Achievable dose reduction using iterative reconstruction for chest computed tomography: A systematic review

被引:48
|
作者
den Harder, Annemarlie M. [1 ]
Willemink, Martin J. [1 ]
de Ruiter, Quirina M. B. [2 ]
Schilham, Arnold M. R. [1 ]
Krestin, Gabriel P. [3 ]
Leiner, Tim [1 ]
de Jong, Pim A. [1 ]
Budde, Ricardo P. J. [3 ]
机构
[1] Univ Utrecht, Med Ctr, Dept Radiol, POB 85500,E01-132, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr, Dept Vasc Surg, NL-3508 GA Utrecht, Netherlands
[3] Erasmus MC, Dept Radiol, NL-3000 CA Rotterdam, Netherlands
关键词
Thorax; CT; Diagnostic imaging; Imaging; Three-dimensional; Respiratory tract diseases; FILTERED BACK-PROJECTION; IMAGE QUALITY ASSESSMENT; CT; ANGIOGRAPHY; OPTIMIZATION; VOLTAGE; NOISE; 3D;
D O I
10.1016/j.ejrad.2015.07.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Iterative reconstruction (IR) allows for dose reduction with maintained image quality in CT imaging. In this systematic review the reported effective dose reductions for chest CT and the effects on image quality are investigated. Methods: A systematic search in PubMed and EMBASE was performed. Primary outcome was the reported local reference and reduced effective dose and secondary outcome was the image quality with IR. Both non contrast-enhanced and enhanced studies comparing reference dose with reduced dose were included. Results: 24 studies were included. The median number of patients per study was 66 (range 23-200) with in total 1806 patients. The median reported local reference dose of contrast-enhanced chest CT with FBP was 2.6 (range 1.5-21.8) mSv. This decreased to 1.4 (range 0.4-7.3) mSv at reduced dose levels using IR. With non contrast-enhanced chest CT the dose decreased from 3.4 (range 0.7-7.8) mSv to 0.9 (range 0.1-4.5) mSv. Objective mage quality and diagnostic confidence and acceptability remained the same or improved with IR compared to FBP in most studies while data on diagnostic accuracy was limited. Conclusion: Radiation dose can be reduced to less than 2 mSv for contrast-enhanced chest CT and non contrast-enhanced chest CT is possible at a submillisievert dose using IR algorithms. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
下载
收藏
页码:2307 / 2313
页数:7
相关论文
共 50 条
  • [31] Feasibility of slice width reduction for spiral cranial computed tomography using iterative image reconstruction
    Haubenreisser, Holger
    Fink, Christian
    Nance, John W., Jr.
    Sedlmair, Martin
    Schmidt, Bernhard
    Schoenberg, Stefan O.
    Henzler, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (06) : 964 - 969
  • [32] Adaptive Statistical Iterative Reconstruction-V Versus Adaptive Statistical Iterative Reconstruction: Impact on Dose Reduction and Image Quality in Body Computed Tomography
    Gatti, Marco
    Marchisio, Filippo
    Fronda, Marco
    Rampado, Osvaldo
    Faletti, Riccardo
    Bergamasco, Laura
    Ropolo, Roberto
    Fonio, Paolo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (02) : 191 - 196
  • [34] Iterative Reconstruction Methods in Computed Tomography
    Stayman, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3992 - 3993
  • [35] Intraoperative computed tomography for orbital reconstruction: a systematic review
    Goh, E. Z.
    Bullis, S.
    Beech, N.
    Johnson, N. R.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2023, 53 (02) : 127 - 132
  • [36] Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose
    Cho, Hyun-Hae
    Lee, So Mi
    You, Sun Kyoung
    PEDIATRIC RADIOLOGY, 2020, 50 (02) : 242 - 251
  • [37] Model-based iterative reconstruction in paediatric head computed tomography: a pilot study on dose reduction in children
    Atri, Pardeep K.
    Sodhi, Kushaljit S.
    Bhatia, Anmol
    Saxena, Akshay K.
    Khandelwal, Niranjan
    Singhi, Pratibha
    POLISH JOURNAL OF RADIOLOGY, 2021, 86 : E504 - E510
  • [38] Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose
    Hyun-Hae Cho
    So Mi Lee
    Sun Kyoung You
    Pediatric Radiology, 2020, 50 : 242 - 251
  • [39] Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients
    Pontana, Francois
    Pagniez, Julien
    Flohr, Thomas
    Faivre, Jean-Baptiste
    Duhamel, Alain
    Remy, Jacques
    Remy-Jardin, Martine
    EUROPEAN RADIOLOGY, 2011, 21 (03) : 627 - 635
  • [40] Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients
    François Pontana
    Julien Pagniez
    Thomas Flohr
    Jean-Baptiste Faivre
    Alain Duhamel
    Jacques Remy
    Martine Remy-Jardin
    European Radiology, 2011, 21 : 627 - 635