Application of the FreeStyle®Libre Glucose Monitoring System in type 1 diabetes mellitus patients aged 1-4 years

被引:3
|
作者
Li, Yangshiyu [1 ]
Cao, Bingyan [2 ]
Chen, Qiong [1 ]
Du, Mengmeng [1 ]
Yan, Mingming [3 ]
Chen, Yongxing [1 ]
Wei, Haiyan [1 ]
Wu, Xue [1 ]
Cui, Yan [1 ]
Liu, Fang [1 ]
机构
[1] Zhengzhou Univ, Henan Childrens Hosp, Zhengzhou Childrens Hosp, Dept Endocrinol Genet & Metab,Childrens Hosp, Zhengzhou 450018, Peoples R China
[2] Capital Med Univ, Beijing Childrens Hosp, Natl Ctr Childrens Hlth, Dept Endocrinol Genet & Metab, Beijing, Peoples R China
[3] Zhengzhou Univ, Henan Childrens Hosp, Zhengzhou Childrens Hosp, Dept Stat & Epidemiol,Childrens Hosp, Zhengzhou, Peoples R China
关键词
blood glucose self-monitoring; child; diabetes mellitus; type; 1; personal satisfaction; RAPIDLY RISING INCIDENCE; ENDOCRINE-SOCIETY; MANAGEMENT; CHILDREN;
D O I
10.1111/pedi.13368
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background To investigate the analytical accuracy, safety performance, and user satisfaction (guardians of study participants) of the FreeStyle (R) Libre Glucose Monitoring System in the treatment of type 1 diabetes mellitus (T1DM), in children aged T1DM, aged 4 months to 4 years, were enrolled in this study. Patients wore the sensor for 14 days; sensor scans were performed immediately and at 5, 10, and 15 min after capillary blood glucose (BG) measurements to evaluate the effectiveness of the device and the lag effect. Results The consensus error grid showed that 96.40% of values fell within zone A (no clinical impact) and 3.60% within zone B (little/no clinical impact). Overall, the mean absolute relative difference (MARD) was 9.34%, and was higher in the capillary BG <4.0 mmol/L group (15.18%) than in the 4-10 mmol/L (9.63%) and >10 mmol/L (7.17%) groups. The MARD increased gradually with scanning time extension, indicating a short lag effect. Regression analysis showed that a higher BG level was associated with a greater difference in FreeStyle (R) Libre System measurements. Conclusions The use of the FreeStyle (R) Libre System in children aged 1-4 years is accurate and safe, and may be accurate down to 4 months, independent of patient characteristics.
引用
收藏
页码:604 / 610
页数:7
相关论文
共 50 条
  • [21] THE FREESTYLE LIBRE FLASH GLUCOSE MONITORING SYSTEM IMPROVES MENTAL WELL-BEING AND TREATMENT SATISFACTION IN PATIENTS WITH TYPE 1 DIABETES
    Al Hayek, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A116 - A116
  • [22] Audit of Libre flash glucose monitoring system use in young adults with type 1 diabetes mellitus
    Kgosidialwa, O.
    Colfer, M.
    Murray, G.
    Moore, A.
    Smith, D.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2019, 188 : S245 - S245
  • [23] Evaluation of the FreeStyle Libre, a flash glucose monitoring system, in client-owned cats with diabetes mellitus
    Knies, Marieke
    Teske, Erik
    Kooistra, Hans
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2022, 24 (08) : E223 - E231
  • [24] IMPACT OF FREESTYLE LIBRE FLASH GLUCOSE MONITORING SYSTEM ON GLYCEMIC CONTROL AND QUALITY OF LIFE IN PATIENTS WITH TYPE 1 DIABETES: CROATIAN PROSPECTIVE STUDY
    Varzic, S. Canecki
    Steiner, K.
    Centner, M. Gradinjan
    Krizevac, I. Prpic
    Curcic, I. Bilic
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A122 - A122
  • [25] Comparison of glucose monitoring between Freestyle Libre Pro and iPro2 in patients with diabetes mellitus
    Kumagai, Ryo
    Muramatsu, Aiko
    Fujii, Masanao
    Katakura, Yukino
    Ito, Kei
    Fujie, Keiko
    Nakata, Yoshio
    Hashimoto, Koichi
    Yagyu, Hiroaki
    JOURNAL OF DIABETES INVESTIGATION, 2019, 10 (03) : 851 - 856
  • [26] Good Metabolic Control in Children with Type 1 Diabetes Mellitus: Does Glycated Hemoglobin Correlate with Interstitial Glucose Monitoring Using FreeStyle Libre?
    Porcel-Chacon, Rocio
    Antunez-Fernandez, Cristina
    Mora Loro, Maria
    Ariza-Jimenez, Ana-Belen
    Tapia Ceballos, Leopoldo
    Jimenez Hinojosa, Jose Manuel
    Lopez-Siguero, Juan Pedro
    Leiva Gea, Isabel
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (21)
  • [27] Insulin degludec overdose in an adolescent with type 1 diabetes: proactive management including monitoring using the Freestyle Libre flash glucose monitoring system
    Thompson, Harmony
    Lunt, Helen
    Fleckney, Cate
    Soule, Steven
    ENDOCRINOLOGY DIABETES AND METABOLISM CASE REPORTS, 2018,
  • [28] Cost-effectiveness analysis of glycaemic control of a glucose monitoring system (FreeStyle Libre®) for patients with type 1 diabetes in primary health care of Burgos
    Teresa Gil-Ibanez, Maria
    Rodrigo Aispuru, Gualberto
    ENFERMERIA CLINICA, 2020, 30 (02): : 82 - 88
  • [29] Differences of FreeStyle Libre Flash Glucose Monitoring System and Finger Pricks on Clinical Characteristics and Glucose Monitoring Satisfactions in Type 1 Diabetes Using Insulin Pump
    Al Hayek, Ayman A.
    Robert, Asirvatham A.
    Al Dawish, Mohamed A.
    CLINICAL MEDICINE INSIGHTS-ENDOCRINOLOGY AND DIABETES, 2019, 12
  • [30] Cost-effectiveness of continuous glucose monitoring with FreeStyle Libre® in Brazilian insulin-treated patients with types 1 and 2 diabetes mellitus
    Luciana Bahia
    Karla F. Mello
    Lívia Lovato Pires Lemos
    Naiane Lima Costa
    Eduardo Mulinari
    Domingos A. Malerbi
    Diabetology & Metabolic Syndrome, 15