Differences of FreeStyle Libre Flash Glucose Monitoring System and Finger Pricks on Clinical Characteristics and Glucose Monitoring Satisfactions in Type 1 Diabetes Using Insulin Pump

被引:28
|
作者
Al Hayek, Ayman A. [1 ]
Robert, Asirvatham A. [1 ]
Al Dawish, Mohamed A. [1 ]
机构
[1] Prince Sultan Mil Med City, Diabet Treatment Ctr, Dept Endocrinol & Diabet, POB 7897, Riyadh 11159, Saudi Arabia
关键词
Type; 1; diabetes; finger pricks; freestyle libre; satisfaction; glycemic control; hypoglycemia; self-testing; GLYCEMIC CONTROL; RISK-FACTORS; MULTICENTER; ADOLESCENTS; HYPOGLYCEMIA; FREQUENCY; CHILDREN; PEOPLE; LIFE; FEAR;
D O I
10.1177/1179551419861102
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: To evaluate the different experience of freestyle libre and finger pricks on clinical characteristics and glucose monitoring satisfaction (GMS) in patients with type 1 diabetes (T1D) using insulin pump (IP). METHODS: A prospective study was carried out on 47 (aged 17-21 years) T1D. who used conventional finger-pricking method for self-testing the glucose. The experiments were conducted between March 2018 and September 2018. For carrying out the study, the flash glucose monitoring (FGM) sensors were placed on each participant. at the baseline visit. by a trained diabetes educator. Furthermore. to determine the total number of scans conducted during the study period, the respective ambulatory glucose profiles were generated by computing the data collected from the sensors. In addition, a trained interviewer handed over the GMS questionnaire to each patient. at the baseline and at 12 weeks of the study. RESULTS: In comparison to the baseline (finger pricks), various parameters such as: HbA1c (P= .042), hypoglycemia (P= .001), mean capillary glucose (P= .004), total daily insulin dose (P= .0001), percentage of bolus insulin (P= .0001), daily bolus frequency (P= .0001), and daily carbohydrates intake (P= .0001) showed a significant improvement at 12 weeks. Similarly, substantial augmentation was noticed. in the sub domains of GMS. that is, openness (P= .0001), emotional burden (P= .0001), behavioral burden (P= .0001). and trust (P= .0001) at 12 weeks as compared to baseline. Overall. total GMS score at baseline was 1.72 +/- 0.37, which increased up to 3.41 +/- 0.49 (P= .0001) in the time period of 12 weeks. The HbA1c (r(2) = 0.45), hypoglycemia (r(2)=0.58), and the mean number of FGM scans, exhibited a negative correlation, while GMS (r(2)= 0.52) and the mean number of FGM scans, exhibited a positive correlation. CONCLUSION: The frequency of hypoglycemia. HbA1c level. capillary glucose, daily carbohydrates intake decreased. while the total daily insulin dose, daily bolus insulin and total GMS score increased with the use of FGM scanning for 12 weeks.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Benefits of using the Freestyle Libre flash glucose monitoring system for patients with type 1 diabetes
    Jones, A. M.
    DIABETIC MEDICINE, 2020, 37 : 64 - 65
  • [3] Evaluation of the FreeStyle® Libre Flash Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes
    Massa, Guy G.
    Gys, Inge
    Op't Eyndt, Anniek
    Bevilacqua, Esmiralda
    Wijnands, Anne
    Declercq, Peter
    Zeevaert, Renate
    HORMONE RESEARCH IN PAEDIATRICS, 2018, 89 (03): : 189 - 199
  • [4] Insulin degludec overdose in an adolescent with type 1 diabetes: proactive management including monitoring using the Freestyle Libre flash glucose monitoring system
    Thompson, Harmony
    Lunt, Helen
    Fleckney, Cate
    Soule, Steven
    ENDOCRINOLOGY DIABETES AND METABOLISM CASE REPORTS, 2018,
  • [5] Feasibility of FreeStyle Libre Flash Glucose Monitoring System in pregnant woman affected by type 1 diabetes
    Milo Gatti
    Acta Diabetologica, 2019, 56 : 481 - 483
  • [6] Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus
    Fokkert, M. J.
    van Dijk, P. R.
    Edens, M. A.
    Abbes, S.
    de Jong, D.
    Slingerland, R. J.
    Bilo, H. J. G.
    BMJ OPEN DIABETES RESEARCH & CARE, 2017, 5 (01):
  • [7] ACCEPTABILITY OF THE FREESTYLE LIBRE FLASH GLUCOSE MONITORING SYSTEM: THE EXPERIENCE OF YOUNG PATIENTS WITH TYPE 1 DIABETES
    Al Hayek, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A116 - A116
  • [8] Feasibility of FreeStyle Libre Flash Glucose Monitoring System in pregnant woman affected by type 1 diabetes
    Gatti, Milo
    ACTA DIABETOLOGICA, 2019, 56 (04) : 481 - 483
  • [9] Acceptability of the FreeStyle Libre Flash Glucose Monitoring System: The Experience of Young Patients With Type 1 Diabetes
    Al Hayek, Ayman A.
    Robert, Asirvatham A.
    Al Dawish, Mohamed A.
    CLINICAL MEDICINE INSIGHTS-ENDOCRINOLOGY AND DIABETES, 2020, 13
  • [10] FreeStyle Libre flash glucose monitoring system in pregnant woman with type 1 diabetes: a focus on accuracy
    Milo Gatti
    Anna Maria Letizia Amato
    Daniela Bruttomesso