Differences of FreeStyle Libre Flash Glucose Monitoring System and Finger Pricks on Clinical Characteristics and Glucose Monitoring Satisfactions in Type 1 Diabetes Using Insulin Pump

被引:28
|
作者
Al Hayek, Ayman A. [1 ]
Robert, Asirvatham A. [1 ]
Al Dawish, Mohamed A. [1 ]
机构
[1] Prince Sultan Mil Med City, Diabet Treatment Ctr, Dept Endocrinol & Diabet, POB 7897, Riyadh 11159, Saudi Arabia
关键词
Type; 1; diabetes; finger pricks; freestyle libre; satisfaction; glycemic control; hypoglycemia; self-testing; GLYCEMIC CONTROL; RISK-FACTORS; MULTICENTER; ADOLESCENTS; HYPOGLYCEMIA; FREQUENCY; CHILDREN; PEOPLE; LIFE; FEAR;
D O I
10.1177/1179551419861102
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: To evaluate the different experience of freestyle libre and finger pricks on clinical characteristics and glucose monitoring satisfaction (GMS) in patients with type 1 diabetes (T1D) using insulin pump (IP). METHODS: A prospective study was carried out on 47 (aged 17-21 years) T1D. who used conventional finger-pricking method for self-testing the glucose. The experiments were conducted between March 2018 and September 2018. For carrying out the study, the flash glucose monitoring (FGM) sensors were placed on each participant. at the baseline visit. by a trained diabetes educator. Furthermore. to determine the total number of scans conducted during the study period, the respective ambulatory glucose profiles were generated by computing the data collected from the sensors. In addition, a trained interviewer handed over the GMS questionnaire to each patient. at the baseline and at 12 weeks of the study. RESULTS: In comparison to the baseline (finger pricks), various parameters such as: HbA1c (P= .042), hypoglycemia (P= .001), mean capillary glucose (P= .004), total daily insulin dose (P= .0001), percentage of bolus insulin (P= .0001), daily bolus frequency (P= .0001), and daily carbohydrates intake (P= .0001) showed a significant improvement at 12 weeks. Similarly, substantial augmentation was noticed. in the sub domains of GMS. that is, openness (P= .0001), emotional burden (P= .0001), behavioral burden (P= .0001). and trust (P= .0001) at 12 weeks as compared to baseline. Overall. total GMS score at baseline was 1.72 +/- 0.37, which increased up to 3.41 +/- 0.49 (P= .0001) in the time period of 12 weeks. The HbA1c (r(2) = 0.45), hypoglycemia (r(2)=0.58), and the mean number of FGM scans, exhibited a negative correlation, while GMS (r(2)= 0.52) and the mean number of FGM scans, exhibited a positive correlation. CONCLUSION: The frequency of hypoglycemia. HbA1c level. capillary glucose, daily carbohydrates intake decreased. while the total daily insulin dose, daily bolus insulin and total GMS score increased with the use of FGM scanning for 12 weeks.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Approach to Using Trend Arrows in the FreeStyle Libre Flash Glucose Monitoring Systems in Adults
    Kudva, Yogish C.
    Ahmann, Andrew J.
    Bergenstal, Richard M.
    Gavin, James R., III
    Kruger, Davida F.
    Midyett, L. Kurt
    Miller, Eden
    Harris, Dennis R.
    JOURNAL OF THE ENDOCRINE SOCIETY, 2018, 2 (12): : 1320 - 1337
  • [32] The FreeStyle Libre flash glucose monitoring system: how it has improved glycaemic control for people with type 1 diabetes in Eastern Cheshire, UK
    Yadegarfar, Ghasem
    Anderson, Simon G.
    Khawaja, Zohaib
    Cortes, Gabriela
    Leivesley, Kathryn
    Metters, Ann
    Horne, Linda
    Steele, Tom
    Heald, Adrian H.
    CARDIOVASCULAR ENDOCRINOLOGY & METABOLISM, 2020, 9 (04): : 171 - 176
  • [33] IMPACT OF FREESTYLE LIBRE FLASH GLUCOSE MONITORING SYSTEM ON GLYCEMIC CONTROL AND QUALITY OF LIFE IN PATIENTS WITH TYPE 1 DIABETES: CROATIAN PROSPECTIVE STUDY
    Varzic, S. Canecki
    Steiner, K.
    Centner, M. Gradinjan
    Krizevac, I. Prpic
    Curcic, I. Bilic
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A122 - A122
  • [34] Flash glucose monitoring with the FreeStyle Libre 2 compared with self-monitoring of blood glucose in suboptimally controlled type 1 diabetes: the FLASH-UK randomised controlled trial protocol
    Wilmot, Emma G.
    Evans, Mark
    Barnard-Kelly, Katharine
    Burns, M.
    Cranston, Iain
    Elliott, Rachel Ann
    Gkountouras, G.
    Kanumilli, N.
    Krishan, A.
    Kotonya, C.
    Lumley, S.
    Narendran, P.
    Neupane, Sankalpa
    Rayman, Gerry
    Sutton, Christopher
    Taxiarchi, V. P.
    Thabit, H.
    Leelarathna, L.
    BMJ OPEN, 2021, 11 (07):
  • [35] Audit of Libre flash glucose monitoring system use in young adults with type 1 diabetes mellitus
    Kgosidialwa, O.
    Colfer, M.
    Murray, G.
    Moore, A.
    Smith, D.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2019, 188 : S245 - S245
  • [36] Budget Impact Analysis of the FreeStyle Libre Flash Continuous Glucose Monitoring -System® in Patients with Type 1 Diabetes Mellitus and Type 2 Diabetes Mellitus with Multiple Daily Insulin Injections in Argentina
    Palacios, Alfredo
    Rodriguez-Cairoli, Federico
    Balan, Dario
    Rojas-Roque, Carlos
    Moreno-Lopez, Carolina
    Braun, Barbara
    Augustovski, Federico
    Pichon-Riviere, Andres
    Bardach, Ariel
    APPLIED HEALTH ECONOMICS AND HEALTH POLICY, 2023, 21 (04) : 637 - 650
  • [37] Budget Impact Analysis of the FreeStyle Libre Flash Continuous Glucose Monitoring System® in Patients with Type 1 Diabetes Mellitus and Type 2 Diabetes Mellitus with Multiple Daily Insulin Injections in Argentina
    Alfredo Palacios
    Federico Rodriguez-Cairoli
    Dario Balan
    Carlos Rojas-Roque
    Carolina Moreno-López
    Barbara Braun
    Federico Augustovski
    Andrés Pichon-Riviere
    Ariel Bardach
    Applied Health Economics and Health Policy, 2023, 21 : 637 - 650
  • [39] Accuracy of FreeStyle Libre flash glucose monitoring in patients with type 2 diabetes who migrated from highlands to plains
    Sun, Zeng-Mei
    Du, Yuan-Ze
    Wang, Su-Yuan
    Sun, Shu-Yao
    Ye, Yan
    Sun, Xue-Ping
    Li, Ming-Xia
    He, Hua
    Long, Wun-Chun
    Zhang, Cheng-Hui
    Yao, Xuan-Yu
    Fan, Wu-Yi
    Wang, Ling
    Wu, Yun-Hong
    WORLD JOURNAL OF DIABETES, 2024, 15 (06)
  • [40] Application of the FreeStyle®Libre Glucose Monitoring System in type 1 diabetes mellitus patients aged 1-4 years
    Li, Yangshiyu
    Cao, Bingyan
    Chen, Qiong
    Du, Mengmeng
    Yan, Mingming
    Chen, Yongxing
    Wei, Haiyan
    Wu, Xue
    Cui, Yan
    Liu, Fang
    PEDIATRIC DIABETES, 2022, 23 (05) : 604 - 610