Radiation dose reduction for musculoskeletal computed tomography of the pelvis with preserved image quality

被引:2
|
作者
Zabak, Elaina [1 ]
Omar, Hythem [1 ]
Boothe, Ethan [1 ]
Tenorio, Lulu [1 ]
Guild, Jeffrey [1 ]
Abbara, Suhny [1 ]
Chhabra, Avneesh [1 ]
机构
[1] UT Southwestern Med Ctr, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
关键词
Radiation dose reduction; Computed tomography; CT; Pelvis; Musculoskeletal; TUBE VOLTAGE; ANGIOGRAPHY; CT; SELECTION;
D O I
10.1007/s00256-018-3039-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveTo analyze the impact of pelvic computed tomography (CT) technique optimization on estimated dose and subjective and objective image quality. Materials and methods: An institutional review board (IRB)-approved retrospective records review was performed with waived informed consent. Five CT scanners (various manufacturers/models) were standardized to match the lowest dose profile on campus via subjective assessment of clinical images by experienced musculoskeletal radiologists. The lowest dose profile had previously been established through image assessment by experienced musculoskeletal radiologists after a department-wide radiation dose reduction initiative. A consecutive series of 60 pre- and 59 post-optimization bony pelvis CTs were analyzed by two residents, who obtained signal-to-noise ratio for femoral cortex and marrow, gluteus medius muscle, and subcutaneous and visceral fat in a standardized fashion. Two blinded attending radiologists ranked image quality from poor to excellent. Results: Pre- and post-optimization subjects exhibited no difference in gender, age, or BMI (p>0.2). Mean CT dose index (CTDIvol) and dose-length product (DLP) decreased by approximately 45%, from 3914 to 18 +/- 12mGy (p<0.0001) and 1,227 +/- 469 to 546 +/- 384mGy-cm (p<0.0001). Lower body mass index (BMI) was associated with a larger dose reduction and higher BMI with higher DLP regardless of pre- or post-optimization examination. Inter-observer agreement was 0.64-0.92 for SNR measurements. Cortex SNR increased significantly for both observers (p<0.02). Although qualitative image quality significantly decreased for one observer (p<0.01), adequate mean quality (3.3 out of 5) was maintained for both observers. Conclusion: Subjective and objective image quality for pelvic CT examination remains adequate, despite a substantially reduced radiation dose.
引用
收藏
页码:375 / 385
页数:11
相关论文
共 50 条
  • [1] Radiation dose reduction for musculoskeletal computed tomography of the pelvis with preserved image quality
    Elaina Zabak
    Hythem Omar
    Ethan Boothe
    Lulu Tenorio
    Jeffrey Guild
    Suhny Abbara
    Avneesh Chhabra
    [J]. Skeletal Radiology, 2019, 48 : 375 - 385
  • [2] Image Quality in Computed Tomography Coronary Angiography and Radiation Dose Reduction
    Golubickas, Domas
    Lukosevicius, Saulius
    Tamakauskas, Vytenis
    Dobrovolskiene, Laima
    Baseviciene, Ingrida
    Grib, Liviu
    Ragaisyte, Nijole
    Leonavicius, Rytis
    Medvedev, Viktor
    Veikutis, Vincentas
    [J]. INFORMATICA, 2021, 32 (04) : 741 - 757
  • [3] Radiation dose and image quality in computed tomography
    Prokop, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (05): : 631 - 636
  • [4] Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality
    Geryes, Bouchra Habib
    Calmon, Raphael
    Khraiche, Diala
    Boddaert, Nathalie
    Bonnet, Damien
    Raimondi, Francesca
    [J]. EUROPEAN RADIOLOGY, 2016, 26 (07) : 2030 - 2038
  • [5] Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality
    Bouchra Habib Geryes
    Raphael Calmon
    Diala Khraiche
    Nathalie Boddaert
    Damien Bonnet
    Francesca Raimondi
    [J]. European Radiology, 2016, 26 : 2030 - 2038
  • [6] Assessment of Radiation Dose and Image Quality of Multidetector Computed Tomography
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Abdelrahman, Mostafa
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    [J]. IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [7] Radiation Dose and Image Quality in Adult Computed Tomography Scans
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Theeb, Mostafa Abdelrahman
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (02) : 223 - 231
  • [8] Computed Tomography Radiation Dose Reduction: Effect of Different Iterative Reconstruction Algorithms on Image Quality
    Willemink, Martin J.
    Takx, Richard A. P.
    de Jong, Pim A.
    Budde, Ricardo P. J.
    Bleys, Ronald L. A. W.
    Das, Marco
    Wildberger, Joachim E.
    Prokop, Mathias
    Buls, Nico
    de Mey, Johan
    Leiner, Tim
    Schilham, Arnold M. R.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 815 - 823
  • [9] Low-dose abdominopelvic computed tomography in patients with lymphoma: An image quality and radiation dose reduction study
    Yoon, Sungjin
    Yoo, Kwai Han
    Park, So Hyun
    Kim, Hawk
    Lee, Jae Hoon
    Park, Jinny
    Park, Seong Ho
    Kim, Hwa Jung
    [J]. PLOS ONE, 2022, 17 (08):
  • [10] ABDOMEN-PELVIS COMPUTED TOMOGRAPHY PROTOCOL OPTIMIZATION: AN IMAGE QUALITY AND DOSE ASSESSMENT
    Pelegrino Bastos Maues, Nadine Helena
    Fattori Alves, Allan Felipe
    Menegatti Pavan, Ana Luiza
    Ribeiro, Sergio Marrone
    Yamashita, Seizo
    Trindade, Andre Petean
    Mascarenhas, Yvone Maria
    Nicolucci, Patricia
    de Pina, Diana Rodrigues
    [J]. RADIATION PROTECTION DOSIMETRY, 2019, 184 (01) : 66 - 72