Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose

被引:16
|
作者
Cho, Hyun-Hae [1 ]
Lee, So Mi [2 ]
You, Sun Kyoung [3 ]
机构
[1] Ewha Womans Univ, Dept Radiol, Mokdong Hosp, 1071 Anyangcheon Ro, Seoul 07985, South Korea
[2] Kyungpook Natl Univ, Kyungpook Natl Univ Hosp, Sch Med, Dept Radiol, Daegu, South Korea
[3] Chungnam Natl Univ Hosp, Dept Radiol, Daejeon, South Korea
关键词
Brain; Children; Computed tomography; Image quality; Iterative reconstruction; Radiation dose; FILTERED BACK-PROJECTION; ABDOMINAL CT; YOUNG-CHILDREN; PROTOCOLS; ANGIOGRAPHY; ALGORITHM; ROUTINE;
D O I
10.1007/s00247-019-04532-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Iterative reconstruction has become the standard method for reconstructing computed tomography (CT) scans and needs to be verified for adaptation. Objective To assess the image quality after adapting advanced modeled iterative reconstruction (ADMIRE) for pediatric head CT. Materials and methods We included image sets with filtered back projection reconstruction (the cFBP group, n=105) and both filtered back projection and ADMIRE reconstruction (the lower-dose group, n=109) after dose reduction. All five strength levels of ADMIRE and filtered back projection were adapted for the lower-dose group and compared with the cFBP group. Quantitative parameters including noise, signal-to-noise ratio and contrast-to-noise ratio and qualitative parameters including noise, white matter and gray matter differentiation of the supra- and infratentorial levels, sharpness, artifact, and diagnostic accuracy were also evaluated and compared with interobserver agreement. Results There was a mean dose reduction of 30.6% in CT dose index volume, 32.1% in dose length product, and 32.1% in effective dose after tube current reduction. There was gradual reduction of noise in air, cerebrospinal fluid and white matter with strength levels of ADMIRE from 1 to 5 (P<0.001). Signal-to-noise ratio and contrast-to-noise ratio in all age groups increased among strength levels of ADMIRE, in sequence from 1 to 5, with statistical significance (P<0.001). Gradual reduction of qualitative parameters was noted among strength levels of ADMIRE in sequence from 1 to 5 (P<0.001). Conclusion Use of ADMIRE for pediatric head CT can reduce radiation dose without degrading image quality.
引用
收藏
页码:242 / 251
页数:10
相关论文
共 50 条
  • [1] Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose
    Hyun-Hae Cho
    So Mi Lee
    Sun Kyoung You
    [J]. Pediatric Radiology, 2020, 50 : 242 - 251
  • [2] Computed Tomography Radiation Dose Reduction: Effect of Different Iterative Reconstruction Algorithms on Image Quality
    Willemink, Martin J.
    Takx, Richard A. P.
    de Jong, Pim A.
    Budde, Ricardo P. J.
    Bleys, Ronald L. A. W.
    Das, Marco
    Wildberger, Joachim E.
    Prokop, Mathias
    Buls, Nico
    de Mey, Johan
    Leiner, Tim
    Schilham, Arnold M. R.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 815 - 823
  • [3] Radiation Dose Reduction in Computed Tomography: Implementation of an Iterative Image Reconstruction Method
    Chartrand-Lefebvre, Carl
    Prosmanne, Odile
    Belair, Manon
    Therasse, Eric
    [J]. CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (04): : 386 - 386
  • [4] Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom
    Ryu, Young Jin
    Choi, Young Hun
    Cheon, Jung-Eun
    Ha, Seongmin
    Kim, Woo Sun
    Kim, In-One
    [J]. PEDIATRIC RADIOLOGY, 2016, 46 (03) : 303 - 315
  • [5] Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography
    Lin Yang
    Jian Zhuang
    Meiping Huang
    Changhong Liang
    Hui Liu
    [J]. Pediatric Radiology, 2017, 47 : 31 - 38
  • [6] Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom
    Young Jin Ryu
    Young Hun Choi
    Jung-Eun Cheon
    Seongmin Ha
    Woo Sun Kim
    In-One Kim
    [J]. Pediatric Radiology, 2016, 46 : 303 - 315
  • [7] Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography
    Yang, Lin
    Zhuang, Jian
    Huang, Meiping
    Liang, Changhong
    Liu, Hui
    [J]. PEDIATRIC RADIOLOGY, 2017, 47 (01) : 31 - 38
  • [8] Noise reduction and image quality in ultra-high resolution computed tomography of the temporal bone using advanced modeled iterative reconstruction
    Hempel, Johann-Martin
    Bongers, Malte Niklas
    Braun, Katharina
    Ernemann, Ulrike
    Bier, Georg
    [J]. ACTA RADIOLOGICA, 2019, 60 (09) : 1135 - 1143
  • [9] Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography
    Sato, Jiro
    Akahane, Masaaki
    Inano, Sachiko
    Terasaki, Mariko
    Akai, Hiroyuki
    Katsura, Masaki
    Matsuda, Izuru
    Kunimatsu, Akira
    Ohtomo, Kuni
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2012, 30 (02) : 146 - 153
  • [10] Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography
    Jiro Sato
    Masaaki Akahane
    Sachiko Inano
    Mariko Terasaki
    Hiroyuki Akai
    Masaki Katsura
    Izuru Matsuda
    Akira Kunimatsu
    Kuni Ohtomo
    [J]. Japanese Journal of Radiology, 2012, 30 : 146 - 153