Achievable dose reduction using iterative reconstruction for chest computed tomography: A systematic review

被引:48
|
作者
den Harder, Annemarlie M. [1 ]
Willemink, Martin J. [1 ]
de Ruiter, Quirina M. B. [2 ]
Schilham, Arnold M. R. [1 ]
Krestin, Gabriel P. [3 ]
Leiner, Tim [1 ]
de Jong, Pim A. [1 ]
Budde, Ricardo P. J. [3 ]
机构
[1] Univ Utrecht, Med Ctr, Dept Radiol, POB 85500,E01-132, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr, Dept Vasc Surg, NL-3508 GA Utrecht, Netherlands
[3] Erasmus MC, Dept Radiol, NL-3000 CA Rotterdam, Netherlands
关键词
Thorax; CT; Diagnostic imaging; Imaging; Three-dimensional; Respiratory tract diseases; FILTERED BACK-PROJECTION; IMAGE QUALITY ASSESSMENT; CT; ANGIOGRAPHY; OPTIMIZATION; VOLTAGE; NOISE; 3D;
D O I
10.1016/j.ejrad.2015.07.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Iterative reconstruction (IR) allows for dose reduction with maintained image quality in CT imaging. In this systematic review the reported effective dose reductions for chest CT and the effects on image quality are investigated. Methods: A systematic search in PubMed and EMBASE was performed. Primary outcome was the reported local reference and reduced effective dose and secondary outcome was the image quality with IR. Both non contrast-enhanced and enhanced studies comparing reference dose with reduced dose were included. Results: 24 studies were included. The median number of patients per study was 66 (range 23-200) with in total 1806 patients. The median reported local reference dose of contrast-enhanced chest CT with FBP was 2.6 (range 1.5-21.8) mSv. This decreased to 1.4 (range 0.4-7.3) mSv at reduced dose levels using IR. With non contrast-enhanced chest CT the dose decreased from 3.4 (range 0.7-7.8) mSv to 0.9 (range 0.1-4.5) mSv. Objective mage quality and diagnostic confidence and acceptability remained the same or improved with IR compared to FBP in most studies while data on diagnostic accuracy was limited. Conclusion: Radiation dose can be reduced to less than 2 mSv for contrast-enhanced chest CT and non contrast-enhanced chest CT is possible at a submillisievert dose using IR algorithms. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
下载
收藏
页码:2307 / 2313
页数:7
相关论文
共 50 条
  • [21] Dose reduction for chest CT: comparison of two iterative reconstruction techniques
    Pourjabbar, Sarvenaz
    Singh, Sarabjeet
    Kulkarni, Naveen
    Muse, Victorine
    Digumarthy, Subba R.
    Deedar, Ranish
    Khawaja, Ali
    Padole, Atul
    Do, Synho
    Kalra, Mannudeep K.
    ACTA RADIOLOGICA, 2015, 56 (06) : 688 - 695
  • [22] Computed Tomography of the Head A Systematic Review on Acquisition and Reconstruction Techniques to Reduce Radiation Dose
    Dieckmeyer, Michael
    Sollmann, Nico
    Kupfer, Karina J.
    Loeffler, Maximilian T.
    Paprottka, Karolin J.
    Kirschke, Jan S.
    Baum, Thomas
    CLINICAL NEURORADIOLOGY, 2023, 33 (03) : 591 - 610
  • [23] Computed Tomography of the Spine Systematic Review on Acquisition and Reconstruction Techniques to Reduce Radiation Dose
    Dieckmeyer, Michael
    Sollmann, Nico
    Kupfer, Karina
    Loeffler, Maximilian T.
    Paprottka, Karolin J.
    Kirschke, Jan S.
    Baum, Thomas
    CLINICAL NEURORADIOLOGY, 2023, 33 (02) : 271 - 291
  • [24] Computed Tomography of the HeadA Systematic Review on Acquisition and Reconstruction Techniques to Reduce Radiation Dose
    Michael Dieckmeyer
    Nico Sollmann
    Karina Kupfer
    Maximilian T. Löffler
    Karolin J. Paprottka
    Jan S. Kirschke
    Thomas Baum
    Clinical Neuroradiology, 2023, 33 : 591 - 610
  • [25] Reducing the radiation dose for computed tomography colonography using model-based iterative reconstruction
    Patrick J. Millerd
    Robert G. Paden
    Jeffrey T. Lund
    Amy K. Hara
    Wendy L. Stiles
    Miao He
    Qing Wu
    C. Daniel Johnson
    Abdominal Imaging, 2015, 40 : 1183 - 1189
  • [26] Detectability of pancreatic lesions by low-dose unenhanced computed tomography using iterative reconstruction
    Sugawara, Haruto
    Yoshikawa, Takeharu
    Kunimatsu, Akira
    Akai, Hiroyuki
    Yasaka, Koichiro
    Abe, Osamu
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 141
  • [27] Reducing the radiation dose for computed tomography colonography using model-based iterative reconstruction
    Millerd, Patrick J.
    Paden, Robert G.
    Lund, Jeffrey T.
    Hara, Amy K.
    Stiles, Wendy L.
    He, Miao
    Wu, Qing
    Johnson, C. Daniel
    ABDOMINAL IMAGING, 2015, 40 (05): : 1183 - 1189
  • [28] Noise Reduction in Abdominal Computed Tomography Applying Iterative Reconstruction (ADMIRE)
    Schaller, Frank
    Sedlmair, Martin
    Raupach, Rainer
    Uder, Michael
    Leii, Michael
    ACADEMIC RADIOLOGY, 2016, 23 (10) : 1230 - 1238
  • [29] Tube current reduction and iterative image reconstruction for computed tomography myelography
    Karolin J. Paprottka
    Vivian Schultz
    Karina Kupfer
    Meinrad Beer
    Claus Zimmer
    Jan S. Kirschke
    Thomas Baum
    Nico Sollmann
    Scientific Reports, 14 (1)
  • [30] Extension of Axial Coverage and Artifact Reduction in Iterative Reconstruction in Computed Tomography
    Zamyatin, Alexander A.
    Shi, Daxin
    Dinu, Mihail Petru
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4145 - 4147