On-line corrections using a cone-beam CT for extracranial stereotactic treatments

被引:0
|
作者
Casamassima, F. [1 ]
Masi, L. [1 ]
Polli, C. [1 ]
机构
[1] Univ Florence, UO Radiobiol Clin, Florence, Italy
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
545
引用
收藏
页码:S226 / S226
页数:1
相关论文
共 50 条
  • [1] On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT)
    Bak, Jino
    Jeong, Kyoungkeun
    Keum, Ki Chang
    Park, Suk Won
    [J]. RADIATION ONCOLOGY JOURNAL, 2006, 24 (04): : 294 - 299
  • [2] Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors
    Guckenberger, Matthias
    Meyer, Juergen
    Wilbert, Juergen
    Baier, Kurt
    Mueller, Gerd
    Wulf, Joern
    Flentje, Michael
    [J]. ACTA ONCOLOGICA, 2006, 45 (07) : 897 - 906
  • [3] Image Guided Stereotactic Body Radiotherapy for Lung Cancer Using 4D Treatment Planning and On-line Cone-beam CT
    Wong, T. P.
    Rao, M.
    Cao, D.
    Ye, J.
    Shepard, D.
    Mehta, V.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S690 - S690
  • [4] STEREOTACTIC TREATMENT OF lUNG MALIGNANCIES GUIDED BY CONE-BEAM CT
    Casamassima, F.
    Masi, L.
    Polli, C.
    Bonucci, I.
    Menichelli, C.
    D'Imporzano, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S291 - S291
  • [5] Integration of cone-beam CT in stereotactic body radiation therapy
    Yin, Fang-Fang
    Wang, Zhiheng
    Yoo, Sua
    Wu, Q. Jackie
    Kirkpatrick, John
    Larrier, Nicole
    Meyer, Jeffrey
    Willett, Christopher G.
    Marks, Lawrence B.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2008, 7 (02) : 133 - 139
  • [6] Stereotactic Cone-Beam CT Guided Radiosurgery of Trigeminal Neuralgia
    Ziemer, B.
    Natsuaki, Y.
    Perez-Andujar, A.
    Morin, O.
    Weethee, B.
    Ma, L.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E658 - E659
  • [7] Stereotactic registration using cone-beam computed tomography
    Carlson, Jonathan Dennis
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 182 : 107 - 111
  • [8] Stereotactic radiosurgery for intradural spine tumors using cone-beam CT image guidance
    Monserrate, Andres
    Zussman, Benjamin
    Ozpinar, Alp
    Niranjan, Ajay
    Flickinger, John C.
    Gerszten, Peter C.
    [J]. NEUROSURGICAL FOCUS, 2017, 42 (01)
  • [9] Accuracy of stereotactic ultrasound (BAT®) for prostate repositioning-A 3D on-line fiducial based assessment with cone-beam CT
    Boda-Heggemann, J.
    Koehler, F.
    Wertz, H.
    Mennemeyer, P.
    Loeb, I.
    Mai, S.
    Hesser, J.
    Lohr, F.
    Wenz, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S731 - S731
  • [10] A New Cone-Beam CT Daily QA Phantom for Stereotactic Radiosurgery
    Zhao, Z.
    Duvvuri, S.
    Flampouri, S.
    Horne, D.
    Huh, S.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)