Assessment and improvements of Geant4 hadronic models in the context of prompt-gamma hadrontherapy monitoring

被引:32
|
作者
Dedes, G. [1 ,2 ]
Pinto, M. [1 ,2 ]
Dauvergne, D. [1 ,2 ]
Freud, N. [3 ]
Krimmer, J. [1 ,2 ]
Letang, J. M. [3 ]
Ray, C. [1 ,2 ]
Testa, E. [1 ,2 ]
机构
[1] Univ Lyon, Inst Phys Nucl Lyon, F-69003 Villeurbanne, France
[2] Univ Lyon 1, IN2P3 CNRS, UMR 5822, F-69622 Villeurbanne, France
[3] Univ Lyon 1, CREATIS, CNRS UMR 5220, Inserm U 1044,INSA Lyon,Ctr Leon Berard, F-69365 Lyon, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 07期
关键词
promot-gamma; hadrontherapy; Geant4; nuclear models; QMD; DYNAMICS; SIMULATION; EMISSION; RANGE;
D O I
10.1088/0031-9155/59/7/1747
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo simulations are nowadays essential tools for a wide range of research topics in the field of radiotherapy. They also play an important role in the effort to develop a real-time monitoring system for quality assurance in proton and carbon ion therapy, by means of prompt-gamma detection. The internal theoretical nuclear models of Monte Carlo simulation toolkits are of decisive importance for the accurate description of neutral or charged particle emission, produced by nuclear interactions between beam particles and target nuclei. We assess the performance of Geant4 nuclear models in the context of prompt-gamma emission, comparing them with experimental data from proton and carbon ion beams. As has been shown in the past and further indicated in our study, the prompt-gamma yields are consistently overestimated by Geant4 by a factor of about 100% to 200% over an energy range from 80 to 310 MeV/u for the case of C-12, and to a lesser extent for 160 MeV protons. Furthermore, we focus on the quantum molecular dynamics (QMD) modeling of ion-ion collisions, in order to optimize its description of light nuclei, which are abundant in the human body and mainly anticipated in hadrontherapy applications. The optimization has been performed by benchmarking QMD free parameters with well established nuclear properties. In addition, we study the effect of this optimization on charged particle emission. With the usage of the proposed parameter values, discrepancies reduce to less than 70%, with the highest values being attributed to the nucleon-ion induced prompt-gammas. This conclusion, also confirmed by the disagreement we observe in the case of proton beams, indicates the need for further investigation on nuclear models which describe proton and neutron induced nuclear reactions.
引用
收藏
页码:1747 / 1772
页数:26
相关论文
共 43 条
  • [41] Assessment of gamma-rays and fast neutron beam attenuation features of Er2O3-doped B2O3-ZnO-Bi2O3 glasses using XCOM and simulation codes (MCNP5 and Geant4)
    Lakshminarayana, G.
    Dong, M. G.
    Kumar, Ashok
    Elmahroug, Y.
    Wagh, Akshatha
    Lee, Dong-Eun
    Yoon, Jonghun
    Park, Taejoon
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2019, 125 (11):
  • [42] Assessment of gamma-rays and fast neutron beam attenuation features of Er2O3-doped B2O3–ZnO–Bi2O3 glasses using XCOM and simulation codes (MCNP5 and Geant4)
    G. Lakshminarayana
    M. G. Dong
    Ashok Kumar
    Y. Elmahroug
    Akshatha Wagh
    Dong-Eun Lee
    Jonghun Yoon
    Taejoon Park
    Applied Physics A, 2019, 125
  • [43] A Geant4 procedure for precise simulation of PGNAA prompt γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\gamma$$\end{document}-ray spectrum in a wide energy range up to 8 MeV
    Thanh Tai Chau
    Ngoc Son Pham
    Thien Thanh Tran
    Cong Phat Vo
    Van Tao Chau
    Journal of Radioanalytical and Nuclear Chemistry, 2024, 333 (6) : 2783 - 2792