Performance of a focal plane detector for soft X-ray imaging spectroscopy based on back-illuminated sCMOS

被引:6
|
作者
Chen, Can [1 ,2 ]
Wang, Yusa [1 ]
Xu, Yupeng [1 ,2 ]
Zhao, Zijian [1 ]
Qiu, Hongyun [3 ]
Hou, Dongjie [1 ]
Yang, Xiongtao [1 ]
Ma, Jia [1 ]
Chen, Yong [1 ]
Zhao, Yang [3 ]
Liu, Hua [3 ]
Zhao, Xiaofan [1 ]
Zhu, Yuxuan [1 ,4 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Key Lab Particle Astrophys, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, Chinese Acad Sci, Beijing 100049, Peoples R China
[3] QHYCCD Ltd, Beijing 100084, Peoples R China
[4] Jilin Univ, Coll Phys, Changchun 130012, Peoples R China
关键词
Back-illuminated CMOS sensor; X-ray detector; X-ray optics; Alignment; Imaging spectroscopy; eXTP;
D O I
10.1016/j.nima.2022.166465
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Spectroscopy focusing array (SFA) and polarimetry focusing array (PFA) are the two major payloads of the enhanced X-ray Timing and Polarimetry mission (eXTP). Nested Wolter-I X-ray mirror module is implemented in SFA and PFA to achieve a high effective area. When evaluating the properties of the mirror module, the alignment of the optical axis of the X-ray mirror module and a quasi-parallel X-ray beam is a prerequisite for ensuring accuracy of the results. To assist the alignment of the X-ray mirror module, an X-ray focal plane detector with one of the largest detection areas, is designed based on a back-illuminated scientific complementary metal-oxide-semiconductor transistor (sCMOS) sensor(GSENSE6060BSI; Gpixel Inc). Then the characteristics of readout noise, dark current, and split-pixel event properties of the detector are studied with the self-developed multi-target fluorescence X-ray source in a 100-m long X-ray test facility. The energy calibration is performed based on the single-pixel event, and the energy non-linearity of the detector is also observed. Finally, based on the optical model, the eXTP mirror module is simulated, and the alignment test of the Wolter-I X-ray mirror module designed for Einstein Probe/Follow-up X-ray Telescope via the ''Burkert test'' method is demonstrated.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Back-illuminated CCD for coherent soft X-ray imaging
    Beutier, G.
    van der Laan, G.
    Marty, A.
    Livet, F.
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2008, 42 (02): : 161 - 167
  • [2] Characterization of a BSI sCMOS for soft X-ray imaging spectroscopy
    Wang, W. X.
    Ling, Z. X.
    Zhang, C.
    Jia, Z. Q.
    Wang, X. Y.
    Wu, Q.
    Yuan, W. M.
    Zhang, S. N.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (02)
  • [3] Back-illuminated sCMOS technology boosts low-light imaging and spectroscopy applications
    Guntupalli, Ravi
    LASER FOCUS WORLD, 2017, 53 (01): : 80 - 83
  • [4] Photodetectors based on back-illuminated silicon photodiode arrays for X-ray imaging systems
    Goushcha, Ilja
    Tabbert, Bernd
    Popp, Andrew
    Goushcha, Alexander O.
    2007 IEEE Sensors Applications Symposium, 2007, : 127 - 132
  • [5] Measurement of the soft X-ray response of P-channel back-illuminated CCD
    Ueda, Shutaro
    Hayashida, Kiyoshi
    Nakajima, Hiroshi
    Anabuki, Naohisa
    Tsunemi, Hiroshi
    Kan, Hiroaki
    Kohmura, Takayoshi
    Ikeda, Shoma
    Kaneko, Kenta
    Watanabe, Tatsuo
    Mori, Koji
    Nobukawa, Masayoshi
    Murakami, Hiroshi
    Sakata, Kazuya
    Todoroki, Shotaro
    Yagihashi, Nobuyoshi
    Mizuno, Eiki
    Muramatsu, Masaharu
    Suzuki, Hisanori
    Takagi, Shin'ichiro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 704 : 140 - 146
  • [6] Improving the performance of the GOES solar X-ray imager (SXI) with a back-illuminated X-ray sensitive CCD
    Berthiaume, GD
    Burke, BE
    Gregory, JA
    Bornmann, PL
    GOES-8 AND BEYOND, 1996, 2812 : 552 - 558
  • [7] High-speed back-illuminated CMOS sensor for photon-counting-type imaging-spectroscopy in the soft X-ray range
    Narukage, Noriyuki
    Ishikawa, Shin-nosuke
    Sakao, Taro
    Wang, Xinyang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 950 (950):
  • [8] Soft X-ray responsivities of fully depleted back-illuminated charge-coupled device
    Miyata, Emi
    Ozawa, Hideki
    Matsuura, Daisuke
    Ikegami, Kazuhiro
    Tohiguchi, Masakuni
    Tsunemi, Hiroshi
    Miyaguchi, Kazuhisa
    Muramatsu, Masaharu
    Suzuki, Hisanori
    Japanese Journal of Applied Physics, Part 2: Letters, 2006, 45 (20-23):
  • [9] Soft X-ray responsivities of fully depleted back-illuminated charge-coupled device
    Miyata, Emi
    Ozawa, Hideki
    Matsuura, Daisuke
    Ikegami, Kazuhiro
    Tohiguchi, Masakuni
    Tsunemi, Hiroshi
    Miyaguchi, Kazuhisa
    Muramatsu, Masaharu
    Suzuki, Hisanori
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2006, 45 (20-23): : L572 - L574
  • [10] DEPFET based focal plane instrumentation for X-ray imaging spectroscopy in space
    Treis, J.
    Andricek, L.
    Herrmann, S.
    Heinzinger, K.
    Lauf, T.
    Lechner, P.
    Lutz, G.
    Mas-Hesse, J. M.
    Porro, M.
    Richter, R. H.
    Schaller, G.
    Schnecke, M.
    Schopper, F.
    Segneri, G.
    Soltau, H.
    Stevenson, T.
    Strueder, L.
    Whitford, C.
    Woelfel, S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2226 - +