Achievable dose reduction using iterative reconstruction for chest computed tomography: A systematic review

被引:48
|
作者
den Harder, Annemarlie M. [1 ]
Willemink, Martin J. [1 ]
de Ruiter, Quirina M. B. [2 ]
Schilham, Arnold M. R. [1 ]
Krestin, Gabriel P. [3 ]
Leiner, Tim [1 ]
de Jong, Pim A. [1 ]
Budde, Ricardo P. J. [3 ]
机构
[1] Univ Utrecht, Med Ctr, Dept Radiol, POB 85500,E01-132, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr, Dept Vasc Surg, NL-3508 GA Utrecht, Netherlands
[3] Erasmus MC, Dept Radiol, NL-3000 CA Rotterdam, Netherlands
关键词
Thorax; CT; Diagnostic imaging; Imaging; Three-dimensional; Respiratory tract diseases; FILTERED BACK-PROJECTION; IMAGE QUALITY ASSESSMENT; CT; ANGIOGRAPHY; OPTIMIZATION; VOLTAGE; NOISE; 3D;
D O I
10.1016/j.ejrad.2015.07.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Iterative reconstruction (IR) allows for dose reduction with maintained image quality in CT imaging. In this systematic review the reported effective dose reductions for chest CT and the effects on image quality are investigated. Methods: A systematic search in PubMed and EMBASE was performed. Primary outcome was the reported local reference and reduced effective dose and secondary outcome was the image quality with IR. Both non contrast-enhanced and enhanced studies comparing reference dose with reduced dose were included. Results: 24 studies were included. The median number of patients per study was 66 (range 23-200) with in total 1806 patients. The median reported local reference dose of contrast-enhanced chest CT with FBP was 2.6 (range 1.5-21.8) mSv. This decreased to 1.4 (range 0.4-7.3) mSv at reduced dose levels using IR. With non contrast-enhanced chest CT the dose decreased from 3.4 (range 0.7-7.8) mSv to 0.9 (range 0.1-4.5) mSv. Objective mage quality and diagnostic confidence and acceptability remained the same or improved with IR compared to FBP in most studies while data on diagnostic accuracy was limited. Conclusion: Radiation dose can be reduced to less than 2 mSv for contrast-enhanced chest CT and non contrast-enhanced chest CT is possible at a submillisievert dose using IR algorithms. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
下载
收藏
页码:2307 / 2313
页数:7
相关论文
共 50 条
  • [41] Radiation dose reduction using deep learning-based image reconstruction for a low-dose chest computed tomography protocol: a phantom study
    Jung, Yunsub
    Hur, Jin
    Han, Kyunghwa
    Imai, Yasuhiro
    Hong, Yoo Jin
    Im, Dong Jin
    Lee, Kye Ho
    Desnoyers, Melissa
    Thomsen, Brian
    Shigemasa, Risa
    Um, Kyounga
    Jang, Kyungeun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (03) : 1937 - +
  • [42] Assessing image quality and dose reduction of a new x-ray computed tomography iterative reconstruction algorithm using model observers
    Tseng, Hsin-Wu
    Fan, Jiahua
    Kupinski, Matthew A.
    Sainath, Paavana
    Hsieh, Jiang
    MEDICAL PHYSICS, 2014, 41 (07)
  • [43] Low-Dose Chest Computed Tomography With Sinogram-Affirmed Iterative Reconstruction, Iterative Reconstruction in Image Space, and Filtered Back Projection: Studies on Image Quality
    Hwang, Hye Jeon
    Seo, Joon Beom
    Lee, Hyun Joo
    Lee, Sang Min
    Kim, Eun Young
    Oh, Sang Young
    Kim, Ji-Eun
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 610 - 617
  • [44] Effects of oral contrast on dose in abdominopelvic computed tomography with pure iterative reconstruction
    Murphy, Kevin P.
    Healy, Liam J.
    Crush, Lee
    Twomey, Maria
    Moloney, Fiachra
    Sexton, Sylvia
    O'Connor, Owen J.
    Maher, Michael M.
    WORLD JOURNAL OF RADIOLOGY, 2016, 8 (09): : 809 - 815
  • [45] Dose reduction with iterative reconstruction for coronary CT angiography: a systematic review and meta-analysis
    Den Harder, Annemarie M.
    Willemink, Martin J.
    De Ruiter, Quirina M. B.
    De Jong, Pim A.
    Schilham, Arnold M. R.
    Krestin, Gabriel P.
    Leiner, Tim
    Budde, Ricardo P. J.
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058):
  • [46] Dose Reduction in Computed Tomography of the Chest: Image Quality of Iterative Reconstructions at a 50% Radiation Dose Compared to Filtered Back Projection at a 100% Radiation Dose
    May, M. S.
    Eller, A.
    Stahl, C.
    Wuest, W.
    Scharf, M.
    Hammon, M.
    Dankerl, P.
    Schlechtweg, P. M.
    Allmendinger, T.
    Sedlmair, M.
    Schmidt, B.
    Uder, M.
    Lell, M. M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (06): : 576 - 584
  • [47] Population-Based Screening Using Low-Dose Chest Computed Tomography: A Systematic Review of Health Economic Evaluations
    Carina M. Behr
    Martijn J. Oude Wolcherink
    Maarten J. IJzerman
    Rozemarijn Vliegenthart
    Hendrik Koffijberg
    PharmacoEconomics, 2023, 41 : 395 - 411
  • [48] Population-Based Screening Using Low-Dose Chest Computed Tomography: A Systematic Review of Health Economic Evaluations
    Behr, Carina M.
    Wolcherink, Martijn Oude J.
    IJzerman, Maarten J.
    Vliegenthart, Rozemarijn
    Koffijberg, Hendrik
    PHARMACOECONOMICS, 2023, 41 (04) : 395 - 411
  • [49] Reconstruction of limited computed tomography data of fuel cell components using Direct Iterative Reconstruction of Computed Tomography Trajectories
    Lange, Axel
    Kupsch, Andreas
    Hentschel, Manfred P.
    Manke, Ingo
    Kardjilov, Nikolay
    Arlt, Tobias
    Grothausmann, Roman
    JOURNAL OF POWER SOURCES, 2011, 196 (12) : 5293 - 5298
  • [50] CT dose reduction using Automatic Exposure Control and iterative reconstruction: A chest paediatric phantoms study
    Greffier, Jol
    Pereira, Fabricio
    Macri, Francesco
    Beregi, Jean-Paul
    Larbi, Ahmed
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (04): : 582 - 589