Application of the FreeStyle®Libre Glucose Monitoring System in type 1 diabetes mellitus patients aged 1-4 years

被引:3
|
作者
Li, Yangshiyu [1 ]
Cao, Bingyan [2 ]
Chen, Qiong [1 ]
Du, Mengmeng [1 ]
Yan, Mingming [3 ]
Chen, Yongxing [1 ]
Wei, Haiyan [1 ]
Wu, Xue [1 ]
Cui, Yan [1 ]
Liu, Fang [1 ]
机构
[1] Zhengzhou Univ, Henan Childrens Hosp, Zhengzhou Childrens Hosp, Dept Endocrinol Genet & Metab,Childrens Hosp, Zhengzhou 450018, Peoples R China
[2] Capital Med Univ, Beijing Childrens Hosp, Natl Ctr Childrens Hlth, Dept Endocrinol Genet & Metab, Beijing, Peoples R China
[3] Zhengzhou Univ, Henan Childrens Hosp, Zhengzhou Childrens Hosp, Dept Stat & Epidemiol,Childrens Hosp, Zhengzhou, Peoples R China
关键词
blood glucose self-monitoring; child; diabetes mellitus; type; 1; personal satisfaction; RAPIDLY RISING INCIDENCE; ENDOCRINE-SOCIETY; MANAGEMENT; CHILDREN;
D O I
10.1111/pedi.13368
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background To investigate the analytical accuracy, safety performance, and user satisfaction (guardians of study participants) of the FreeStyle (R) Libre Glucose Monitoring System in the treatment of type 1 diabetes mellitus (T1DM), in children aged T1DM, aged 4 months to 4 years, were enrolled in this study. Patients wore the sensor for 14 days; sensor scans were performed immediately and at 5, 10, and 15 min after capillary blood glucose (BG) measurements to evaluate the effectiveness of the device and the lag effect. Results The consensus error grid showed that 96.40% of values fell within zone A (no clinical impact) and 3.60% within zone B (little/no clinical impact). Overall, the mean absolute relative difference (MARD) was 9.34%, and was higher in the capillary BG <4.0 mmol/L group (15.18%) than in the 4-10 mmol/L (9.63%) and >10 mmol/L (7.17%) groups. The MARD increased gradually with scanning time extension, indicating a short lag effect. Regression analysis showed that a higher BG level was associated with a greater difference in FreeStyle (R) Libre System measurements. Conclusions The use of the FreeStyle (R) Libre System in children aged 1-4 years is accurate and safe, and may be accurate down to 4 months, independent of patient characteristics.
引用
收藏
页码:604 / 610
页数:7
相关论文
共 50 条
  • [42] Flash Continuous Glucose Monitoring (FreeStyle Libre 14-Day System) for Self-Management of Diabetes Mellitus
    Choi, Hiu Ying Joanna
    AMERICAN FAMILY PHYSICIAN, 2021, 103 (11) : 688 - 690
  • [43] Cost Analysis of FreeStyle Libre® 2 System in Type 2 Diabetes Mellitus Population
    Itziar Oyagüez
    Fernando Gómez-Peralta
    Sara Artola
    Francisco J. Carrasco
    Juana Carretero-Gómez
    Javier García-Soidan
    Ricardo Gómez-Huelgas
    Juan F. Merino-Torres
    Antonio Pérez
    Diabetes Therapy, 2021, 12 : 2329 - 2342
  • [44] Effectiveness of the freestyle libre 2 flash glucose monitoring system on diabetes-self-management practices and glycemic parameters among patients with type 1 diabetes using insulin pump
    Al Hayek, Ayman A.
    Robert, Asirvatham Alwin
    Al Dawish, Mohamed Abdulaziz
    DIABETES & METABOLIC SYNDROME-CLINICAL RESEARCH & REVIEWS, 2021, 15 (05)
  • [45] EFFECTIVENESS OF THE FREESTYLE LIBRE 2 FLASH GLUCOSE MONITORING SYSTEM ON DIABETES-SELF-MANAGEMENT PRACTICES AND GLYCEMIC PARAMETERS AMONG PATIENTS WITH TYPE 1 DIABETES USING INSULIN PUMP
    Al Hayek, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A128 - A128
  • [46] A Comparison of Continuous Glucose Monitors in Reducing MC in Type 1 and Type 2 Diabetes: FreeStyle Libre and Dexcom
    Miller, Eden
    Joseph, Jennifer
    Reyes, Ignacio J.
    Nabutovsky, Yelena
    Virdi, Naunihal
    Hirsch, Irl B.
    DIABETES, 2021, 70
  • [47] Impact of the FreeStyle Libre 2® System on Glycaemic Outcomes in Patients with Type 1 Diabetes-Preliminary Study
    Rutkowska, Katarzyna
    Los-Stegienta, Agnieszka
    Baginski, Michal
    Zieba, Ewa
    Baran, Adrianna
    Zurawska-Klis, Monika
    Kosinski, Marcin
    Cypryk, Katarzyna
    DIAGNOSTICS, 2024, 14 (16)
  • [48] Performance of the Freestyle Libre flash glucose monitoring (flash GM) system in individuals with type 1 diabetes: A secondary outcome analysis of a randomized crossover trial
    Moser, Othmar
    Eckstein, Max L.
    McCarthy, Olivia
    Deere, Rachel
    Pitt, Jason
    Williams, David M.
    Hayes, Jennifer
    Sourij, Harald
    Bain, Stephen C.
    Bracken, Richard M.
    DIABETES OBESITY & METABOLISM, 2019, 21 (11): : 2505 - 2512
  • [49] COMPARISON BETWEEN ISCGM FREESTYLE LIBRE 1, FREESTYLE LIBRE 2 AND CAPILLARY SMBG IN YOUNG PEOPLE WITHOUT DIABETES MELLITUS.
    Gerre, A.
    Londahl, E.
    Ziegler, K.
    Filipsson, K.
    Londahl, M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A144 - A145
  • [50] Continuous glucose monitoring in type 1 diabetes mellitus
    Pavlicek, Vojtech
    DIABETOLOGE, 2019, 15 (08): : 744 - 746