : 497 - 507
  • [7] Development of quantum dot-based fluorescence lateral flow immunoassay strip for rapid and quantitative detection of serum interleukin-6
    Tang, Jinsong
    Wu, Lili
    Lin, Jingtao
    Zhang, Erying
    Luo, Yong
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (05)
  • [8] Development of a quantum dot-based lateral flow immunoassay strip for rapid and sensitive detection of SARS-CoV-2 neutralizing antibodies
    Wang, Xirong
    Shao, Shulin
    Ye, Huan
    Li, Sen
    Gu, Bing
    Tang, Bo
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01):
  • [9] Development of a quantum dot-based lateral flow immunoassay strip for rapid and sensitive detection of SARS-CoV-2 neutralizing antibodies
    Xirong Wang
    Shulin Shao
    Huan Ye
    Sen Li
    Bing Gu
    Bo Tang
    [J]. Scientific Reports, 13 (1)
  • [10] Development of carbon quantum dot-based lateral flow immunoassay for sensitive detection of aflatoxin M1 in milk
    Singh, Harpreet
    Singh, Shalini
    Bhardwaj, Sanjeev K.
    Kaur, Gurjeet
    Khatri, Madhu
    Deep, Akash
    Bhardwaj, Neha
    [J]. FOOD CHEMISTRY, 2022, 393