On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT)

被引:0
|
作者
Bak, Jino [1 ]
Jeong, Kyoungkeun [2 ]
Keum, Ki Chang [2 ]
Park, Suk Won [1 ]
机构
[1] Chung Ang Univ, Coll Med, Dept Radiat Oncol, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Seoul, South Korea
来源
RADIATION ONCOLOGY JOURNAL | 2006年 / 24卷 / 04期
关键词
IGRT; CBCT; Set-up error;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. Materials and Methods: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). Resutts: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, |n the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. Conclusion: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the an-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.
引用
收藏
页码:294 / 299
页数:6
相关论文
共 50 条
  • [1] Image-guided radiation therapy (RT) for rectal cancer using cone beam CT (CBCT)
    Lee, P.
    Xing, L.
    Pawlicki, T.
    Tran, P. T.
    Koong, A.
    Goodman, K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S276 - S276
  • [2] Clinical implementation of cone-beam CT for image-guided radiation therapy
    Zhu, X. R.
    Zhang, L.
    Kudchadker, R.
    Wu, R.
    Balter, P.
    Mohan, R.
    Gillin, M.
    Dong, L.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2268 - 2268
  • [3] Cone-beam computed tomography (CBCT) for adaptive image guided head and neck radiation therapy
    Hvid, Christian A.
    Elstrom, Ulrik V.
    Jensen, Kenneth
    Grau, Cai
    [J]. ACTA ONCOLOGICA, 2018, 57 (04) : 552 - 556
  • [4] Cone-beam-CT guided radiation therapy:: A model for on-line application
    Oldham, M
    Létourneau, D
    Watt, L
    Hugo, G
    Yan, D
    Lockman, D
    Kim, LH
    Chen, PY
    Martinez, A
    Wong, JW
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 75 (03) : 271 - 278
  • [5] Cone-Beam CT Frequency in Image Guided Radiation Therapy of Pancreatic Cancer Patients
    Zhou, J.
    Lasio, G.
    Gopal, A.
    D'Souza, W.
    Prado, K.
    Yi, B.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3052 - 3052
  • [6] Kilo-voltage cone-beam CT for image-guided radiation therapy
    Sonke, JJ
    Remeijer, P
    Betgen, A
    Lebesque, J
    van Herk, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S70 - S70
  • [7] Using Megavoltage Cone Beam CT (MV CBCT) in Image-guided Radiation Therapy for Head and Neck Cancer
    Zumsteg, Z.
    DeMarco, J.
    Lee, S. P.
    Steinberg, M. L.
    Singhvi, M.
    Lin, C. S.
    Julliard, G.
    McBride, W.
    Lin, K.
    Lee, P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S628 - S628
  • [8] Dose-guided radiation therapy with megavoltage cone-beam CT
    Chen, J.
    Morin, O.
    Aubin, M.
    Bucci, M. K.
    Chuang, C. F.
    Pouliot, J.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2006, 79 : S87 - S98
  • [9] Investigation of cone-beam CT image quality trade-off for image-guided radiation therapy
    Bian, Junguo
    Sharp, Gregory C.
    Park, Yang-Kyun
    Ouyang, Jinsong
    Bortfeld, Thomas
    El Fakhri, Georges
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (09): : 3317 - 3346
  • [10] Stopping Power Map Estimation From Cone-Beam CT Using Deep Learning for CBCT-Guided Adaptive Radiation Therapy
    Harms, J.
    Lei, Y.
    Wang, T.
    Ghavidel, B.
    Stokes, W.
    Liu, T.
    Curran, W.
    Zhou, J.
    McDonald, M.
    Yang, X.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E476 - E476