Application of the FreeStyle®Libre Glucose Monitoring System in type 1 diabetes mellitus patients aged 1-4 years

被引:3
|
作者
Li, Yangshiyu [1 ]
Cao, Bingyan [2 ]
Chen, Qiong [1 ]
Du, Mengmeng [1 ]
Yan, Mingming [3 ]
Chen, Yongxing [1 ]
Wei, Haiyan [1 ]
Wu, Xue [1 ]
Cui, Yan [1 ]
Liu, Fang [1 ]
机构
[1] Zhengzhou Univ, Henan Childrens Hosp, Zhengzhou Childrens Hosp, Dept Endocrinol Genet & Metab,Childrens Hosp, Zhengzhou 450018, Peoples R China
[2] Capital Med Univ, Beijing Childrens Hosp, Natl Ctr Childrens Hlth, Dept Endocrinol Genet & Metab, Beijing, Peoples R China
[3] Zhengzhou Univ, Henan Childrens Hosp, Zhengzhou Childrens Hosp, Dept Stat & Epidemiol,Childrens Hosp, Zhengzhou, Peoples R China
关键词
blood glucose self-monitoring; child; diabetes mellitus; type; 1; personal satisfaction; RAPIDLY RISING INCIDENCE; ENDOCRINE-SOCIETY; MANAGEMENT; CHILDREN;
D O I
10.1111/pedi.13368
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background To investigate the analytical accuracy, safety performance, and user satisfaction (guardians of study participants) of the FreeStyle (R) Libre Glucose Monitoring System in the treatment of type 1 diabetes mellitus (T1DM), in children aged T1DM, aged 4 months to 4 years, were enrolled in this study. Patients wore the sensor for 14 days; sensor scans were performed immediately and at 5, 10, and 15 min after capillary blood glucose (BG) measurements to evaluate the effectiveness of the device and the lag effect. Results The consensus error grid showed that 96.40% of values fell within zone A (no clinical impact) and 3.60% within zone B (little/no clinical impact). Overall, the mean absolute relative difference (MARD) was 9.34%, and was higher in the capillary BG <4.0 mmol/L group (15.18%) than in the 4-10 mmol/L (9.63%) and >10 mmol/L (7.17%) groups. The MARD increased gradually with scanning time extension, indicating a short lag effect. Regression analysis showed that a higher BG level was associated with a greater difference in FreeStyle (R) Libre System measurements. Conclusions The use of the FreeStyle (R) Libre System in children aged 1-4 years is accurate and safe, and may be accurate down to 4 months, independent of patient characteristics.
引用
收藏
页码:604 / 610
页数:7
相关论文
共 50 条
  • [31] Cost-effectiveness of continuous glucose monitoring with FreeStyle Libre® in Brazilian insulin-treated patients with types 1 and 2 diabetes mellitus
    Bahia, Luciana
    Mello, Karla F.
    Lemos, Livia Lovato Pires
    Costa, Naiane Lima
    Mulinari, Eduardo
    Malerbi, Domingos A.
    DIABETOLOGY & METABOLIC SYNDROME, 2023, 15 (01):
  • [32] Assessing satisfaction, quality of life, and HbA1c changes in type 1 diabetes patients who are using freestyle libre glucose monitoring
    Alsahli, Majed A.
    Alalwan, Abdulaziz
    Aburisheh, Khaled H.
    Alarifi, Faisal F.
    Alshaya, Hesham M.
    Alkholaif, Abdulrahman F.
    Shadid, Abdulrahman M.
    Alsahli, Saud A.
    Alsahly, Abdullaziz A.
    Alkhalifah, Mohammed K.
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2024, 13 (06) : 2367 - 2374
  • [33] Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes
    Wen, Xiaofang
    Zeng, Nan
    Zhang, Ningbo
    Ou, Tingting
    Li, Xiaowei
    Li, Xiaoying
    Li, Wangen
    Xu, Kang
    Du, Tao
    DIABETES METABOLIC SYNDROME AND OBESITY, 2022, 15 : 3437 - 3445
  • [34] The accuracy of the FreeStyle navigator continuous glucose monitoring system in children with type 1 diabetes
    Wilson, Darrell M.
    Beck, Roy W.
    Tamborlane, William V.
    Dontchev, Mariya J.
    Kollman, Craig
    Chase, Peter
    Fox, Larry A.
    Ruedy, Katrina J.
    Tsalikian, Eva
    Weinzimer, Stuart A.
    DIABETES CARE, 2007, 30 (01) : 59 - 64
  • [35] EVALUATION OF FREESTYLE LIBRE FLASH GLUCOSE MONITORING SYSTEM ON GLYCEMIC CONTROL, HEALTH-RELATED QUALITY OF LIFE, AND FEAR OF HYPOGLYCEMIA IN PATIENTS WITH TYPE 1 DIABETES
    Al Hayek, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A147 - A147
  • [36] The relationship of A1C to mean glucose concentration as measured by the FreeStyle Navigator® continuous glucose monitoring system in adults with type 1 diabetes mellitus
    Dunn, Timothy C.
    Crouther, Nathan
    Taub, Marc B.
    DIABETES, 2008, 57 : A123 - A124
  • [37] The Potential Impact of the FreeStyle Libre Flash Glucose Monitoring System on Mental Well-Being and Treatment Satisfaction in Patients with Type 1 Diabetes: A Prospective Study
    Al Hayek, Ayman A.
    Al Dawish, Mohamed A.
    DIABETES THERAPY, 2019, 10 (04) : 1239 - 1248
  • [38] The Potential Impact of the FreeStyle Libre Flash Glucose Monitoring System on Mental Well-Being and Treatment Satisfaction in Patients with Type 1 Diabetes: A Prospective Study
    Ayman A. Al Hayek
    Mohamed A. Al Dawish
    Diabetes Therapy, 2019, 10 : 1239 - 1248
  • [39] The Influence of physical Activity on Sensor Accuracy of the Abbott Freestyle® Libre System in Patients with Type 1 Diabetes mellitus - A randomized Crossover Study
    Aberer, Felix
    Moser, Othmar
    Eckstein, Max
    Mueller, Alexander
    Birnbaumer, Philipp
    Koehler, Gerd
    Sourij, Caren
    Kojzar, Harald
    Holler, Peter
    Simi, Helmut
    Pferschy, Peter
    Dietz, Pavel
    Bracken, Richard
    Hofmann, Peter
    Sourij, Harald
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 363 - 363
  • [40] The FreeStyle Libre flash glucose monitoring system: how it has improved glycaemic control for people with type 1 diabetes in Eastern Cheshire, UK
    Yadegarfar, Ghasem
    Anderson, Simon G.
    Khawaja, Zohaib
    Cortes, Gabriela
    Leivesley, Kathryn
    Metters, Ann
    Horne, Linda
    Steele, Tom
    Heald, Adrian H.
    CARDIOVASCULAR ENDOCRINOLOGY & METABOLISM, 2020, 9 (04): : 171 - 176