Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose

被引:17
|
作者
Cho, Hyun-Hae [1 ]
Lee, So Mi [2 ]
You, Sun Kyoung [3 ]
机构
[1] Ewha Womans Univ, Dept Radiol, Mokdong Hosp, 1071 Anyangcheon Ro, Seoul 07985, South Korea
[2] Kyungpook Natl Univ, Kyungpook Natl Univ Hosp, Sch Med, Dept Radiol, Daegu, South Korea
[3] Chungnam Natl Univ Hosp, Dept Radiol, Daejeon, South Korea
关键词
Brain; Children; Computed tomography; Image quality; Iterative reconstruction; Radiation dose; FILTERED BACK-PROJECTION; ABDOMINAL CT; YOUNG-CHILDREN; PROTOCOLS; ANGIOGRAPHY; ALGORITHM; ROUTINE;
D O I
10.1007/s00247-019-04532-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Iterative reconstruction has become the standard method for reconstructing computed tomography (CT) scans and needs to be verified for adaptation. Objective To assess the image quality after adapting advanced modeled iterative reconstruction (ADMIRE) for pediatric head CT. Materials and methods We included image sets with filtered back projection reconstruction (the cFBP group, n=105) and both filtered back projection and ADMIRE reconstruction (the lower-dose group, n=109) after dose reduction. All five strength levels of ADMIRE and filtered back projection were adapted for the lower-dose group and compared with the cFBP group. Quantitative parameters including noise, signal-to-noise ratio and contrast-to-noise ratio and qualitative parameters including noise, white matter and gray matter differentiation of the supra- and infratentorial levels, sharpness, artifact, and diagnostic accuracy were also evaluated and compared with interobserver agreement. Results There was a mean dose reduction of 30.6% in CT dose index volume, 32.1% in dose length product, and 32.1% in effective dose after tube current reduction. There was gradual reduction of noise in air, cerebrospinal fluid and white matter with strength levels of ADMIRE from 1 to 5 (P<0.001). Signal-to-noise ratio and contrast-to-noise ratio in all age groups increased among strength levels of ADMIRE, in sequence from 1 to 5, with statistical significance (P<0.001). Gradual reduction of qualitative parameters was noted among strength levels of ADMIRE in sequence from 1 to 5 (P<0.001). Conclusion Use of ADMIRE for pediatric head CT can reduce radiation dose without degrading image quality.
引用
收藏
页码:242 / 251
页数:10
相关论文
共 50 条
  • [31] Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique
    Kim, Jun-Hwee
    Kim, Myung-Joon
    Kim, Ha Yan
    Lee, Mi-Jung
    [J]. CLINICAL IMAGING, 2014, 38 (05) : 710 - 714
  • [32] Image quality in coronary computed tomography angiography: influence of adaptive statistical iterative reconstruction at various radiation dose levels
    Precht, Helle
    Gerke, Oke
    Thygesen, Jesper
    Egstrup, Kenneth
    Auscher, Soren
    Waaler, Dag
    Lambrechtsen, Jess
    [J]. ACTA RADIOLOGICA, 2018, 59 (10) : 1194 - 1202
  • [33] Impact of Iterative Reconstruction Algorithms on Image Quality and Radiation Dose in Computed Tomography Scan of Patients with Malignant Pancreatic Lesions
    Asemanrafat, Mohamadhosein
    Chaparian, Ali
    Lotfi, Mehrzad
    Rasekhi, Alireza
    [J]. JOURNAL OF MEDICAL SIGNALS & SENSORS, 2022, 12 (01): : 69 - 75
  • [34] A qualitative and quantitative analysis of radiation dose and image quality of computed tomography images using adaptive statistical iterative reconstruction
    Hussain, Fahad Ahmed
    Mail, Noor
    Shamy, Abdulrahman M.
    Alghamdi, Suliman
    Saoudi, Abdelhamid
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 419 - 432
  • [35] Radiation dose reduction for musculoskeletal computed tomography of the pelvis with preserved image quality
    Zabak, Elaina
    Omar, Hythem
    Boothe, Ethan
    Tenorio, Lulu
    Guild, Jeffrey
    Abbara, Suhny
    Chhabra, Avneesh
    [J]. SKELETAL RADIOLOGY, 2019, 48 (03) : 375 - 385
  • [36] Radiation dose reduction for musculoskeletal computed tomography of the pelvis with preserved image quality
    Elaina Zabak
    Hythem Omar
    Ethan Boothe
    Lulu Tenorio
    Jeffrey Guild
    Suhny Abbara
    Avneesh Chhabra
    [J]. Skeletal Radiology, 2019, 48 : 375 - 385
  • [37] Effect of the forward-projected model-based iterative reconstruction solution algorithm on image quality and radiation dose in pediatric cardiac computed tomography
    Yukako Nishiyama
    Keiji Tada
    Yuichi Nishiyama
    Hiroshi Mori
    Mitsunari Maruyama
    Takashi Katsube
    Nobuko Yamamoto
    Hidekazu Kanayama
    Yasushi Yamamoto
    Hajime Kitagaki
    [J]. Pediatric Radiology, 2016, 46 : 1663 - 1670
  • [38] Effect of the forward-projected model-based iterative reconstruction solution algorithm on image quality and radiation dose in pediatric cardiac computed tomography
    Nishiyama, Yukako
    Tada, Keiji
    Nishiyama, Yuichi
    Mori, Hiroshi
    Maruyama, Mitsunari
    Katsube, Takashi
    Yamamoto, Nobuko
    Kanayama, Hidekazu
    Yamamoto, Yasushi
    Kitagaki, Hajime
    [J]. PEDIATRIC RADIOLOGY, 2016, 46 (12) : 1663 - 1670
  • [39] Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction
    Hosch, Waldemar
    Stiller, Wolfram
    Mueller, Dirk
    Gitsioudis, Gitsios
    Welzel, Johanna
    Dadrich, Monika
    Buss, Sebastian J.
    Giannitsis, Evangelos
    Kauczor, Hans U.
    Katus, Hugo A.
    Korosoglou, Grigorios
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3568 - 3576
  • [40] Optimizing dose and image quality in pediatric computed tomography
    Jones, A.
    Huston, A.
    Falkenstien, P.
    Williams, J.
    Staton, R.
    Hintenlang, D.
    Arreola, M.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2002 - 2002