Design and test results of different aluminum coating layers on the sCMOS sensors for soft X-ray detection

被引:4
|
作者
Wang, W. X. [1 ]
Ling, Z. X. [1 ,2 ]
Zhang, C. [1 ,2 ]
Yuan, W. M. [1 ,2 ]
Zhang, S. N. [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Key Lab Space Astron & Technol, Natl Astron Observ, Beijing 100101, Peoples R China
[2] Univ Chinese Acad Sci, Sch Astron & Space Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Imaging spectroscopy; Solid state detectors; X-ray detectors; PERFORMANCE;
D O I
10.1088/1748-0221/17/12/P12016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In recent years, tremendous progress has been made on complementary metal-oxide -semiconductor (CMOS) sensors for applications as X-ray detectors. To shield the visible light in X-ray detection, a blocking filter of aluminum is commonly employed. We designed three types of aluminum coating layers, which are deposited directly on the surface of back-illuminated sCMOS sensors during fabrication. A commercial 2k x 2k sCMOS sensor is used to realize these designs. In this work, we report their performance by comparison with that of an uncoated sCMOS sensor. The optical transmissions at 660 nm and 850 nm are measured, and the results show that the optical transmission reaches a level of about 10-9 for the 200 nm aluminum layer and about 10-4 for the 100 nm aluminum layer. Light leakage is found around the four sides of the sensor. The readout noise, fixed-pattern noise and energy resolution of these Al-coated sCMOS sensors do not show significant changes. The dark currents of these Al-coated sCMOS sensors show a noticeable increase compared with that of the uncoated sCMOS sensor at room temperatures, while no significant difference is found when the sCMOS sensors are cooled down to about -15 degrees C. The aluminum coatings show no visible crack after the thermal cycle and aging tests. Based on these results, an aluminum coating of a larger area on larger sCMOS sensors is proposed for future work.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Design of a broadband soft x-ray polarimeter
    Marshall, Herman L.
    Guenther, H. Moritz
    Heilmann, Ralf K.
    Schulz, Norbert S.
    Egan, Mark
    Hellickson, Tim
    Heine, Sarah N. T.
    Windt, David L.
    Gullikson, Eric M.
    Ramsey, Brian
    Tagliaferri, Gianpiero
    Pareschi, Giovanni
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2018, 4 (01)
  • [22] Magnetic sensors for x-ray and gamma-ray detection
    Enss, C
    LOW TEMPERATURE DETECTORS, 2002, 605 : 5 - 10
  • [23] HIGH-RESOLUTION SUPERCONDUCTING X-RAY SPECTROMETERS WITH ALUMINUM TRAPPING LAYERS OF DIFFERENT THICKNESSES
    MEARS, CA
    LABOV, SE
    HILLER, LH
    FRANK, M
    NETEL, H
    AZGUI, F
    BARFKNECHT, AT
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1995, 5 (02) : 3069 - 3072
  • [24] Design, Fabrication and Test of a Soft X-Ray Even-Order Transmission Grating
    Ma Jie
    Xie Chang-Qing
    Liu Ming
    Chen Bao-Qin
    Ye Tian-Chun
    CHINESE PHYSICS LETTERS, 2009, 26 (09)
  • [25] Simulation of recombination pumped aluminum soft X-ray laser
    Zhu, CJ
    Ozaki, T
    Orimo, S
    Kanai, T
    Liang, JQ
    Kuroda, H
    Aoki, T
    PROGRESS IN CRYSTAL GROWTH AND CHARACTERIZATION OF MATERIALS, 1996, 33 (1-3): : 285 - 288
  • [26] DESIGN AND PRIMARY RESULTS OF X-RAY HEATING ALUMINUM FOIL EXPERIMENTS AT PTS FACILITY
    Li, Jing
    Huang, Xianbin
    Cai, Hongchun
    Duan, Shuchao
    Zhang, Siqun
    Ren, Xiaodong
    Wang, Kunlun
    Dan, Jiakun
    Zhou, Shaotong
    Xu, Qiang
    Ji, Ce
    Feng, Shuping
    Wang, Meng
    Xie, Weiping
    Deng, Jianjun
    2015 42ND IEEE INTERNATIONAL CONFERENCE ON PLASMA SCIENCES (ICOPS), 2015,
  • [27] Interferometric soft x-ray index measurements: Progress of system design and recent results
    Joyeux, D
    Polack, F
    Phalippou, D
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 641 - 646
  • [28] A pixel design for X-ray imaging with CdTe sensors
    Lambropoulos, C. P.
    Zervakis, E. G.
    Loukas, D.
    PHYSICA STATUS SOLIDI C - CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 5, NO 12 2008, 2008, 5 (12): : 3862 - +
  • [29] Performance of a focal plane detector for soft X-ray imaging spectroscopy based on back-illuminated sCMOS
    Chen, Can
    Wang, Yusa
    Xu, Yupeng
    Zhao, Zijian
    Qiu, Hongyun
    Hou, Dongjie
    Yang, Xiongtao
    Ma, Jia
    Chen, Yong
    Zhao, Yang
    Liu, Hua
    Zhao, Xiaofan
    Zhu, Yuxuan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1030
  • [30] Calibration of soft X-ray detection with synchrotron radiation
    Sun, KX
    Yi, RQ
    Jiang, SE
    Yang, JM
    Huang, TX
    Cui, YL
    Yang, GH
    Ding, YK
    Liu, SY
    Zhang, BH
    Wang, HB
    Wen, SH
    Zheng, ZJ
    Jiang, WM
    Zhao, YK
    Cui, MQ
    Zhu, PP
    Zhao, YD
    Li, G
    Zhu, J
    Zheng, L
    Tang, ES
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (02): : 205 - 209