Differences of FreeStyle Libre Flash Glucose Monitoring System and Finger Pricks on Clinical Characteristics and Glucose Monitoring Satisfactions in Type 1 Diabetes Using Insulin Pump

被引:28
|
作者
Al Hayek, Ayman A. [1 ]
Robert, Asirvatham A. [1 ]
Al Dawish, Mohamed A. [1 ]
机构
[1] Prince Sultan Mil Med City, Diabet Treatment Ctr, Dept Endocrinol & Diabet, POB 7897, Riyadh 11159, Saudi Arabia
关键词
Type; 1; diabetes; finger pricks; freestyle libre; satisfaction; glycemic control; hypoglycemia; self-testing; GLYCEMIC CONTROL; RISK-FACTORS; MULTICENTER; ADOLESCENTS; HYPOGLYCEMIA; FREQUENCY; CHILDREN; PEOPLE; LIFE; FEAR;
D O I
10.1177/1179551419861102
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: To evaluate the different experience of freestyle libre and finger pricks on clinical characteristics and glucose monitoring satisfaction (GMS) in patients with type 1 diabetes (T1D) using insulin pump (IP). METHODS: A prospective study was carried out on 47 (aged 17-21 years) T1D. who used conventional finger-pricking method for self-testing the glucose. The experiments were conducted between March 2018 and September 2018. For carrying out the study, the flash glucose monitoring (FGM) sensors were placed on each participant. at the baseline visit. by a trained diabetes educator. Furthermore. to determine the total number of scans conducted during the study period, the respective ambulatory glucose profiles were generated by computing the data collected from the sensors. In addition, a trained interviewer handed over the GMS questionnaire to each patient. at the baseline and at 12 weeks of the study. RESULTS: In comparison to the baseline (finger pricks), various parameters such as: HbA1c (P= .042), hypoglycemia (P= .001), mean capillary glucose (P= .004), total daily insulin dose (P= .0001), percentage of bolus insulin (P= .0001), daily bolus frequency (P= .0001), and daily carbohydrates intake (P= .0001) showed a significant improvement at 12 weeks. Similarly, substantial augmentation was noticed. in the sub domains of GMS. that is, openness (P= .0001), emotional burden (P= .0001), behavioral burden (P= .0001). and trust (P= .0001) at 12 weeks as compared to baseline. Overall. total GMS score at baseline was 1.72 +/- 0.37, which increased up to 3.41 +/- 0.49 (P= .0001) in the time period of 12 weeks. The HbA1c (r(2) = 0.45), hypoglycemia (r(2)=0.58), and the mean number of FGM scans, exhibited a negative correlation, while GMS (r(2)= 0.52) and the mean number of FGM scans, exhibited a positive correlation. CONCLUSION: The frequency of hypoglycemia. HbA1c level. capillary glucose, daily carbohydrates intake decreased. while the total daily insulin dose, daily bolus insulin and total GMS score increased with the use of FGM scanning for 12 weeks.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Flash glucose monitoring and glycemic control in type 1 diabetes with subcutaneous insulin infusion flash glucose monitoring and glycemic control
    Pinheiro, Sara Lomelino
    Bastos, Margarida
    Barros, Luisa
    Melo, Miguel
    Paiva, Isabel
    ACTA DIABETOLOGICA, 2022, 59 (04) : 509 - 515
  • [42] Optimising use of rate-of-change trend arrows for insulin dosing decisions using the FreeStyle Libre flash glucose monitoring system
    Ajjan, Ramzi A.
    Cummings, Michael H.
    Jennings, Peter
    Leelarathna, Lalantha
    Rayman, Gerry
    Wilmot, Emma G.
    DIABETES & VASCULAR DISEASE RESEARCH, 2019, 16 (01): : 3 - 12
  • [43] Cost analysis of the flash monitoring system (FreeStyle Libre 2) in adults with type 1 diabetes mellitus
    Oyaguez, Itziar
    Merino-Torres, Juan Francisco
    Brito, Miguel
    Bellido, Virginia
    Cardona-Hernandez, Roque
    Gomez-Peralta, Fernando
    Morales-Perez, Francisco
    BMJ OPEN DIABETES RESEARCH & CARE, 2020, 8 (01)
  • [44] Performance of the FreeStyle Libre Flash Glucose Monitoring System during an Oral Glucose Tolerance Test and Exercise in Healthy Adolescents
    Afeef, Sahar
    Tolfrey, Keith
    Zakrzewski-Fruer, Julia K.
    Barrett, Laura A.
    SENSORS, 2023, 23 (09)
  • [45] Flash Continuous Glucose Monitoring (FreeStyle Libre 14-Day System) for Self-Management of Diabetes Mellitus
    Choi, Hiu Ying Joanna
    AMERICAN FAMILY PHYSICIAN, 2021, 103 (11) : 688 - 690
  • [46] Comparison of oral glucose tolerance test and ambulatory glycaemic profiles in pregnant women in Uganda with gestational diabetes using the FreeStyle Libre flash glucose monitoring system
    Milln, J. M.
    Walugembe, E.
    Ssentayi, S.
    Nkabura, H.
    Jones, A. G.
    Nyirenda, M. J.
    BMC PREGNANCY AND CHILDBIRTH, 2020, 20 (01)
  • [47] A clinical trial of the accuracy and treatment experience of the flash glucose monitor FreeStyle Libre in persons with type 1 diabetes
    Olafsdottir, A. F.
    Attvall, S.
    Sandgren, U.
    Dahlqvist, S.
    Imberg, H.
    Skritc, S.
    Lind, M.
    DIABETOLOGIA, 2016, 59 : S411 - S411
  • [48] Role of Flash Glucose Monitoring System Combined With Insulin Pump in Blood Glucose Treatment of Patients with Type 2 Diabetes Mellitus
    Wang, Jinxia
    Zeng, Ting
    Cai, Lu
    Liu, Ping
    Wen, Honghua
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 83 : 102 - 105
  • [49] Comparison of oral glucose tolerance test and ambulatory glycaemic profiles in pregnant women in Uganda with gestational diabetes using the FreeStyle Libre flash glucose monitoring system
    J. M. Milln
    E. Walugembe
    S. Ssentayi
    H. Nkabura
    A. G. Jones
    M. J. Nyirenda
    BMC Pregnancy and Childbirth, 20
  • [50] A Clinical Trial of the Accuracy and Treatment Experience of the Flash Glucose Monitor FreeStyle Libre in Adults with Type 1 Diabetes
    Olafsdottir, Arndis F.
    Attvall, Stig
    Sandgren, Ulrika
    Dahlqvist, Sofia
    Pivodic, Aldina
    Skrtic, Stanko
    Theodorsson, Elvar
    Lind, Marcus
    DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 (03) : 164 - 172