Assessment and improvements of Geant4 hadronic models in the context of prompt-gamma hadrontherapy monitoring

被引:32
|
作者
Dedes, G. [1 ,2 ]
Pinto, M. [1 ,2 ]
Dauvergne, D. [1 ,2 ]
Freud, N. [3 ]
Krimmer, J. [1 ,2 ]
Letang, J. M. [3 ]
Ray, C. [1 ,2 ]
Testa, E. [1 ,2 ]
机构
[1] Univ Lyon, Inst Phys Nucl Lyon, F-69003 Villeurbanne, France
[2] Univ Lyon 1, IN2P3 CNRS, UMR 5822, F-69622 Villeurbanne, France
[3] Univ Lyon 1, CREATIS, CNRS UMR 5220, Inserm U 1044,INSA Lyon,Ctr Leon Berard, F-69365 Lyon, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 07期
关键词
promot-gamma; hadrontherapy; Geant4; nuclear models; QMD; DYNAMICS; SIMULATION; EMISSION; RANGE;
D O I
10.1088/0031-9155/59/7/1747
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo simulations are nowadays essential tools for a wide range of research topics in the field of radiotherapy. They also play an important role in the effort to develop a real-time monitoring system for quality assurance in proton and carbon ion therapy, by means of prompt-gamma detection. The internal theoretical nuclear models of Monte Carlo simulation toolkits are of decisive importance for the accurate description of neutral or charged particle emission, produced by nuclear interactions between beam particles and target nuclei. We assess the performance of Geant4 nuclear models in the context of prompt-gamma emission, comparing them with experimental data from proton and carbon ion beams. As has been shown in the past and further indicated in our study, the prompt-gamma yields are consistently overestimated by Geant4 by a factor of about 100% to 200% over an energy range from 80 to 310 MeV/u for the case of C-12, and to a lesser extent for 160 MeV protons. Furthermore, we focus on the quantum molecular dynamics (QMD) modeling of ion-ion collisions, in order to optimize its description of light nuclei, which are abundant in the human body and mainly anticipated in hadrontherapy applications. The optimization has been performed by benchmarking QMD free parameters with well established nuclear properties. In addition, we study the effect of this optimization on charged particle emission. With the usage of the proposed parameter values, discrepancies reduce to less than 70%, with the highest values being attributed to the nucleon-ion induced prompt-gammas. This conclusion, also confirmed by the disagreement we observe in the case of proton beams, indicates the need for further investigation on nuclear models which describe proton and neutron induced nuclear reactions.
引用
收藏
页码:1747 / 1772
页数:26
相关论文
共 43 条
  • [11] Improvements of Preequilibrium and Evaporation Models in Geant4
    Quesada, J. M.
    Cortes, M. A.
    Howard, A.
    Folger, G.
    Ivanchenko, V. N.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 122 - +
  • [12] Validation of Geant4 Hadronic Physics Models at Intermediate Energies
    Banerjee, S.
    Cirrone, G. A. P.
    Elvira, V. D.
    Folger, G.
    Grichine, V.
    Heikkinen, A.
    Howard, A.
    Ivanchenko, V. N.
    Koi, T.
    Kossov, M.
    Molina, J. M. Quesada
    Ribon, A.
    Romano, F.
    Starkov, N.
    Wright, D.
    Yarba, J.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2073 - 2075
  • [13] Carbon fragmentation measurements and validation of the GEANT4 nuclear reaction models for hadrontherapy
    De Napoli, M.
    Agodi, C.
    Battistoni, G.
    Blancato, A. A.
    Cirrone, G. A. P.
    Cuttone, G.
    Giacoppo, F.
    Morone, M. C.
    Nicolosi, D.
    Pandola, L.
    Patera, V.
    Raciti, G.
    Rapisarda, E.
    Romano, F.
    Sardina, D.
    Sarti, A.
    Sciubba, A.
    Scuderi, V.
    Sfienti, C.
    Tropea, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22): : 7651 - 7671
  • [14] Validation of Geant4 Hadronic Physics Models at Intermediate Energies
    Banerjee, Sunanda
    17TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP09), 2010, 219
  • [15] Hadronic shower models in GEANT4: Validation strategy and results.
    Wellisch, JP
    PROCEEDINGS OF CHEP 2001, 2001, : 345 - 349
  • [16] Hadronic models validation in GEANT4 with CALICE highly granular calorimeters
    Ramilli, Marco
    XVTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR2012), 2012, 404
  • [17] Comparing hadronic models of GEANT4 for the neutron monitor response function
    Kang, Jeongsoo
    Kim, Yunho
    Son, Jae Bum
    Jang, Doh Yun
    Kim, Yong-Kyun
    Kim, Sung Joong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (06) : 1228 - 1233
  • [18] Evaluation of proton inelastic reaction models in Geant4 for prompt gamma production during proton radiotherapy
    Jeyasugiththan, Jeyasingam
    Peterson, Stephen W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (19): : 7617 - 7635
  • [19] Comparing hadronic models of GEANT4 for the neutron monitor response function
    Jeongsoo Kang
    Yunho Kim
    Jae Bum Son
    Doh Yun Jang
    Yong-Kyun Kim
    Sung Joong Kim
    Journal of the Korean Physical Society, 2013, 63 : 1228 - 1233
  • [20] Tissue Specific Characteristics of Prompt Gamma in Proton Radiotherapy: A GEANT4 Simulation Study
    Lau, A.
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2013, 40 (06)