Differences of FreeStyle Libre Flash Glucose Monitoring System and Finger Pricks on Clinical Characteristics and Glucose Monitoring Satisfactions in Type 1 Diabetes Using Insulin Pump

被引:28
|
作者
Al Hayek, Ayman A. [1 ]
Robert, Asirvatham A. [1 ]
Al Dawish, Mohamed A. [1 ]
机构
[1] Prince Sultan Mil Med City, Diabet Treatment Ctr, Dept Endocrinol & Diabet, POB 7897, Riyadh 11159, Saudi Arabia
关键词
Type; 1; diabetes; finger pricks; freestyle libre; satisfaction; glycemic control; hypoglycemia; self-testing; GLYCEMIC CONTROL; RISK-FACTORS; MULTICENTER; ADOLESCENTS; HYPOGLYCEMIA; FREQUENCY; CHILDREN; PEOPLE; LIFE; FEAR;
D O I
10.1177/1179551419861102
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: To evaluate the different experience of freestyle libre and finger pricks on clinical characteristics and glucose monitoring satisfaction (GMS) in patients with type 1 diabetes (T1D) using insulin pump (IP). METHODS: A prospective study was carried out on 47 (aged 17-21 years) T1D. who used conventional finger-pricking method for self-testing the glucose. The experiments were conducted between March 2018 and September 2018. For carrying out the study, the flash glucose monitoring (FGM) sensors were placed on each participant. at the baseline visit. by a trained diabetes educator. Furthermore. to determine the total number of scans conducted during the study period, the respective ambulatory glucose profiles were generated by computing the data collected from the sensors. In addition, a trained interviewer handed over the GMS questionnaire to each patient. at the baseline and at 12 weeks of the study. RESULTS: In comparison to the baseline (finger pricks), various parameters such as: HbA1c (P= .042), hypoglycemia (P= .001), mean capillary glucose (P= .004), total daily insulin dose (P= .0001), percentage of bolus insulin (P= .0001), daily bolus frequency (P= .0001), and daily carbohydrates intake (P= .0001) showed a significant improvement at 12 weeks. Similarly, substantial augmentation was noticed. in the sub domains of GMS. that is, openness (P= .0001), emotional burden (P= .0001), behavioral burden (P= .0001). and trust (P= .0001) at 12 weeks as compared to baseline. Overall. total GMS score at baseline was 1.72 +/- 0.37, which increased up to 3.41 +/- 0.49 (P= .0001) in the time period of 12 weeks. The HbA1c (r(2) = 0.45), hypoglycemia (r(2)=0.58), and the mean number of FGM scans, exhibited a negative correlation, while GMS (r(2)= 0.52) and the mean number of FGM scans, exhibited a positive correlation. CONCLUSION: The frequency of hypoglycemia. HbA1c level. capillary glucose, daily carbohydrates intake decreased. while the total daily insulin dose, daily bolus insulin and total GMS score increased with the use of FGM scanning for 12 weeks.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Budget impact analysis of the freestyle libre flash continuous glucose monitoring system® in patients with diabetes mellitus type 1 in Chile
    Palacios, Alfredo
    Cairoli, Federico Rodriguez
    Balan, Dario
    Balmaceda, Carlos
    Augustovski, Federico
    Pichon-Riviere, Andres
    Bardach, Ariel
    EXPERT REVIEW OF PHARMACOECONOMICS & OUTCOMES RESEARCH, 2023, 23 (03) : 353 - 363
  • [22] AGP in daily clinical practice: a guide for use with the FreeStyle Libre flash glucose monitoring system
    Gibb, Fraser W.
    Jennings, Peter
    Leelarathna, Lalantha
    Wilmot, Emma G.
    BRITISH JOURNAL OF DIABETES, 2020, 20 (01): : 32 - 40
  • [23] Efficacy and safety of Freestyle Libre glucose monitoring system: A retrospective study of adults with Type 1 diabetes
    Jordan, E. V.
    DIABETIC MEDICINE, 2019, 36 : 145 - 146
  • [24] CLINICAL ACCURACY EVALUATION OF FREESTYLE LIBRE FLASH GLUCOSE MONITORING SYSTEM WHEN USED BY CHILDREN AND YOUNG PEOPLE WITH DIABETES
    Campbell, F.
    Edge, J.
    Acerini, C.
    Hamilton-Shield, J.
    Moudiotis, C.
    Rahman, S.
    Randell, T.
    Smith, A.
    Trevelyan, N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 : A29 - A29
  • [25] Evaluation of the FreeStyle Libre, a flash glucose monitoring system, in client-owned cats with diabetes mellitus
    Knies, Marieke
    Teske, Erik
    Kooistra, Hans
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2022, 24 (08) : E223 - E231
  • [26] THE FREESTYLE LIBRE FLASH GLUCOSE MONITORING SYSTEM IMPROVES MENTAL WELL-BEING AND TREATMENT SATISFACTION IN PATIENTS WITH TYPE 1 DIABETES
    Al Hayek, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A116 - A116
  • [27] Performance of the Freestyle Libre flash glucose monitoring (flash GM) system in individuals with type 1 diabetes: A secondary outcome analysis of a randomized crossover trial
    Moser, Othmar
    Eckstein, Max L.
    McCarthy, Olivia
    Deere, Rachel
    Pitt, Jason
    Williams, David M.
    Hayes, Jennifer
    Sourij, Harald
    Bain, Stephen C.
    Bracken, Richard M.
    DIABETES OBESITY & METABOLISM, 2019, 21 (11): : 2505 - 2512
  • [28] Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes
    Wen, Xiaofang
    Zeng, Nan
    Zhang, Ningbo
    Ou, Tingting
    Li, Xiaowei
    Li, Xiaoying
    Li, Wangen
    Xu, Kang
    Du, Tao
    DIABETES METABOLIC SYNDROME AND OBESITY, 2022, 15 : 3437 - 3445
  • [29] GLUCOSE EXCURSION IN TYPE 1 DIABETES AUDIT COMBINING ABBOTT FLASH GLUCOSE MONITORING AND CELLNOVO INSULIN PUMP
    Kelly, P.
    Jennings, P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A147 - A148
  • [30] Practical guidance for using the FreeStyle Libre flash continuous glucose monitoring in primary care
    Unger, Jeff
    Kushner, Pamela
    Anderson, John E.
    POSTGRADUATE MEDICINE, 2020, 132 (04) : 305 - 313