Assessment and improvements of Geant4 hadronic models in the context of prompt-gamma hadrontherapy monitoring

被引:32
|
作者
Dedes, G. [1 ,2 ]
Pinto, M. [1 ,2 ]
Dauvergne, D. [1 ,2 ]
Freud, N. [3 ]
Krimmer, J. [1 ,2 ]
Letang, J. M. [3 ]
Ray, C. [1 ,2 ]
Testa, E. [1 ,2 ]
机构
[1] Univ Lyon, Inst Phys Nucl Lyon, F-69003 Villeurbanne, France
[2] Univ Lyon 1, IN2P3 CNRS, UMR 5822, F-69622 Villeurbanne, France
[3] Univ Lyon 1, CREATIS, CNRS UMR 5220, Inserm U 1044,INSA Lyon,Ctr Leon Berard, F-69365 Lyon, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 07期
关键词
promot-gamma; hadrontherapy; Geant4; nuclear models; QMD; DYNAMICS; SIMULATION; EMISSION; RANGE;
D O I
10.1088/0031-9155/59/7/1747
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo simulations are nowadays essential tools for a wide range of research topics in the field of radiotherapy. They also play an important role in the effort to develop a real-time monitoring system for quality assurance in proton and carbon ion therapy, by means of prompt-gamma detection. The internal theoretical nuclear models of Monte Carlo simulation toolkits are of decisive importance for the accurate description of neutral or charged particle emission, produced by nuclear interactions between beam particles and target nuclei. We assess the performance of Geant4 nuclear models in the context of prompt-gamma emission, comparing them with experimental data from proton and carbon ion beams. As has been shown in the past and further indicated in our study, the prompt-gamma yields are consistently overestimated by Geant4 by a factor of about 100% to 200% over an energy range from 80 to 310 MeV/u for the case of C-12, and to a lesser extent for 160 MeV protons. Furthermore, we focus on the quantum molecular dynamics (QMD) modeling of ion-ion collisions, in order to optimize its description of light nuclei, which are abundant in the human body and mainly anticipated in hadrontherapy applications. The optimization has been performed by benchmarking QMD free parameters with well established nuclear properties. In addition, we study the effect of this optimization on charged particle emission. With the usage of the proposed parameter values, discrepancies reduce to less than 70%, with the highest values being attributed to the nucleon-ion induced prompt-gammas. This conclusion, also confirmed by the disagreement we observe in the case of proton beams, indicates the need for further investigation on nuclear models which describe proton and neutron induced nuclear reactions.
引用
收藏
页码:1747 / 1772
页数:26
相关论文
共 43 条
  • [31] Preliminary assessment of Geant4 HP models and cross section libraries by reactor criticality benchmark calculations
    Cai, Xiao-Xiao
    Llamas-Jansa, Isabel
    Mullet, Steven
    Hval, Sverre
    Klinkby, Esben
    Kittelmann, Thomas
    Kanaki, Kalliopi
    Hall-Wilton, Richard
    Hauback, Bjrn C.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [32] Comparative study of alternative Geant4 hadronic ion inelastic physics models for prediction of positron-emitting radionuclide production in carbon and oxygen ion therapy
    Chacon, Andrew
    Guatelli, Susanna
    Rutherford, Harley
    Bolst, David
    Mohammadi, Akram
    Ahmed, Abdella
    Nitta, Munetaka
    Nishikido, Fumihiko
    Iwao, Yuma
    Tashima, Hideaki
    Yoshida, Eiji
    Akamatsu, Go
    Takyu, Sodai
    Kitagawa, Atsushi
    Hofmann, Theresa
    Pinto, Marco
    Franklin, Daniel R.
    Parodi, Katia
    Yamaya, Taiga
    Rosenfeld, Anatoly
    Safavi-Naeini, Mitra
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (15):
  • [33] REAL-TIME PROMPT GAMMA RAY MONITORING FOR PROTON AND CARBON THERAPY: MONTE CARLO NUCLEAR MODELS EVALUATION AND IMPROVEMENTS
    Dedes, G.
    Chevallier, M.
    Dauvergne, D.
    De Rydt, M.
    Freud, N.
    Krimmer, J.
    Letang, J. M.
    Pinto, M.
    Ray, C.
    Reithinger, V.
    Richard, M. H.
    Roellinghoff, F.
    Testa, E.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S68 - S69
  • [34] Monte Carlo nuclear models evaluation and improvements for real-time prompt gamma ray monitoring in proton and carbon therapy
    Dedes, George
    Dauvergne, Denis
    De Rydt, Marieke
    Freud, Nicolas
    Krimmer, Lochen
    Letang, Lean-Michel
    Pinto, Marco
    Ray, Cedric
    Testa, Etienne
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2564 - +
  • [35] Assessment of neutron- and proton-induced nuclear interaction and ionization models in Geant4 for simulating single event effects
    Truscott, P
    Lei, F
    Dyer, CS
    Frydland, A
    Clucas, S
    Trousse, B
    Hunter, K
    Comber, C
    Chugg, A
    Moutrie, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) : 3369 - 3374
  • [36] GEANT4 hadronic cascade models analysis of proton and charged pion transverse momentum spectra from p plus Cu and Pb collisions at 3, 8, and 15 GeV/c
    Abdel-Waged, Khaled
    Felemban, Nuha
    Uzhinskii, V. V.
    PHYSICAL REVIEW C, 2011, 84 (01):
  • [37] Gamma and infrared novel methodologies in Aerospace re-entry: γ-rays crystal efficiency by GEANT4 for TPS material recession assessment and simultaneous dual color infrared temperature determination
    De Cesare, M.
    Savino, L.
    Di Leva, A.
    Rapagnani, D.
    Del Vecchio, A.
    D'Onofrio, A.
    Gialanella, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 479 : 264 - 271
  • [38] Assessment of gamma-radiation attenuation characteristics of Bi2O3-B2O3-SiO2-Na2O glasses using Geant4 simulation code
    Sayyed, M., I
    Olarinoye, O., I
    Elsafi, Mohamed
    EUROPEAN PHYSICAL JOURNAL PLUS, 2021, 136 (05):
  • [39] Gamma and infrared novel methodologies in aerospace re-entry: γ-rays crystal efficiency by GEANT4 for TPS material recession assessment and simultaneous dual color infrared temperature determination (vol 479, pg 264, 2020)
    De Cesare, M.
    Savino, L.
    Di Leva, A.
    Rapagnani, D.
    Del Vecchio, A.
    D'Onofrio, A.
    Gialanella, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2022, 527 : 28 - 28
  • [40] Assessment of gamma-radiation attenuation characteristics of Bi2O3–B2O3–SiO2–Na2O glasses using Geant4 simulation code
    M. I. Sayyed
    O. I. Olarinoye
    Mohamed Elsafi
    The European Physical Journal Plus, 136