Application of the FreeStyle®Libre Glucose Monitoring System in type 1 diabetes mellitus patients aged 1-4 years

被引:3
|
作者
Li, Yangshiyu [1 ]
Cao, Bingyan [2 ]
Chen, Qiong [1 ]
Du, Mengmeng [1 ]
Yan, Mingming [3 ]
Chen, Yongxing [1 ]
Wei, Haiyan [1 ]
Wu, Xue [1 ]
Cui, Yan [1 ]
Liu, Fang [1 ]
机构
[1] Zhengzhou Univ, Henan Childrens Hosp, Zhengzhou Childrens Hosp, Dept Endocrinol Genet & Metab,Childrens Hosp, Zhengzhou 450018, Peoples R China
[2] Capital Med Univ, Beijing Childrens Hosp, Natl Ctr Childrens Hlth, Dept Endocrinol Genet & Metab, Beijing, Peoples R China
[3] Zhengzhou Univ, Henan Childrens Hosp, Zhengzhou Childrens Hosp, Dept Stat & Epidemiol,Childrens Hosp, Zhengzhou, Peoples R China
关键词
blood glucose self-monitoring; child; diabetes mellitus; type; 1; personal satisfaction; RAPIDLY RISING INCIDENCE; ENDOCRINE-SOCIETY; MANAGEMENT; CHILDREN;
D O I
10.1111/pedi.13368
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background To investigate the analytical accuracy, safety performance, and user satisfaction (guardians of study participants) of the FreeStyle (R) Libre Glucose Monitoring System in the treatment of type 1 diabetes mellitus (T1DM), in children aged T1DM, aged 4 months to 4 years, were enrolled in this study. Patients wore the sensor for 14 days; sensor scans were performed immediately and at 5, 10, and 15 min after capillary blood glucose (BG) measurements to evaluate the effectiveness of the device and the lag effect. Results The consensus error grid showed that 96.40% of values fell within zone A (no clinical impact) and 3.60% within zone B (little/no clinical impact). Overall, the mean absolute relative difference (MARD) was 9.34%, and was higher in the capillary BG <4.0 mmol/L group (15.18%) than in the 4-10 mmol/L (9.63%) and >10 mmol/L (7.17%) groups. The MARD increased gradually with scanning time extension, indicating a short lag effect. Regression analysis showed that a higher BG level was associated with a greater difference in FreeStyle (R) Libre System measurements. Conclusions The use of the FreeStyle (R) Libre System in children aged 1-4 years is accurate and safe, and may be accurate down to 4 months, independent of patient characteristics.
引用
收藏
页码:604 / 610
页数:7
相关论文
共 50 条
  • [1] Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus
    Fokkert, M. J.
    van Dijk, P. R.
    Edens, M. A.
    Abbes, S.
    de Jong, D.
    Slingerland, R. J.
    Bilo, H. J. G.
    BMJ OPEN DIABETES RESEARCH & CARE, 2017, 5 (01):
  • [2] Benefits of using the Freestyle Libre flash glucose monitoring system for patients with type 1 diabetes
    Jones, A. M.
    DIABETIC MEDICINE, 2020, 37 : 64 - 65
  • [3] Budget impact analysis of the freestyle libre flash continuous glucose monitoring system® in patients with diabetes mellitus type 1 in Chile
    Palacios, Alfredo
    Cairoli, Federico Rodriguez
    Balan, Dario
    Balmaceda, Carlos
    Augustovski, Federico
    Pichon-Riviere, Andres
    Bardach, Ariel
    EXPERT REVIEW OF PHARMACOECONOMICS & OUTCOMES RESEARCH, 2023, 23 (03) : 353 - 363
  • [4] ACCEPTABILITY OF THE FREESTYLE LIBRE FLASH GLUCOSE MONITORING SYSTEM: THE EXPERIENCE OF YOUNG PATIENTS WITH TYPE 1 DIABETES
    Al Hayek, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A116 - A116
  • [5] Acceptability of the FreeStyle Libre Flash Glucose Monitoring System: The Experience of Young Patients With Type 1 Diabetes
    Al Hayek, Ayman A.
    Robert, Asirvatham A.
    Al Dawish, Mohamed A.
    CLINICAL MEDICINE INSIGHTS-ENDOCRINOLOGY AND DIABETES, 2020, 13
  • [6] Evaluation of the FreeStyle® Libre Flash Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes
    Massa, Guy G.
    Gys, Inge
    Op't Eyndt, Anniek
    Bevilacqua, Esmiralda
    Wijnands, Anne
    Declercq, Peter
    Zeevaert, Renate
    HORMONE RESEARCH IN PAEDIATRICS, 2018, 89 (03): : 189 - 199
  • [7] Cost analysis of the flash monitoring system (FreeStyle Libre 2) in adults with type 1 diabetes mellitus
    Oyaguez, Itziar
    Merino-Torres, Juan Francisco
    Brito, Miguel
    Bellido, Virginia
    Cardona-Hernandez, Roque
    Gomez-Peralta, Fernando
    Morales-Perez, Francisco
    BMJ OPEN DIABETES RESEARCH & CARE, 2020, 8 (01)
  • [8] Feasibility of FreeStyle Libre Flash Glucose Monitoring System in pregnant woman affected by type 1 diabetes
    Milo Gatti
    Acta Diabetologica, 2019, 56 : 481 - 483
  • [9] Feasibility of FreeStyle Libre Flash Glucose Monitoring System in pregnant woman affected by type 1 diabetes
    Gatti, Milo
    ACTA DIABETOLOGICA, 2019, 56 (04) : 481 - 483
  • [10] Efficacy and safety of Freestyle Libre glucose monitoring system: A retrospective study of adults with Type 1 diabetes
    Jordan, E. V.
    DIABETIC MEDICINE, 2019, 36 : 145 - 146