Assessment and improvements of Geant4 hadronic models in the context of prompt-gamma hadrontherapy monitoring

被引:32
|
作者
Dedes, G. [1 ,2 ]
Pinto, M. [1 ,2 ]
Dauvergne, D. [1 ,2 ]
Freud, N. [3 ]
Krimmer, J. [1 ,2 ]
Letang, J. M. [3 ]
Ray, C. [1 ,2 ]
Testa, E. [1 ,2 ]
机构
[1] Univ Lyon, Inst Phys Nucl Lyon, F-69003 Villeurbanne, France
[2] Univ Lyon 1, IN2P3 CNRS, UMR 5822, F-69622 Villeurbanne, France
[3] Univ Lyon 1, CREATIS, CNRS UMR 5220, Inserm U 1044,INSA Lyon,Ctr Leon Berard, F-69365 Lyon, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 07期
关键词
promot-gamma; hadrontherapy; Geant4; nuclear models; QMD; DYNAMICS; SIMULATION; EMISSION; RANGE;
D O I
10.1088/0031-9155/59/7/1747
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo simulations are nowadays essential tools for a wide range of research topics in the field of radiotherapy. They also play an important role in the effort to develop a real-time monitoring system for quality assurance in proton and carbon ion therapy, by means of prompt-gamma detection. The internal theoretical nuclear models of Monte Carlo simulation toolkits are of decisive importance for the accurate description of neutral or charged particle emission, produced by nuclear interactions between beam particles and target nuclei. We assess the performance of Geant4 nuclear models in the context of prompt-gamma emission, comparing them with experimental data from proton and carbon ion beams. As has been shown in the past and further indicated in our study, the prompt-gamma yields are consistently overestimated by Geant4 by a factor of about 100% to 200% over an energy range from 80 to 310 MeV/u for the case of C-12, and to a lesser extent for 160 MeV protons. Furthermore, we focus on the quantum molecular dynamics (QMD) modeling of ion-ion collisions, in order to optimize its description of light nuclei, which are abundant in the human body and mainly anticipated in hadrontherapy applications. The optimization has been performed by benchmarking QMD free parameters with well established nuclear properties. In addition, we study the effect of this optimization on charged particle emission. With the usage of the proposed parameter values, discrepancies reduce to less than 70%, with the highest values being attributed to the nucleon-ion induced prompt-gammas. This conclusion, also confirmed by the disagreement we observe in the case of proton beams, indicates the need for further investigation on nuclear models which describe proton and neutron induced nuclear reactions.
引用
收藏
页码:1747 / 1772
页数:26
相关论文
共 43 条
  • [21] Test of hadronic interaction models in GEANT4 at low energy using the BESIII data
    Cao, G. F.
    He, M.
    Liu, H. M.
    Deng, Z. Y.
    Yuan, Y.
    Liang, Y. T.
    Fu, C. D.
    Liu, Y.
    Zhu, C.
    Li, W. D.
    Mao, Z. P.
    He, K. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 606 (03): : 700 - 707
  • [22] Impacts of Geant4 hadronic physics models on secondary particle productions in proton therapy simulations
    Lai, Pham Thi Cam
    Hai, Vo Hong
    Phuc, Nguyen Tri Toan
    RADIATION PHYSICS AND CHEMISTRY, 2025, 229
  • [23] Comparing Geant4 hadronic models for the WENDI-II rem meter response function
    Vanaudenhove, T.
    Dubus, A.
    Pauly, N.
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) : 340 - 345
  • [24] Reconstruction of Irradiation Field from Prompt Gamma-rays in Geant4 Based Proton Therapy Simulation
    Aso, T.
    Mastushita, K.
    Nishio, T.
    Kabuki, S.
    Sasaki, T.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [25] Proton Therapy Range Verification Using Prompt Gamma Rays: A Simulation Study with the Geant4 Monte Carlo Toolkit
    Lau, A.
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [26] COMPARISON OF VARIOUS MODELS OF MONTE CARLO GEANT 4 CODE IN SIMULATIONS OF PROMPT GAMMA PRODUCTION
    Chrobak, A.
    Konefal, A.
    Wronska, A.
    Magiera, A.
    Rusiecka, K.
    Laihem, K.
    Boeckenhoff, D.
    Feyen, S.
    ACTA PHYSICA POLONICA B, 2017, 48 (03): : 675 - 678
  • [27] Investigating the aberration found in 4.438 MeV 12C photo peak of the Geant4 simulated prompt gamma spectrum
    Ramanathan, V.
    Peterson, S.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [28] Range Verification using Prompt Gamma-rays with Energy Spectral Analysis in Geant4 Based Proton Therapy Simulation
    Aso, Tsukasa
    Oke, Hiroki
    Nishio, Teiji
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [29] A Simulation Study with Geant4 Investigating the Secondary Prompt Gamma Emissions From Incident 40 MeV Protons Onto Various Materials
    Lau, A.
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3773 - 3773
  • [30] Non-convergence of Geant4 hadronic models for 10 and 30 MeV protons in 18O and 14N
    Chin, M. P. W.
    Spyrou, N. M.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (03) : 406 - 414